Cooper & Hunter 2 Zone 18,000 BTU OLIVIA Ductless Mini Split AC Wall Mounted 6k+6k | No Kit No Kit










Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Olivia Wall Mount
The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor and Outdoor Hyper
| Indoor Model | CH-R06MOLVWM-115VI | CH-R09MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R33HEMLVWM-230VI |
|---|---|---|---|---|---|---|
| Power Supply Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 6,000 | 9,000 | 12,000 | 18,000 | 23,000 | 33,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 294.3/225.4/176.8/141.3/NA | 382.6/293.1/194.2/153.0/NA | 382.6/293.1/194.2/153.0/NA | 759.3/530.4/419.1/382.6/NA | 759.3/586.5/419.1/382.6/NA | 829.6/716.6/592.7/447.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 42.0/37.0/32.0/24.0/NA | 42.0/37.0/32.0/24.0/NA | 43.0/37.0/32.0/24.0/NA | 52.5/44.0/40.5/35.2/25.0 | 54.5/49.0/45.3/41.3/27.0 | 56.0/49.5/45.3/41.3/27.0 |
| Dimension (WxDxH) inch | 28.7x7.87x11.81 | 31.5x7.87x11.61 | 31.5x7.87x11.61 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Packing (WxDxH) inch | 31.10x10.63x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Net/Gross Weight lbs. | 17.64/21.35 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 3/8" / 3/4" |
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| Rated Current | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER2 | 15 | 12.5 | 13 | 12 | 12 |
| SEER2 | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Indoor and Outdoor Regular
| Indoor Model | CH-R060LVWM-115VI | CH-R09OLVWM-115VI | CH-R120LVWM-115VI | CH-RO9MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R30MELVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated | 115V, 1, 60 | 115V, 1, 60 | 115V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 370/340/265/174/- | 378/340/265/174/- | 378/340/265/174/- | 382/294/194/153/- | 382/294/194/153/- | 759/530/419/382/- | 759/586/419/382/- | 871/716/547/447/- | 871/716/547/447/- |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 44/40/35/26/- | 44/40/35/26/- | 44/40/35/26/- | 45/41/32/24/- | 45/41/32/24/- | 54/49/45/41/27 | 54/49/45/41/27 | 56/52/45/38/22 | 56/52/45/38/22 |
| Dimension (WxDxH) inch | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 45.47x12.01x16.34 | 45.47x12.01x16.34 | 49.57x11.14x14.25 | 49.57x11.14x14.25 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 3/8" / 3/4" | 3/8" / 3/4" | 3/8" / 3/4" | 3/8" / 3/4" |
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 2 Zone 18,000 BTU mini split cool?
The Cooper & Hunter 2 Zone 18,000 BTU OLIVIA ductless mini split can effectively cool up to two zones or rooms, each with up to 6,000 BTU capacity, making it suitable for spaces totaling approximately 850 sq ft.
Can I mix BTU sizes with the Cooper & Hunter mini split system?
Yes, you can mix BTU sizes in a multi-zone system, but ensure that the total BTU does not exceed the system's capacity of 18,000 BTU. The efficiency of the system can still be maintained as long as the zones are properly sized for their intended space.
Do all zones run simultaneously in the Cooper & Hunter mini split?
In the Cooper & Hunter dual zone mini split, each zone can operate independently, but they can also run simultaneously if required. This allows for customized heating or cooling based on the individual needs of each room.
What is the efficiency of the Cooper & Hunter 18k BTU compared to multiple single-zone units?
The Cooper & Hunter 2 Zone 18,000 BTU mini split boasts a SEER rating of 25.1, making it highly efficient compared to using multiple single-zone units. This efficiency translates to lower energy costs and improved climate control for larger areas.
What are the warranty terms for the Cooper & Hunter OLIVIA mini split?
The Cooper & Hunter OLIVIA ductless mini split comes with a 5-year parts warranty and a 7-year compressor warranty, provided that registration is completed within 30 days of installation.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, ensuring a hassle-free installation process. It is essential to check if your installation exceeds this length, as additional refrigerant may be required.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Splits for Older Homes Without Ductwork: The Complete 2026 Retrofit Guide
The 2026 Retrofit Guide Mini Splits for Older Homes Without Ductwork Look, I love old homes. I’ve spent more weekends...
36,000 BTU Mini Split: The Honest 3-Ton Buying Guide
Expert Buying Guide 36,000 BTU Mini Split: The Honest 3-Ton Buying Guide A few years ago, I got called out...
6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide)
2026 HVAC Guide 6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide) I used to think bigger...