Cooper & Hunter 4 Zone 48,000 BTU Olivia Midnight Ductless Mini Split AC Wall Mounted 6K+6K+6K+24K

Cooper & Hunter

CH-48MES-230VO06OLV24OLV
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 23.4
WiFi Included
Zone Four Zone
Type Wall Mount
Freon R410A
Compressor Inverter
$5,108.00 Sold out
Shipping Policy calculated at checkout.

Pickup currently unavailable at 3550 Northwest 113th Court

FREE Armbridge Accessory With This Purchase

Choose one below — it will be added to your cart for free

Select your free accessory:

FREE
ARMBRIDGE AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base with Built-In Leveler
AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Zinc,...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Foldable 304 Stainless Steel, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Folda...
FREE
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity
Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets ...
FREE
ARMBRIDGE 18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, Anti-Slip Foundation for HVAC Systems and Outdoor Equipment
18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, ...
Free gift added to your cart!
Hurry to buy! Get your mini-split system with R-410A refrigerant (offer valid until November 27)
Important info
  • R-410A is being phased down in favor of newer refrigerants; inventory is limited.
  • Existing R-410A systems remain serviceable; parts and qualified service are widely available.
  • Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
  • We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Discount Banner
TrustScore 4.8

Olivia Midnight Wall Mount

The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.

Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.

Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features

Cooper&Hunter's Olivia Units feature sleek,
modern design with efficient heating and cooling
capabilities. They offer quiet operation,
energy-saving technology, and advanced air
filtration for improved indoor air quality. Ideal for
residential and light commercial use, these units
provide easy installation, minimal maintenance,
and reliable year-round comfort.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

INDOOR MODELS MIDNIGHT

Indoor Model CH-B06MOLVWM-230WI CH-B09MOLVWM-230WI CH-B12MOLVWM-230WI CH-B18MOLVWM-230WI CH-B24MOLVWM-230WI
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity (Btu/h) 6,000 9,000 12,000 18,000 24,000
Minimum Circuit Ampacity (MCA) (A) 3 3 3 3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 294/247/176/141 341/291/194/152 341/291/194/152 768/530/458/382 790/601/459/382
Indoor Noise Level (Hi/Mi/Lo) dB(A) 38.5/30/20.5 40/35/23.5 41.5/36/24 46/40/25 46.5/44/35
Dimension (WxDxH) (inch) 28.70x7.87x11.30 31.57x7.87x11.61 31.57x7.87x11.61 42.64x9.61x13.23 42.68x9.21x13.27
Packing (WxDxH) (inch) 31.10x10.83x14.76 34.45x11.22x14.96 34.45x11.22x14.96 45.47x16.34x12.40 45.47x16.34x12.40
Net/Gross Weight (lbs.) 17.64/22.49 18.96/24.25 18.74/24.25 29.54/37.48 29.98/38.14
Room Temperature Cooling (°F) 60 - 90 60 - 90 60 - 90 60 - 90 60 - 90
Room Temperature Heating (°F) 32 - 86 32 - 86 32 - 86 32 - 86 32 - 86
Liquid Side/Gas Side (inch) 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 3/8" / 5/8"

INDOOR MODELS REGULAR

Indoor Model CH-B060LVWM-115VI CH-B090LVWM-115WI CH-B120LVWM-115WI CH-B09MOLVWM-230VI CH-B12MOLVWM-230WI CH-B18MOLVWM-230WI CH-B24MOLVWM-230WI
Power Supply Rated (V, Ph, Hz) 115V, 1, 60 115, 1, 60 115, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity (Btu/h) 7,000 9,000 12,000 9,000 12,000 18,000 24,000
Minimum Circuit Ampacity (MCA) (A) 3 3 3 3 3 3 3
Max. Fuse (A) 15 15 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 341/300/241/176 341/300/241/176 341/300/241/176 291.18/194.12/152.94 341/291/194/152 768/530/458/382 790/601/459/382
Indoor Noise Level (Hi/Mi/Lo) dB(A) 41.5/36/24 41.5/36/24 41.5/36/24 40/34/23.5 42/36/25 45.5/41/24.5 48/40/28
Dimension (WxDxH) (inch) 31.57x7.87x11.61 31.57x7.87x11.61 31.57x7.87x11.61 31.57x7.87x11.61 31.57x7.87x11.61 42.64x9.61x13.23 42.68x9.21x13.27
Packing (WxDxH) (inch) 34.45x11.22x14.96 34.45x11.22x14.96 34.45x11.22x14.96 34.45x11.22x14.96 34.45x11.22x14.96 45.47x16.34x12.40 45.47x16.34x12.40
Net/Gross Weight (lbs.) 18.96/24.47 18.96/24.47 18.96/24.47 18.96/24.25 18.74/24.25 29.54/37.48 29.98/38.14
Room Temperature Cooling (°F) 60 - 90 60 - 90 60 - 90 60 - 90 60 - 90 60 - 90 60 - 90
Room Temperature Heating (°F) 32 - 86 32 - 86 32 - 86 32 - 86 32 - 86 32 - 86 32 - 86
Liquid Side/Gas Side (inch) 1/4" / 1/2" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 3/8" / 5/8"

