Cooper & Hunter 2 Zone 18,000 BTU OLIVIA Midnight Ductless Mini Split AC Wall Mounted 6k+6k | No Kit No Kit








Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Midnight Wall Mount
The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek,
modern design with efficient heating and cooling
capabilities. They offer quiet operation,
energy-saving technology, and advanced air
filtration for improved indoor air quality. Ideal for
residential and light commercial use, these units
provide easy installation, minimal maintenance,
and reliable year-round comfort.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
INDOOR MODELS MIDNIGHT
| Indoor Model | CH-B06MOLVWM-230WI | CH-B09MOLVWM-230WI | CH-B12MOLVWM-230WI | CH-B18MOLVWM-230WI | CH-B24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-B060LVWM-115VI | CH-B090LVWM-115WI | CH-B120LVWM-115WI | CH-B09MOLVWM-230VI | CH-B12MOLVWM-230WI | CH-B18MOLVWM-230WI | CH-B24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 2 Zone 18,000 BTU system cool?
The Cooper & Hunter 2 Zone 18,000 BTU mini split system can effectively cool two rooms, with a total coverage area of up to 850 sq ft. This setup allows for flexible installation in different areas of your home.
Can I mix BTU sizes with the Cooper & Hunter mini split system?
Yes, you can mix BTU sizes with the Cooper & Hunter mini split system as long as the total BTU does not exceed the maximum capacity of the outdoor unit. For example, you could pair a 12,000 BTU indoor unit with the 18,000 BTU outdoor unit for optimal performance.
Do all zones run simultaneously in the Cooper & Hunter multi-zone system?
In the Cooper & Hunter multi-zone system, both zones can run simultaneously, allowing you to maintain different temperatures in separate areas. This flexibility is ideal for tailored comfort throughout your home.
Is it more efficient to use a multi-zone mini split like Cooper & Hunter instead of multiple single-zone units?
Using the Cooper & Hunter 2 Zone 18,000 BTU mini split system is often more efficient than multiple single-zone units due to its higher SEER rating of 22.9, which enhances energy savings. This efficiency can lead to lower utility bills while providing targeted comfort.
What warranty does the Cooper & Hunter Olivia offer?
The Cooper & Hunter Olivia mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register your unit within 30 days of purchase. This warranty ensures peace of mind and protection for your investment.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split system is pre-charged with R410A refrigerant for installations using up to 25 ft of line set. This feature simplifies the installation process, allowing for quicker setup and operation.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins?
Buyer's Guide • Cooling Systems Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins? You measured the...
How Much Square Footage Can a 24,000 BTU Mini Split Cool?
Complete Sizing Guide How Much Square Footage Can a 24,000 BTU Mini Split Cool? You’ve measured your great room. You’ve...
Dual Zone Mini Split Setups: Complete Guide and Cost Breakdown
Complete Guide (2026) Dual Zone Mini Split Setups: Complete Guide and Cost Breakdown Keeping two different rooms comfortable shouldn't mean...