Cooper & Hunter 2 Zone 48,000 BTU OLIVIA Ductless Mini Split AC Ceiling Cassette 24k+24k

Cooper & Hunter

CH-R48MES-230VO24CT24CT
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 23.4
WiFi Not Included
Zone Dual Zone
Type Ceiling Cassette
Freon R454B
Compressor Inverter
$5,846.40
Shipping Policy calculated at checkout.

Pickup available at 3550 Northwest 113th Court

Usually ready in 2-4 days

FREE Armbridge Accessory With This Purchase

Choose one below — it will be added to your cart for free

Select your free accessory:

FREE
ARMBRIDGE AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base with Built-In Leveler
AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Zinc,...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Foldable 304 Stainless Steel, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Folda...
FREE
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity
Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets ...
FREE
ARMBRIDGE 18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, Anti-Slip Foundation for HVAC Systems and Outdoor Equipment
18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, ...
Free gift added to your cart!
Discount Banner
TrustScore 4.8

1-Way Cassette

The Cooper&Hunter One Way Cassette Units redefine comfort and efficiency in heating and cooling. Designed for seamless integration into ceilings, these units are perfect for both residential and commercial spaces.

Featuring advanced airflow control, compact design, and quiet operation, they deliver exceptional performance while blending effortlessly into any interior.

Engineered with energy-saving technology, anti-corrosion coatings, and durable construction, these units ensure long-lasting reliability in diverse climates.

Experience the innovation and comfort of the Cooper&Hunter One Way Cassette Units—a smarter solution for your space.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features

Cooper&Hunter's One Way Cassette Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

Indoor Model CH-06MCT1W-230VI
CH-06MCT1W-W*
CH-09MCT1W-230VI
CH-09MCT1W-W*
CH-12MCT1W-230VI
CH-12MCT1W-W*
CH-18MCT1W-230VI
CH-18MCT1W-W*
CH-09MCT1W-230VI
CH-09MCT1W-W*
CH-12MCT1W-230VI
CH-12MCT1W-W*
CH-18MCT1W-230VI
CH-18MCT1W-W*
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Cooling Rated Capacity (Btu/h) 6,500 9,000 12,000 16,700 9,000 12,000 18,000
Heating Rated Capacity (Btu/h) 7,100 10,900 12,500 20,000 11,000 12,500 19,000
Minimum Circuit Ampacity (MCA) (A) 3 3 3 3 3 3 3
Max. Fuse (A) 15 15 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 341/294/258/235 341/294/258/235 352/311/282/247 400/351/300/207 341/294/258/235 353/312/282/247 400/352/300/207
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 37.5/35.5/32.5 37.5/35.5/31 38.5/37/32.5 44/40.5/35 38/36/33 40.5/38.5/34.5 44/41/34
Dimension (WxDxH) (inch) 50.31x13.19x8.98 50.31x13.19x8.98 50.31x13.19x8.98 50.31x13.19x8.98 50.31x13.19x8.98 50.31x13.19x8.98 50.31x13.19x8.98
Packing (WxDxH) (inch) 57.60x22.48x22.64 57.60x22.48x22.64 57.60x22.48x22.64 57.60x22.48x22.64 57.60x22.48x22.64 57.60x22.48x22.64 57.60x22.48x22.64
Net/Gross Weight (lbs.) 43.87/81.35 43.87/81.35 45.19/82.89 45.19/82.89 43.87/81.35 45.19/82.89 45.19/82.89
Room Temperature Cooling (°F) 60~90 60~90 60~90 60~90 60~90 60~90 60~90
Room Temperature Heating (°F) 32~86 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side / Gas Side (inch) 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2"

Outdoor Regular

Specification CH-R18MES-230VO CH-R28MES-230VO CH-R36MES-230VO CH-R48MES-230VO CH-R60MES-230VO
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (range) (Btu/h) 5,400~21,600 7,200~32,000 9,000~42,000 12,000~55,000 19,000~62,000
Cooling Rated Current (A) 6 9.2 13.5 16.6 26.2
EER2 14 13 12 12.5 10
SEER2 25.1 25 24 24 22
Heating Rated Capacity (range) (Btu/h) 5,700~21,600 8,400~29,000 10,000~42,500 13,000~53,000 20,000~60,000
Heating Rated Current (A) 6.8 9.2 14 16.3 21
Heating at 47°F COP (W/W) 3.8 3.8 3.5 3.8 3.7
HSPF4 9.8 9.5 9.5 10.3 9.5
HSPF5 7.8 7 7 8 7.4
Heating at 5°F Rated Capacity (Btu/h) 13,500 19,000 26,000 36,000 39,000
Minimum Circuit Ampacity (Outdoor unit) (A) 16 23 30.5 40 40
Max. Fuse (Outdoor unit) (A) 20 25 35 45 45
Outdoor Air Flow (Max) (CFM) 1,765.8 2,130.7 2,148.4 4,502.8 4,502.8
Outdoor Noise Level (Sound Pressure) (dB(A)) 59.5 61 64.5 63 65
Dimension (W×D×H) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (W×D×H) (inch) 40.55x17.24x29.53 42.91x19.68x34.84 42.91x19.68x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs) 100.53/109.35 138.89/149.69 168.87/180.12 222.00/254.19 237.88/270.28
Refrigerant Type/Charged (oz) R454B/61.73 R454B/84.66 R454B/120.63 R454B/148.15 R454B/151.68
Refrigerant Precharge (ft) 75 100 125 150 150
Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Refrigerant Piping Gas Side (inch) 3 x 3/8" 3 x 3/8" + 1 x 1/2" 4 x 3/8" + 1 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max. Pipe Length (ft) 196.8 262.4 262.4 262.4 262.4
Max. Length for One Indoor Unit (ft) 98.4 114.8 114.8 114.8 114.8
Max. Height Difference in Level (ft) 49.2 49.2 49.2 49.2 49.2
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) -13~122 -13~122 -13~122 -13~122 -13~122
Ambient Temperature Heating (°F) -13~75 -13~75 -13~75 -13~75 -13~75
Certification: AHRI
Certification: Energy Star
Certification: NEEP
Certification: ETL

Outdoor Hyper

Specification CH-RVHP19M-230VO CH-RVHP28M-230VO CH-RVHP36M-230VO CH-RVHP48M-230VO CH-RVHP55M-230VO
Power Supply (V/Ph/Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Operating Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Capacity (BTU/h) 5,400~28,000 7,200~37,000 9,000~43,000 12,000~57,000 19,000~59,000
SEER2 5.6 9.5 12 17.3 18.5
EER 15 12.5 13 12 12
IEER 25 23 23 23 22.2
Heating Capacity (BTU/h) 5,700~27,000 8,400~36,000 10,000~44,000 13,000~57,000 20,000~59,000
HSPF2 6.5 9.1 11.5 17.3 20.1
COP 4 3.8 4 3.7 3.5
SCOP 10.4 10.5 10.7 11 10.5
Power Input (W) 8.5 8.5 8.5 9 8.5
Air Flow (CFM) 19,000 27,000 36,000 47,000 47,000
Sound Level Indoor (dBA) 17.5 30 37 37 39.5
Sound Level Outdoor (dBA) 20 35 40 40 40
Weight Indoor (lbs) 2,130.7 2,148.4 3,037.2 4,502.8 4,502.8
Weight Outdoor (lbs) 61.5 61 65 65 65
Dimensions Indoor (in) 37.24x16.14x31.89 37.24x16.14x31.89 38.58x16.34x38.39 37.48x16.34x52.48 37.48x16.34x52.48
Dimensions Outdoor (in) 42.91x19.68x34.84 42.91x19.68x34.84 45.08x19.68x42.52 43.11x19.49x58.27 43.11x19.49x58.27
Shipping Weight Indoor/Outdoor (lbs) 137.35/148.15 168.43/179.67 211.86/244.71 246.47/276.68 246.47/276.68
Refrigerant Type/Amount (lbs) R454B/78.31 R454B/120.63 R454B/134.04 R454B/151.68 R454B/151.68
Fuse Size (A) 75 100 125 150 150
Wire Size (AWG) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Control Voltage (V) 550/340 550/340 550/340 550/340 550/340
Liquid Line 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Suction Line 3 x 3/8" 3 x 3/8" + 1 x 1/2" 3 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max Line Length (ft) 196.8 262.4 262.4 262.4 262.4
Max Elevation Diff (ft) 98.4 114.8 114.8 114.8 114.8
Max Head Pressure (ft) 49.2 49.2 49.2 49.2 49.2
Max Suction Pressure (ft) 33 33 33 33 33
Operating Range Cooling (°F) -22~122 -22~122 -22~122 -22~122 -22~122
Operating Range Heating (°F) -22~75 -22~75 -22~75 -22~75 -22~75
Feature 1
Feature 2
Feature 3
Feature 4

Multiple Control Methods

Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

How many rooms can the Cooper & Hunter 2 Zone 48,000 BTU mini split cool?

The Cooper & Hunter 2 Zone 48,000 BTU OLIVIA Ductless Mini Split AC can effectively cool up to two rooms, depending on the size and insulation of each space. With a coverage area of up to 2000 sq ft, it is ideal for larger areas or open floor plans.

Can I mix BTU sizes with the Cooper & Hunter mini split system?

While the Cooper & Hunter 2 Zone 48,000 BTU system features two 24,000 BTU units, mixing BTU sizes is generally not recommended as it can affect system efficiency. It's best to use matched BTU sizes for optimal performance and efficiency.

Do all zones in the Cooper & Hunter mini split run simultaneously?

Yes, the Cooper & Hunter 2 Zone 48,000 BTU system allows both zones to operate simultaneously, providing tailored comfort for each area. However, the total BTU output should be considered to ensure sufficient cooling capacity for both zones.

Is the Cooper & Hunter 48,000 BTU mini split more efficient than multiple single-zone units?

The Cooper & Hunter 2 Zone system offers a SEER rating of 23.4, making it more efficient than operating multiple single-zone units. This efficiency can result in lower energy costs and simplified installation, especially for larger spaces.

What are the warranty terms for the Cooper & Hunter OLIVIA Ductless Mini Split?

The Cooper & Hunter OLIVIA offers a warranty that includes a 5-year parts warranty and a 7-year compressor warranty, provided you register within 30 days of purchase. This warranty ensures you have support for your system's longevity.

Does the Cooper & Hunter mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter 2 Zone 48,000 BTU mini split comes pre-charged with R454B refrigerant for up to 25 ft of line set. This feature simplifies installation, making it easier for you to set up your cooling system efficiently.