HVAC Load Calculator: What Size Mini Split Do I Need?

At average conditions a room needs about 22 BTU of cooling per square foot: about 9,000 BTU for 400 sq ft, 12,000 BTU for 550 sq ft and 24,000 BTU for 1,100 sq ft. See how we size →

1. Your climate region

Tap your state on the map, or pick a region here.

Type your room’s area, or tap a range — we use its middle.

Fine-tune the estimate (optional)
AlabamaArizonaArkansasCaliforniaColoradoConnecticutDelawareDistrict of ColumbiaFloridaGeorgiaIdahoIllinoisIndianaIowaKansasKentuckyLouisianaMaineMarylandMassachusettsMichiganMinnesotaMississippiMissouriMontanaNebraskaNevadaNew HampshireNew JerseyNew MexicoNew YorkNorth CarolinaNorth DakotaOhioOklahomaOregonPennsylvaniaRhode IslandSouth CarolinaSouth DakotaTennesseeTexasUtahVermontVirginiaWashingtonWest VirginiaWisconsinWyoming
Region #1Region #2Region #3Region #4Region #5Our warehouses

Colours show climate regions — they set the load correction. Pins are our three warehouses.

Delivery from three US warehouses
Pick your state on the map to see your delivery time
  • Free shipping on items over $300
  • Insured freight
  • Leaves the warehouse in 1–2 business days
Delivery zones & details
Recommended capacity

—

Calculated cooling load: —
Find matching products Browse all systems for this room size
Need help? Call (855) 775-4822
* The suggested BTU values are estimates for average conditions, provided in good faith for general information. Real rooms differ: layout, windows, duct runs and local climate can change the load. For a full room-by-room load calculation, have a licensed HVAC contractor run an ACCA Manual J.

How we size a mini split

At average conditions a room needs about 22 BTU of cooling per square foot: about 9,000 BTU for 400 sq ft, 12,000 BTU for 550 sq ft and 24,000 BTU for 1,100 sq ft. The calculator adjusts this for your climate region, ceiling height, sun, insulation, people and kitchen. Average conditions mean an 8-ft ceiling, average insulation and sun, and up to two people.

Size → fits a room up to

Mini split sizeFits a room up to, at average conditions
6,000 BTUabout 250 sq ft
9,000 BTUabout 400 sq ft
12,000 BTUabout 550 sq ft
18,000 BTUabout 800 sq ft
24,000 BTUabout 1,100 sq ft
30,000 BTUabout 1,350 sq ft
36,000 BTUabout 1,650 sq ft
48,000 BTUabout 2,200 sq ft
60,000 BTUabout 2,750 sq ft

Each “up to” is the size divided by 22, rounded to 50 sq ft and never above the ENERGY STAR room-size chart, so for 18,000 BTU and up our numbers are more conservative than that chart.

The formula

Load = area × 22 × (1 + region + ceiling + sun + insulation + windows) + 600 BTU for each person over two + 4,000 BTU for a kitchen. We recommend the smallest size that covers the load.

FactorAdjustmentBasis
Climate regionRegion 1 (Florida) +10%, Region 2 (South) +5%, Regions 3–5 0%Our estimate. In cold climates heating usually sets the size (NEEP)
Ceiling height+6% for each foot above 8 ft (10 ft = +12%)Our estimate; the ENERGY STAR chart assumes 8 ft
SunStrong sun +10%, heavily shaded −10%ENERGY STAR
People+600 BTU for each person over twoENERGY STAR
Kitchen+4,000 BTUENERGY STAR
InsulationWell insulated −10% … poorly insulated +10%Our estimate
WindowsMore windows than average +10%; single pane or leaky +8%, double pane and well sealed −8%Our estimate
Glass sunroom+40%Our estimate
Heat-producing devices+3.4 BTU per wattPhysics (1 W ≈ 3.4 BTU/h)

Multi-zone systems

Size each room on its own and pick an indoor unit for it. The outdoor unit sets the limit for all rooms together.

Limits

This is an estimate, not a load calculation. For a full room-by-room calculation — and in cold climates, where heating usually sets the size — have a licensed HVAC contractor run an ACCA Manual J. Questions: (855) 775-4822.

Sources

  • ENERGY STAR, Room Air Conditioners — room-size chart and adjustments: energystar.gov
  • ACCA Manual J — the ANSI-recognized standard for residential load calculations: acca.org; equipment selection, Manual S: acca.org
  • U.S. DOE Energy Saver, Ductless Mini-Split Heat Pumps — sizing and placement of each indoor unit: energy.gov
  • U.S. DOE Building America — Manual J and S as the recommended procedures: energy.gov (PDF)
  • NEEP guide to sizing air-source heat pumps in cold climates: energy.gov (PDF)

Prepared by the MiniSplitsForLess sizing team · Last updated October 21, 2026

Top sales

Add a short description for your collections

🧮 Free, no signup

HVAC Load Calculator: What Size Mini Split Do I Need?

If you are asking yourself "what size mini split do i need", start here: at average conditions a room needs about 22 BTU per square foot. The MiniSplitsForLess HVAC Load Calculator adjusts that estimate for your climate region, ceiling height, insulation, sun exposure, people and kitchen, recommends the smallest mini split size that covers the load, and links you to single-zone or multi-zone ductless systems from Cooper & Hunter, Olmo and Bravo. See how we size.

  • ✓
    Climate-Region Adjustment
    Our hvac size calculator uses five climate regions: hot, humid regions add capacity, and in cold climates heating usually sets the size.
  • ✓
    100% Free Tool
    Use our hvac load calculator free of charge. No signup, no email gate, just instant answers.
  • ✓
    Direct Product Matching
    The ac calculator lets you jump straight to systems with the recommended BTU capacity.
  • ✓
    Mobile-Friendly
    As a complete air conditioning estimator, you can optimize your mini-split sizing from any device.

FAQ: Mini Split & HVAC Sizing

⚙️ How does the MiniSplitsForLess HVAC Load Calculator work? ›
Our free btu calculator starts from about 22 BTU per square foot at average conditions and adjusts it for your climate region, ceiling height, insulation, sun exposure, people and kitchen. You enter your room's area—no login required—and get the smallest mini split size that covers the estimated load. It acts as a quick hvac calculator, linking directly to in-stock systems of that size.
📏 Why is accurate sizing important when buying a mini-split? ›
Oversized systems short-cycle and waste energy, while undersized units struggle to keep up. Our mini split size calculator gives a quick estimate for average conditions and adjusts for key factors like ceiling height and room use—especially helpful for sunrooms or kitchens. For a full room-by-room load calculation, ask your installer for an ACCA Manual J.
🏘 Can the BTU calculator help with multi-zone mini-split systems? ›
Yes. Use the mini split btu calculator room by room to estimate the size each zone needs, and pick an indoor unit for each room. The outdoor unit sets the limit for all rooms together. Our tool points you directly to multi-zone systems in stock now.
🌤 Does the HVAC size calculator adjust for climate and ceiling height? ›
It does. You pick your climate region on the map: Florida adds about 10% and the South about 5%; in colder regions we add nothing, because there heating usually sets the size—ask your installer for a Manual J load calculation. The hvac load calculator also adds 6% for each foot of ceiling above 8 ft and adjusts for insulation and sun. For example, a poorly insulated sunroom in Florida needs more cooling than a well-insulated bedroom in Oregon.
📐 How many square feet does a 24,000 BTU mini split cool? ›
About 1,100 sq ft at average conditions (8-ft ceiling, average insulation and sun, up to two people). We size at about 22 BTU per sq ft, which is more conservative than the ENERGY STAR room-size chart. A hot climate, high ceilings, strong sun or a kitchen lower that number; for a full load calculation, ask your installer for an ACCA Manual J.
🧮 How many BTU per square foot does a mini split need? ›
About 22 BTU per square foot at average conditions: about 9,000 BTU for 400 sq ft, 12,000 BTU for 550 sq ft and 24,000 BTU for 1,100 sq ft. Add about 10% in Florida, 5% in the South, 6% for each foot of ceiling over 8 ft, 10% for strong sun, 600 BTU for each person over two and 4,000 BTU for a kitchen. It's an estimate, not a Manual J load calculation.