OUTDOOR MODELS REGULAR

Parameter ES-Series
CH-18MES-230V0 CH-28MES-230V0 CH-36MES-230V0 CH-48MES-230V0 CH-55MES-230V0
Power Supply (V, Ph, Hz) 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (Btu/h) 18,000(5,650~22,000) 28,000(9,838~30,438) 36,000(8,209~40,555) 48,000(19,000~50,000) 55,000(11,600-57,300)
Cooling Rated Current (A) 6.2 11 13.6 16.8 23.5
EER2 (Btu/h) 13.9 12.7 11.7 12.5 10.5
SEER2 (Btu/h) 22.9 24.6 23.9 23.4 21.3
Heating Rated Capacity (Btu/h) 19,000(5,050~24,400) 28,000(8,218-31,000) 37,000(8,008~44,632) 48,000(12,500~52,000) 55,000(12,500~63,000)
Heating Rated Current (A) 6.3 10.5 13 17.1 22.5
Heating at 47°F COP (W/W) 3.74 3.73 3.5 3.57 3.2
HSPF4 10.5 9.3 9.3 8.7 9.1
HSPF5 8 7.1 7.1 6.8 6.8
Heating at 5°F Rated Capacity (Btu/h) 12,600 19,000 25,200 33,000 32,200
Heating at 5°F COP (W/W) 2 2 1.8 1.8 1.8
Minimum Circuit Ampacity (Outdoor unit) (A) 18 24.5 25 40 40
Max. Fuse (Outdoor unit) (A) 25 30 40 60 60
Outdoor Air Flow (Max) (CFM) 1,765 2,129 2,147 4,500 4,500
Outdoor Noise Level (Sound Pressure) (dB(A)) 58 61 63 64 62
Dimension (WxDxH) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 40.55x17.24x29.53 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight 100/109 140/151 169/181 226/257 224/257
Refrigerant Type/Charged (oz) R410A/65.26 R410A/91.7 R410A/134.04 R410A/162 R410A/162
Refrigerant Precharge (ft) 49 74 98 123 123
Additional Charge for Each (oz/ft) 0.16 0.16 0.16 - *0.32 0.16 - *0.32 0.16 - *0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 2 x 1/4" 3 x 1/4" 4 x 1/4" 5 x 1/4" 5 x 1/4"
Refrigerant Piping Gas Side (inch) 2 x 3/8" 3 x 3/8" 3 x 3/8" + 1 x 1/2" 3 x 3/8" + 2 x 1/2" 3 x 3/8" + 2 x 1/2"
Max. Pipe Length (ft) 131 197 262 262 262
Max. Length for One Indoor Unit (ft) 82 98 115 115 115
Max. Height Difference in Level (ft) 49 49 49 49 49
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) 5~122 5~122 5-122 5-122 5~122
Ambient Temperature Heating (°F) -13~75 -13-75 -13~75 -13~75 -13~75
AHRI
Energy Star
NEEP

