Alexander L.
I’m thrilled with how 3 Zone 36,000 BTU Ducted Mini Split AC Concealed Duct 12k+12k+18k. It’s been whisper-quiet, and I couldn’t be happier with the results.
Cooper & Hunter7-Yr Warranty
| SEER | |
|---|---|
| WiFi | |
| Brand | |
| Voltage | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Out of stock right now
For the next arrival, call (855) 775-4822.
— we’ll fill in your ZIP. Used only for delivery dates and pickup.
FREE shipping to We don’t ship to .Pick up at Medley, FL ·
9400 Northwest 104th Street, Suite 150, Medley, FL 33178
Buy with Shop skips your pickup choice; Add to cart keeps it.
Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated
Answers in seconds — tap a question below
Rated 5.0 out of 5 by 3 buyers of this model.
Verified reviews first · newest first
Alexander L.
I’m thrilled with how 3 Zone 36,000 BTU Ducted Mini Split AC Concealed Duct 12k+12k+18k. It’s been whisper-quiet, and I couldn’t be happier with the results.
Luke N.
The 3-zone ducted system has been solid so far. Runs smoothly and keeps every space comfortable.
Wyatt A.
It’s amazing how 3 Zone 36,000 BTU Ducted Mini Split AC Concealed Duct 12k+12k+18k. It’s been incredibly efficient, and I couldn’t be happier with the results.
Reviews of MiniSplitsForLess as a store on Trustpilot: ordering, shipping and support.
See all 586 reviews on Trustpilot ›Reviews of MiniSplitsForLess as a store on Google: ordering, shipping and support.
Heat or cool 3 rooms independently from one 36000 BTU outdoor unit (12K+12K+18K) — every zone sets its own temperature, delivered by concealed duct indoor units.
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 20 on 230V — steady comfort with noticeably lower energy bills.
Heats & cools up to about 1,650 sq ft across 3 rooms at average conditions (about 22 BTU per sq ft).
Cooper&Hunter's Slim Duct Units offer a discreet and efficient climate control solution for residential and commercial spaces. With capacities ranging from 9,000 to 60,000 BTU and SEER2 ratings up to 20.2, these units ensure energy-efficient performance.
Their slim design allows for concealed installation in ceilings or walls, maintaining a sleek interior. Equipped with advanced inverter technology, quiet operation, and optional Wi-Fi control, Slim Duct Units provide reliable, customizable comfort while blending seamlessly into any space.
Perfect for single or multi-zone systems, they deliver powerful performance with minimal ductwork.

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Cooper&Hunter's Slim Duct Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

| Model | CH-RS18MDT-MS |
|---|---|
| Unit Dimensions (WxDxH) | 34.65 x 26.54 x 8.27 in |
| Net/Gross Weight | 54.45/66.14 lb |
| Packing Dimensions (WxDxH) | 42.13 x 28.54 x 11.02 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/1/2" |
| Noise Level (Hi/Med/Lo) | 40/39/38 dB |
| Dehumidification | 3.53 pt/h |
| Filter Dimensions | 30.2x7.47 in |
| Drain Pipe Diameter | 1" |
| Controller | wire controller + remote controller available |
| Model | CH-R36MES-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.24 x 16.14 x 31.89 in |
| Net/Gross Weight | 168.87/180.12 lb |
| Packing Dimensions (WxDxH) | 42.91 x 19.68 x 34.84 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 35 A |
| Min. Circuit Ampacity | 30.5 A |
| Copper Line Size (Liquid/Gas) | 5x1/4" - 4x3/8"+1x1/2" |
| Noise Level | 64.5 dB |
| Airflow | 2,148.4 CFM |
| Dehumidification | 2.11 pt/h |
| Model | CH-RS06-12MDT- MS |
|---|---|
| Unit Dimensions (WxDxH) | 27.56 x 19.92 x 7.87 in |
| Net/Gross Weight | 39.46/46.74 lb |
| Packing Dimensions (WxDxH) | 33.86 x 21.26 x 11.22 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" |
| Noise Level (Hi/Med/Lo) | 36/34.5/32.5 dB |
| Dehumidification | 2.66 pt/h |
| Filter Dimensions | 23.3x7.24 in |
| Drain Pipe Diameter | 1" |
| Controller | wire controller + remote controller available |
| Cooling Capacity | 36,000 BTU |
|---|---|
| SEER2 | 20 |
| Zones | 3 |
| Voltage | 230V |
| Refrigerant Type | R454B |
| Compressor | Inverter |
| WiFi | Included |
| Heating Capacity | 37,000(10,000~42,500) BTU/h |
| Cooling Capacity Range | 36,000(9,000~42,000) BTU/h |
| Operating Range (Cooling) | -13~122 °F |
| Operating Range (Heating) | -13~75 °F |
| Refrigerant Precharge | 125 ft |
| Max Height Difference | 49.2 ft |
| COP | 3.5 |
Technical specifications for every model in the series — this product is one of them.
| Indoor Model | CH-RS06MDT-MS CH-RS06-12MDT-MS (Dip Switch 6) |
CH-RS09MDT-MS CH-RS06-12MDT-MS (Dip Switch 9) |
CH-RS12MDT-MS CH-RS06-12MDT-MS (Dip Switch 12) |
CH-RS18MDT-MS | CH-RS24MDT-HS | CH-RS36LCDT-HS | CH-RS48LCDT-HS | CH-RS60LCDT-HS |
|---|---|---|---|---|---|---|---|---|
| Power Supply | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity | 6,500/8,000 | 9,000/10,000 | 12,000/12,500 | 17,000/19,000 | 24,000/26,000 | 36,000/42,000 | 48,000/52,000 | 55,000/60,000 |
| Minimum Circuit Ampacity (MCA) | 3 | 3 | 3 | 3 | 3 | 4 | 5 | 5 |
| Max. Fuse | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 323.7/264.9/206.0/147.2/117.7 | 323.7/264.9/206.0/147.2/117.7 | 400.2/323.7/264.9/176.6/117.7 | 600.4/559.2/500.3/441.4/NA | 853.5/706.3/618.0/500.3/NA | 1236.1/1059.5/941.8/766.5/NA | 1648.1/1471.5/1294.9/1059.5/NA | 2001.2/1706.9/1412.6/1118.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | NA/32.5/30.5/29.5/22 | NA/32.5/31/29.5/23 | NA/36/34.5/32.5/25.5 | NA/40/39/38/32 | NA/40/37/35/29.5 | NA/45/40/34/31 | NA/51/46/42/40 | NA/52/48/42/41 |
| Dimension (WxDxH) inch | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 34.65 x 26.54 x 8.27 | 39.37 x 29.53 x 9.65 | 47.24 x 29.53 x 11.81 | 47.24 x 29.53 x 11.81 | 55.12 x 31.50 x 14.96 |
| Packing (WxDxH) inch | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 42.13 x 28.54 x 11.02 | 48.23 x 33.86 x 11.97 | 56.10 x 33.86 x 14.13 | 56.10 x 33.86 x 14.13 | 62.99 x 36.02 x 17.52 |
| Net/Gross Weight lbs. | 39.46/46.74 | 39.46/46.74 | 39.46/46.74 | 54.45/66.14 | 80.47/91.93 | 106.26/120.37 | 111.33/124.78 | 161.38/178.13 |
| Room Temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room Temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4"/3/8" | 1/4"/3/8" | 1/4"/3/8" | 1/4"/1/2" | 3/8"/5/8" | 3/8"/3/4" | 3/8"/3/4" | 3/8"/3/4" |
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Outdoor condenser | CH-R36MES-230VO |
|---|---|
| Remote controller | wire controller + remote controller available |
Installation kit is not included in the selected option — pick 16ft, 25ft or 50ft above to add one.
7-year compressor / 5-year parts
Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
The Cooper & Hunter 3 Zone 36,000 BTU mini split is capable of cooling up to three separate rooms efficiently, making it ideal for multi-zone applications. With a coverage area of up to 1500 sq ft, it can effectively manage varying temperature needs across those spaces.
Yes, you can mix BTU sizes with the Cooper & Hunter 36,000 BTU system, allowing for combinations such as 12k, 12k, and 18k units. This flexibility helps tailor the system to your specific heating and cooling requirements across different zones.
No, not all zones need to run simultaneously with the Cooper & Hunter mini split system. Each zone can be controlled independently, allowing for energy efficiency and tailored comfort based on occupancy and usage.
Yes, with a SEER rating of 20.0, the Cooper & Hunter 36,000 BTU ducted mini split is designed to be more efficient than operating multiple single-zone units. This efficiency can result in lower energy costs and more consistent temperature control across your home.
The Cooper & Hunter 36,000 BTU mini split comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the system within 30 days of installation. This warranty ensures that you have peace of mind regarding the longevity and reliability of your investment.
Yes, the Cooper & Hunter 36,000 BTU mini split system comes pre-charged with R454B refrigerant for up to 25 ft of line set. This feature simplifies installation, ensuring optimal performance right from the start.
If you're thinking about turning your home into a smart home, you're not alone.
Ductless HVAC Basics What Is a Mini Split? Parts, How It Works & 2026 Costs Pre-Purchase Guide 2026 Edition HVAC...
2026 Cost & Sizing Guide Whole House Mini Split Systems: 2026 Costs, Zone Counts & Sizing Multi-Zone Olivia & Olivia...
2026 Buyer's Guide Cooper and Hunter Mini Split Guide 2026: Prices, Series & Specs MIA Olivia Hyper Heat 2026 Pricing...
Pick a system type to get started.