36,000 BTU 230V Ductless Mini Split AC Light Commercial Universal Floor/Ceiling Console Heat Pump

Cooper & Hunter

CH-RSH36LCFC/CH-R36LCU-230VO-no kit
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 20
WiFi Included
Zone Single Zone
Type Universal Floor/Ceiling
Freon R454B
Compressor Inverter
$3,565.44
Shipping calculated at checkout.
Optional Installation Kit: NO KIT INCLUDED

Pickup available at 3550 Northwest 113th Court

Usually ready in 2-4 days

Optional Installation Kit
Discount Banner
TrustScore 4.8

Universal Floor Ceiling

Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.

Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.

Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.

Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features

Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

An outdoor air conditioning unit designed for high performance in extreme hot and cold weather.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Cooling (Btu/h) 18,000 24,000 36,000 48,000 54,000
Rated Capacity Heating (Btu/h) 20,000 24,000 38,000 50,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 47/43.5/40.5 51/47/42 51.5/48.0/40.5 55/49.5/44.5 55/48/42
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
Indoor Packing (WxDxH) (inch) 45.08x29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature Cooling (°F) 62~90 62~90 62~90 62~90 62~90
Room Temperature Heating (°F) 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS REGULAR

Outdoor Model CH-ES18-230V0 CH-ES24-230V0 CH-N36LCU-230V0 CH-N48LCU-230V0 CH-N60LCU-230V0
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Power Supply Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity Range (Btu/h) 6,200~18,000 7,700~25,500 11,476~36,000 15,861~48,000 15,000~54,000
Cooling Rated Current (A) 6.29 8.78 19.09 23.6 24.10
Cooling EER2 (Btu/h) 12.5 12.5 8.5 9.3 9.8
Cooling SEER2 (Btu/h) 23 21.2 19 18.9 19.8
Heating at 47°F Rated Capacity Range (Btu/h) 8,100~20,000 11,600~30,900 11,467~38,000 12,159~50,000 17,000~60,000
Heating at 47°F Rated current (A) 8.51 8.77 18.04 25.5 25.5
Heating at 47°F COP (W/W) 2.92 3.66 2.68 2.5 3.03
Heating at 47°F HSPF4 (아) 10 10.3 9 10 9
Heating at 47°F HSPF5 7.7 7.8 7 7.5 7
Minimum Circuit Ampacity (A) 19 23 30 36.5 39
Max.Fuse (Outdoor Unit) (A) 30 30 45 50 50
Outdoor Air Flow (Max.) (CFM) 2,059 2,235 3,000 4,500 2,647
Outdoor Noise Level (Sound Pressure) (dB(A)) 60 61 65 63.5 64
Dimension (WxDxH) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 39.17x15.67x29.13 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs.) 94.36/100.97 124.78/134.92 155.42/166.23 219.14/249.12 217.15/248.24
Refrigerant Type / Charge (oz.) R410A/56.44 R410A/82.89 R410A/113 R410A/159 R410A/169.3
Refrigerant Precharge Length (ft) 25 25 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.32 0.32 0.32 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"
Max. Pipe Length (ft.) 98.42 164.04 213.25 213.25 213.25
Max. Difference in Level (ft.) 65.62 82.02 98.42 98.42 98.42
Ambient Temperature Cooling (°F) -13~122 -13~122 5~122 5~122 5~122
Ambient Temperature Heating (°F) -13~75 -13~75 5~75 5~75 5~75

INDOOR MODELS HYPER

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Rated Capacity Cooling (Btu/h) 17,000 24,000 36,000 48,000 55,000
Rated Capacity Heating (Btu/h) 18,000 25,000 39,000 51,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/ 1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 45.5/43/39 51/47.5/42 52.5/48.5/42.5 55/50/44 54/47/44
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
45.08×29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature (°F) Cooling: 62~90 Cooling: 62~90 Cooling: 62~90 Cooling: 62 ~ 90 Cooling: 62~ 90
Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS HYPER

Outdoor Model CH-HPR18-230V0 CH-HPR24-230VO CH-NHPR36LCU-230V0 CH-NHPR48LCU-230V0 CH-NHPR60LCU-230V0
Power Supply Rated (V, Ph, Hz) 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Power Supply Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling - Rated Capacity Range (Btu/h) 7,800 ~ 19,900 5,400 ~ 26,800 7,780~42,100 2,150~48,000 20,000~55,000
Cooling - Rated Current (A) 8.80 9.55 17.8 24.86 27
Cooling - EER2 (Btu/h) 12.5 11.7 8.8 8.2 9
Cooling SEER2 (Btu/h) 20.5 20.5 17.6 17 17.3
Heating at 47°F - Rated Capacity Range (Btu/h) 8,600~21,500 12,500~30,500 11,500~45,700 11,800~56,300 10,200~62,000
Heating at 47°F - Rated Current (A) 10.9 9.15 19 20.6 26
Heating at 47°F - COP (W/W) 3.01 3.56 2.69 2.9 2.98
Heating at 47°F - HSPF4 9.8 11 10 9.8 10.2
Heating at 47°F - HSPF5 7.5 9 8.2 7.5 8.4
Minimum Circuit Ampacity (A) 20 25 40 40 44
Max.Fuse (Outdoor Unit) (A) 25 35 50 50 60
Outdoor Air Flow (Max.) (CFM) 1,765 2,235 4,500 4,500 4,235
Outdoor Noise Level (Sound Pressure) (dB(A)) 59 62.5 63 65 61
Dimension (W×D×H) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48 37.48x16.34x52.48
Packing (W×D×H) (inch) 39.17x15.67x29.13 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs.) 100.97/108.03 134.48/144.40 220.24/248.02 227.07/255.73 240.74/271.61
Refrigerant Type / Charge (oz.) R410A / 65.26 R410A / 91.71 R410A / 148.4 R410A / 148 R410A / 169
Refrigerant Precharge Length (ft.) 25 25 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.32 0.32 0.32 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8" /5/8" 3/8" /7/8"
Max. Pipe Length (ft.) 98.42 164.04 213.25 213.25 213.25
Max. Difference in Level (ft.) 65.62 82.02 98.42 98.42 98.42
Cooling Ambient Temperature Range (°F) -22~122 -22~122 5~122 5~122 5~122
Heating Ambient Temperature Range (°F) -22~75 -22~75 -22~75 -22~75 -22~75

Multiple Control Methods

Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo