Cooper & Hunter 18,000 BTU 2-Zone 12k+12k Ceiling Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump | No Kit No Kit









Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Why buy this mini split from MiniSplitsForLess
- Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Complete 2-Zone System
Heat or cool 2 rooms independently from one 18000 BTU outdoor unit (12K+12K) — every zone sets its own temperature, delivered by ceiling cassette indoor units.
Inverter Efficiency — SEER2 25.1
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 25.1 on 230V — steady comfort with noticeably lower energy bills.
Right-Sized Coverage
Engineered to heat & cool up to 500–800 sq ft across 2 zones — matched capacity so you never over- or under-size the space.
1-Way Cassette
The Cooper&Hunter One Way Cassette Units redefine comfort and efficiency in heating and cooling. Designed for seamless integration into ceilings, these units are perfect for both residential and commercial spaces.
Featuring advanced airflow control, compact design, and quiet operation, they deliver exceptional performance while blending effortlessly into any interior.
Engineered with energy-saving technology, anti-corrosion coatings, and durable construction, these units ensure long-lasting reliability in diverse climates.
Experience the innovation and comfort of the Cooper&Hunter One Way Cassette Units—a smarter solution for your space.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's One Way Cassette Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
| Indoor Model | CH-06MCT1W-230VI CH-06MCT1W-W* |
CH-09MCT1W-230VI CH-09MCT1W-W* |
CH-12MCT1W-230VI CH-12MCT1W-W* |
CH-18MCT1W-230VI CH-18MCT1W-W* |
CH-09MCT1W-230VI CH-09MCT1W-W* |
CH-12MCT1W-230VI CH-12MCT1W-W* |
CH-18MCT1W-230VI CH-18MCT1W-W* |
|---|---|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Cooling Rated Capacity (Btu/h) | 6,500 | 9,000 | 12,000 | 16,700 | 9,000 | 12,000 | 18,000 |
| Heating Rated Capacity (Btu/h) | 7,100 | 10,900 | 12,500 | 20,000 | 11,000 | 12,500 | 19,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/294/258/235 | 341/294/258/235 | 352/311/282/247 | 400/351/300/207 | 341/294/258/235 | 353/312/282/247 | 400/352/300/207 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 37.5/35.5/32.5 | 37.5/35.5/31 | 38.5/37/32.5 | 44/40.5/35 | 38/36/33 | 40.5/38.5/34.5 | 44/41/34 |
| Dimension (WxDxH) (inch) | 50.31x13.19x8.98 | 50.31x13.19x8.98 | 50.31x13.19x8.98 | 50.31x13.19x8.98 | 50.31x13.19x8.98 | 50.31x13.19x8.98 | 50.31x13.19x8.98 |
| Packing (WxDxH) (inch) | 57.60x22.48x22.64 | 57.60x22.48x22.64 | 57.60x22.48x22.64 | 57.60x22.48x22.64 | 57.60x22.48x22.64 | 57.60x22.48x22.64 | 57.60x22.48x22.64 |
| Net/Gross Weight (lbs.) | 43.87/81.35 | 43.87/81.35 | 45.19/82.89 | 45.19/82.89 | 43.87/81.35 | 45.19/82.89 | 45.19/82.89 |
| Room Temperature Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room Temperature Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side / Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 2 Zone 18,000 BTU mini split cool?
The Cooper & Hunter 2 Zone 18,000 BTU system can effectively cool two rooms, providing coverage for a total of up to 850 sq ft. This makes it ideal for small to medium-sized spaces.
Can I mix different BTU sizes with the Cooper & Hunter mini split?
Yes, you can mix different BTU sizes as long as the total capacity does not exceed the 18,000 BTU limit of the Cooper & Hunter system. However, for optimal efficiency, it's best to pair similar BTU ratings.
Do all zones of the Cooper & Hunter mini split run simultaneously?
In the Cooper & Hunter 2 Zone system, you have the flexibility to operate each zone independently. This allows you to cool or heat one zone while the other remains off, enhancing energy efficiency.
What is the efficiency of the Cooper & Hunter 18,000 BTU mini split compared to multiple single-zone units?
The Cooper & Hunter 2 Zone system boasts a SEER rating of 22.9, making it highly efficient compared to running multiple single-zone units. This efficiency can lead to lower energy bills and reduced installation costs.
What are the warranty terms for the Cooper & Hunter Olmo Bravo?
The Cooper & Hunter Olmo Bravo offers a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of installation. This ensures you have peace of mind with your investment.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter 2 Zone mini split comes pre-charged with refrigerant R454B for up to 25 ft of line set. This means you can install it without needing to add extra refrigerant, simplifying the installation process.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split Sale & Clearance Deals: Discounted Heat Pumps
Sale & Clearance Mini Split Sale & Clearance Deals: Discounted Heat Pumps Live Markdowns Factory-Sealed Stock Fast Shipping Cooper&Hunter Olmo...
Small Mini Split Dimensions: Exact Wall Clearances for Tight Spaces
Measured Guide 2026 Small Mini Split Dimensions: Exact Wall Clearances for Tight Spaces When inches matter, Minisplitsforless.com delivers exact clearances...
The 60,000 BTU Reality Check: Installing a 5-Ton Mini Split in a 2,500 Sq Ft Home
Maximum Capacity Climate Control The 60,000 BTU Reality Check: Installing a 5-Ton Mini Split in a 2,500 Sq Ft Home...

































