Cooper&Hunter's Slim Duct Units offer a discreet and efficient climate control solution for residential and commercial spaces. With capacities ranging from 9,000 to 60,000 BTU and SEER2 ratings up to 20.2, these units ensure energy-efficient performance.
Their slim design allows for concealed installation in ceilings or walls, maintaining a sleek interior. Equipped with advanced inverter technology, quiet operation, and optional Wi-Fi control, Slim Duct Units provide reliable, customizable comfort while blending seamlessly into any space.
Perfect for single or multi-zone systems, they deliver powerful performance with minimal ductwork.
Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.
Main Features
Cooper&Hunter's Slim Duct Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.
Technical Specifications
INDOOR HYPER
Indoor Model
CH-MO9DTUI
CH-M12DTUI
CH-M18DTUI
CH-M24DTUI
CH-36LCDTU/I
CH-48LCDTU/I
CH-60LCDTU/I
Power Supply (V, Ph, Hz)
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
Cooling (Btu/h)
9,000
12,000
17,000
24,000
36,000
48,000
60,000
Heating (Btu/h)
10,000
12,500
19,000
25,000
42,000
52,000
57,000
Minimum Circuit Ampacity (MCA) (A)
1.2
1.3
3
3
3
5
5
Max. Fuse (A)
15
15
15
15
15
15
15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM)
353/353/282/176
353/353/282/176
529/529/450/371
775/775/693/435
1,082/1,082/912/703
1,529/1,529/1,118/735
2,303/2,156/1,709/1,262
Indoor Noise Level (Hi/Mi/Lo) (dB(A))
33/30.5/27
40/31.5/26.5
40/37.5/35
44/40/35.5
49.5/46.5/43
54.5/50.5/47.5
54/49.5/46
Dimension (W×D×H) (inch)
27.56×19.92×7.87
27.56×19.92×7.87
34.65×26.54×8.27
43.31×30.47×9.80
53.54×30.47×9.80
47.24×34.41×11.81
55.12×33.78×18.11
Packing (W×D×H) (inch)
33.86×21.26×11.22
33.86×21.26×11.22
42.13×28.54×11.02
51.38×31.69×12.40
61.81×31.69×12.99
55.31×36.02×14.37
63.19×35.83×21.06
Net/Gross Weight (lbs.)
39.02/48.28
39.24/48.50
55.34/67.02
90.39/105.82
110.89/128.09
119.71/141.76
174.60/200.40
Room Temperature Cooling (°F)
62~90
62~90
62~90
62~90
62~90
62~90
62~90
Room Temperature Heating (°F)
32~86
32~86
32~86
32~86
32~86
32~86
32~86
Liquid Side/Gas Side (inch)
1/4" / 3/8"
1/4" / 1/2"
1/4" / 1/2"
3/8" / 5/8"
3/8" / 5/8"
3/8" / 5/8"
3/8" / 7/8"
OUTDOOR HYPER
System Type
Hyper
Regular
Outdoor Model
CH-HPR09-230VO
CH-HPR12-230VO
CH-HPR18-230VO
CH-HPR24-230VO
CH-NHPR36LCU-230VO
CH-NHPR48LCU-230VO
CH-ES09-230VO
CH-ES12-230VO
CH-ES18-230VO
CH-ES24-230VO
CH-N36LCU-230VO
CH-N48LCU-230VO
Power Supply (V,Ph,Hz)
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
208/230,1,60
Voltage Range (V)
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
Cooling
Rated Capacity (range) (Btu/h)
2,850~11,100
3,000~13,700
5,600~17,000
5,600~17,000
12,400~36,000
2,700~48,900
2,970~10,500
2,800~14,100
5,600~16,000
8,100~26,200
12,400~36,000