OUTDOOR MODELS HYPER

Parameter CH-HPR19M-230V0 CH-HPR28M-230V0 CH-HPR36M-230V0 CH-HPR48M-230VO CH-HPR55M-230V0
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (Btu/h) 19,000 (5,500~-25,000) 28,000(7,995-32,826) 36,000(17,900~42,000) 48,000 (19,300-51,000) 55,000(11,600~58,000)
Cooling Rated Current (A) 9.1 12.4 11.8 18 23.5
EER2 (Btu/h) 12.5 12.5 13.6 11.7 10.5
SEER2 (Btu/h) 22 23 22.2 21.8 22
Heating Rated Capacity (Btu/h) 20,000(8,100~29,700) 28,000(5,035~38,712) 36,500(12,500~49,000) 49,000(11,500~58,000) 55,000(33,000~63,000)
Heating Rated Current (A) 9.4 10.5 12.2 17.8 22.5
Heating at 47°F COP (W/W) 3.4 3.66 3.9 3.8 3.05
HSPF4 9.8 10.6 10.3 9.8 9.3
HSPF5 7.7 8.1 8.3 7.6 7.3
Heating at 5°F Rated Capacity (Btu/h) 19,000 24,000 36,000 48,000 37,800
Heating at 5°F COP (W/W) 1.96 1.75 1.9 2 1.8
Minimum Circuit Ampacity (Outdoor unit) (A) 20 25 40 42 40
Max. Fuse (Outdoor unit) (A) 25 40 60 50 60
Outdoor Air Flow (Max) (CFM) 2,129 2,147 4,500 4,500 4,500
Outdoor Noise Level (Sound Pressure) (dB(A)) 61 63 63 65 62
Dimension (WxDxH) (inch) 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight 138/149 168/179 223/254 238/270 233/266
Refrigerant Type/Charged (oz) R410A/91.7 R410A/134.04 R410A/162 R410A/162 R410A/162
Refrigerant Precharge (ft) 49 74 98 123 123
Additional Charge for Each (oz/ft) 0.16 0.16 - *0.32 0.16 - *0.32 0.16 - *0.32 0.16 -*0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 2 x 1/4" 3 x 1/4" 4 x 1/4" 5 x 1/4" 5 x 1/4"
Refrigerant Piping Gas Side (inch) 2 x 3/8" 2 x 3/8" +1 x 1/2" 3 x 3/8" +1 x 1/2" 3 x 3/8" + 2 x 1/2" 3 x 3/8" +2 x 1/2"
Max. Pipe Length (ft) 131 197 262 262 262
Max. Length for One Indoor Unit (ft) 82 98 115 115 115
Max. Height Difference in Level (ft) 49 49 49 49 49.21
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) 5~122 5~122 5~122 5~122 5~122
Ambient Temperature Heating (°F) -22~75 -22~75 -22~75 -22~75 -22~75

Multiple Control Methods

Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

How many rooms can the Cooper & Hunter 48,000 BTU mini split cool?

The Cooper & Hunter 4 Zone 48,000 BTU mini split can effectively cool up to four separate rooms, making it ideal for larger spaces or multi-room setups. With a coverage area of up to 2000 sq ft, it ensures optimal comfort throughout your home.

Can I mix different BTU sizes with the Cooper & Hunter mini split system?

Yes, you can mix different BTU sizes in a multi-zone setup, but it's essential to ensure that the total BTU does not exceed the system's capacity. The Cooper & Hunter system allows for a combination of 6K, 6K, 6K, and 24K BTU units, providing flexibility for various room sizes.

Do all zones in the Cooper & Hunter multi-zone system run simultaneously?

No, in the Cooper & Hunter multi-zone system, you can control each zone independently, allowing you to cool or heat only the rooms that are in use. This feature enhances energy efficiency, particularly with a SEER rating of 23.4.

Is the Cooper & Hunter mini split more efficient than using multiple single-zone units?

Yes, the Cooper & Hunter 48,000 BTU mini split with a SEER rating of 23.4 offers higher energy efficiency compared to multiple single-zone units. This means lower energy bills and reduced environmental impact while providing comfort across multiple rooms.

What are the warranty terms for the Cooper & Hunter 48,000 BTU system?

The Cooper & Hunter mini split system comes with a comprehensive warranty: a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This ensures peace of mind for your investment.

Does the Cooper & Hunter mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter mini split system comes pre-charged with R410A refrigerant for up to 25 ft of line set. This means you can install it with minimal hassle, as it’s ready to operate right out of the box.