Cooper & Hunter 2 Zone 55,000 BTU OLIVIA Ductless Mini Split AC Wall Mounted 24k+24k | No Kit No Kit










Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup currently unavailable at 3550 Northwest 113th Court
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Wall Mount
The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
INDOOR MODELS HYPER
| Indoor Model | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 2 Zone 55,000 BTU mini split cool?
The Cooper & Hunter 2 Zone mini split system can effectively cool two rooms, each with a capacity of 24,000 BTU. This makes it ideal for larger spaces or two separate areas in your home.
Can I mix BTU sizes with the Cooper & Hunter mini split system?
No, the Cooper & Hunter system is designed for two zones with specific BTU outputs of 24,000 each, totaling 55,000 BTU. Mixing BTU sizes may lead to inefficient operation and reduced performance.
Do all zones in the Cooper & Hunter dual-zone mini split run simultaneously?
Yes, in the Cooper & Hunter dual-zone system, both zones can run simultaneously, allowing for efficient temperature control in different areas. This is particularly beneficial for homes with varying heating or cooling needs.
Is it more efficient to use a Cooper & Hunter multi-zone mini split instead of multiple single-zone units?
Yes, the Cooper & Hunter 2 Zone mini split, with its 21.3 SEER rating, offers better energy efficiency compared to using multiple single-zone units. This efficiency translates to lower energy bills and a reduced environmental impact.
What warranty does the Cooper & Hunter Olivia offer?
The Cooper & Hunter Olivia mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This warranty ensures peace of mind for your investment.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split system comes pre-charged with R410A refrigerant for up to 25 ft of line set. This means you can install it without needing to add refrigerant, simplifying the setup process.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
3 Ton Mini Split Heating and Cooling Capacities Explained
System Sizing Masterclass 3 Ton Mini Split Heating and Cooling Capacities Explained Last week, I got called out to a...
Mini Splits FAQ , Top Questions Answered for US Homeowners
2026 Master Resource Mini Splits FAQ: Top Questions US Homeowners Ask in 2026 Get definitive answers to your ductless heat...
Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control
Architectural Integration Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control I still remember a brutal custom build...