16,600~48,000
Rated Current (A)
3.17
4.32
8
8.5
17.6
25.24
3.17
3.92
6.01
8.78
17.39
23.1
EER2 (Btu/h)
13
12.7
12.5
11
9.5
8.3
13
14
12.5
12.5
9.4
9.5
SEER2 (Btu/h)
20.5
22.3
20
20.5
19.4
16.8
20
22.7
20.5
21.5
19.2
18.5
Heating at 47°F
Rated Capacity (range) (Btu/h)
2,270~12,500
2,000~15,300
8,700~21,000
11,800~27,000
11,200~50,000
11,800~58,000
2,230~11,650
2,000~14,600
7,700~19,000
10,600~30,000
11,200~38,000
11,850~52,000
Rated Current (A)
4.58
4.99
10.8
9.8
17.1
21.92
4.16
4.78
8.21
10
15.55
21.5
COP (W/W)
3.09
3.26
2.95
3.5
3.05
3.17
3.08
3.37
2.78
3.32
3.18
3.1
HSPF4
10.3
10.2
10.5
9.7
10.5
10.7
10
10
10.5
9.7
8.8
9.8
HSPF5
7.8
8.8
7.8
9.2
8.5
8.5
8.2
7.8
8
7.8
7
7.5
Minimum Circuit Ampacity (A)
15
15
20
25
40
40
13
13
19
23
30
39
Max. Fuse (Outdoor Unit) (A)
15
15
25
35
50
50
15
15
30
30
45
50
Outdoor Air Flow (Max.) (CFM)
1,324
1,324
1,765
2,235
4,500
4,500
1,294
1,294
2,059
2,235
3,000
4,500
Outdoor Noise Level (Sound Pressure) (dB(A))
55
53
59
62
64
67
53
54
60.5
61
63.5
65
Dimension (WxDxH) (inch)
31.69x12.99x21.81
31.69x12.99x21.81
35.04x13.46x26.50
37.24x16.14x31.89
37.48x16.34x52.48
37.48x16.34x52.48
30.12x11.93x21.85
30.12x11.93x21.85
35.04x13.46x26.50
37.24x16.14x31.89
37.24x16.14x31.89
37.48x16.34x52.48
Packing (WxDxH) (inch)
36.02x14.57x24.21
36.02x14.57x24.21
39.17x15.67x29.13
42.91x19.69x34.84
43.11x19.49x58.27
43.11x19.49x58.27
34.92x13.27x24.02
34.92x13.27x24.02
39.17x15.67x29.13
42.91x19.69x34.84
42.91x19.69x34.84
43.11x19.49x58.27
Net/Gross Weight (lbs.)
74.07/80.25
73.63/79.37
100.97/108.03
134.48/144.40
220.24/248.02
227.07/255.73
63.71/69.00
63.71/69.00
94.36/100.97
124.78/134.92
155.42/166.23
219.14/249.12
Refrigerant Type/Charge (oz.)
R410A/41.62
R410A/41.62
R410A/65.26
R410A/91.71
R410A/148.4
R410A/148
R410A/38
R410A/38
R410A/56.44
R410A/82.89
R410A/112.9
R410A/158.7
Refrigerant Precharge Length (ft.)
25
25
25
25
25
25
25
25
25
25
25
25
Additional Charge for Each ft. (oz/ft)
0.16
0.16
0.16
0.32
0.32
0.32
0.16
0.16
0.16
0.32
0.32
0.32
Design Pressure (PSIG)
550/340
550/340
550/340
550/340
550/340
550/340
550/340
550/340
550/340
550/340
550/340
550/340
Refrigerant Piping Liquid Side/Gas Side (inch)
1/4"/3/8"
1/4"/1/2"
1/4"/1/2"
3/8"/5/8"
3/8"/5/8"
3/8"/5/8"
1/4"/3/8"
1/4"/1/2"
1/4"/1/2"
3/8"/5/8"
3/8"/5/8"
3/8"/5/8"
Max. Pipe Length (ft.)
82.02
82.02
98.42
164.04
213.25
213.25
82.02
82.02
98.42
164.04
213.25
213.25
Max. Difference in Level (ft.)
32.81
32.81
65.62
82.02
98.42
98.42
32.81
32.81
65.62
82.02
98.42
98.42
Ambient Temperature
Cooling (°F)
-22~122
-22~122
-22~122
-22~122
5~122
5~122
-13~122
-13~122
-13~122
-13~122
5~122
5~122
Heating (°F)
-22~75
-22~75
-22~75
-22~75
-22~75
-22~75
-13~75
-13~75
-13~75
-13~75
5~75
5~75
Multiple Control
Methods
Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.