Cooper & Hunter 4 Zone 48,000 BTU OLIVIA Ductless Mini Split AC Wall Mounted 9k+12k+18k+18k










Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup currently unavailable at 3550 Northwest 113th Court
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Wall Mount
The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
INDOOR MODELS HYPER
| Indoor Model | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 48,000 BTU mini split cool?
The Cooper & Hunter 48,000 BTU OLIVIA Ductless Mini Split can effectively cool up to four rooms, depending on their size and layout. With a total coverage area of up to 2000 sq ft, this system is ideal for multi-zone applications.
Can I mix different BTU sizes in a Cooper & Hunter mini split installation?
Yes, in a Cooper & Hunter system, you can mix different BTU sizes across the zones, such as the 9k, 12k, and 18k units in this 48,000 BTU setup. This flexibility allows for tailored cooling based on the specific needs of each room.
Do all zones in the Cooper & Hunter multi-zone mini split run simultaneously?
In the Cooper & Hunter multi-zone system, each zone can be controlled independently, so they do not have to run simultaneously. This feature allows for customized comfort settings in each room while optimizing energy efficiency.
What are the advantages of a Cooper & Hunter mini split compared to multiple single-zone units?
A Cooper & Hunter mini split system, such as the 48,000 BTU model with a 23.4 SEER rating, is generally more energy-efficient than multiple single-zone units. It consolidates installation and maintenance while providing better overall climate control across multiple zones.
What is the warranty for the Cooper & Hunter OLIVIA mini split system?
The Cooper & Hunter OLIVIA mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This warranty ensures you have reliable support for your investment.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split system comes pre-charged with R410A refrigerant for installations up to 25 ft of line set. This feature simplifies installation and ensures optimal performance right out of the box.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
36,000 BTU Mini Split: The Honest 3-Ton Buying Guide
Expert Buying Guide 36,000 BTU Mini Split: The Honest 3-Ton Buying Guide A few years ago, I got called out...
6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide)
2026 HVAC Guide 6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide) I used to think bigger...
18,000 BTU Mini Split: An Installer’s No-Nonsense Sizing & Selection Guide
Installers' Guide 18,000 BTU Mini Split: Our No-Nonsense Sizing & Selection Guide We’ve been on a hundred service calls that...


































