| SEER | |
|---|---|
| Compressor | |
| Brand | |
| Voltage | |
| WiFi | |
| Type | |
| Freon |
⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:
- Same Brand Only: Only pair with other same Brand and Series.
- Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).
Mixing different brands or refrigerant types will cause the system to fail and void your warranty.
Availability
Out of stock right now
For the next arrival, call (855) 775-4822.
— we’ll fill in your ZIP. Used only for delivery dates and pickup.
FREE shipping to We don’t ship to .Pick up at Medley, FL ·
9400 Northwest 104th Street, Suite 150, Medley, FL 33178
Buy with Shop skips your pickup choice; Add to cart keeps it.
Delivery dates are estimates
Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated
Questions about this system?
Answers in seconds — tap a question below
-
Up to about 1,100 sq ft at average conditions. We size at about 22 BTU per sq ft, more conservative than the ENERGY STAR room-size chart. Add capacity for a hot climate, ceilings over 8 ft, strong sun (+10%), a kitchen (+4,000 BTU) or each person over two (+600 BTU). For a room-by-room load calculation, ask your installer for an ACCA Manual J. Not sure? Call (855) 775-4822 and we'll confirm the right size for your space.
-
12,000 BTU = 1 ton — "tons" is just the older way of stating capacity. So 24,000 BTU = 2 tons, 36,000 = 3 tons, and so on. This system is 24,000 BTU (2-ton). BTU tells you the capacity; SEER2 tells you the efficiency.
-
It uses R454B — the newest low-GWP eco refrigerant, so it's future-proof and efficient. The outdoor unit ships pre-charged for a standard line set, so most installs need no extra refrigerant; your licensed, EPA-608-certified installer verifies the charge and tops it off if your line set is longer.
-
Rated SEER2 19.7 — a strong efficiency number, and the higher it is the lower your energy bills. Its inverter compressor ramps up and down instead of cycling on/off, so it holds the temperature steadily, runs quietly, and uses less power than a standard AC or window unit.
-
Needs a dedicated 230V circuit, like a large household appliance, so it can deliver full capacity to larger rooms and multi-zone setups. Your licensed HVAC installer or electrician sets up the correct breaker and disconnect to meet local electrical code.
-
Yes — a big upgrade. It's far more efficient (inverter, SEER2 19.7) and much quieter, since the compressor sits outside instead of in your window or on the floor. It mounts permanently, doesn't block a window, and heats as well as cools year-round. Higher upfront cost, but lower bills and a longer lifespan.
-
Yes to all three. It's an inverter heat pump — cools in summer, heats in winter (even in the cold), far more efficiently than electric heaters. A Dry mode also pulls out humidity, so rooms feel cooler and less muggy.
-
Yes — WiFi is not included, so you can set schedules, change the temperature, and even turn it on before you get home, all from the mobile app (and pair it with voice assistants). A standard remote is included too.
-
Ships as a complete set: CH-RS24MAHU. Everything arrives together — check the photos and specs for the full kit.
-
It should be installed by a licensed, EPA-608-certified HVAC professional — we don't recommend DIY installation. Handling refrigerant requires EPA Section 608 certification under U.S. law, and professional installation keeps the system safe, code-compliant, and your manufacturer warranty valid.
-
Yes — you get full inverter heat-pump technology and the same core features as premium brands without paying for the name, which is how we keep prices low. Shipping is free on items over $300 within the U.S., and our team can help with sizing and support.
Why buy this mini split from MiniSplitsForLess
- Free Shipping on items over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Multi-Position Air Handler
Installs in upflow, downflow or horizontal orientation to fit a closet, attic or utility room, delivering ducted 24000 BTU comfort to the whole home.
Inverter Efficiency — SEER2 19.7
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 19.7 on 230V — steady comfort with noticeably lower energy bills.
Right-Sized Coverage
Heats & cools up to about 1,100 sq ft at average conditions (about 22 BTU per sq ft).
Multi-Position Air Handler
Engineered for flexibility and designed for performance, the Cooper&Hunter Multi-Position Air Handler delivers reliable comfort in a wide range of residential and light commercial applications. Whether installed in upflow, downflow, or horizontal configurations, this unit adapts seamlessly to your space while maintaining optimal efficiency and quiet operation.
Built with Cooper&Hunter’s commitment to innovation, the Multi-Position Air Handler offers advanced airflow management, durable construction, and compatibility with high-efficiency heat pump systems.
Its sleek, compact design allows for easy installation, while the smart control options ensure user-friendly operation and precision climate control.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
The Cooper&Hunter Multi-Position Air Handler offers flexible installation in upflow, downflow, or horizontal configurations. Designed for quiet, efficient performance, it features a high-performance blower, durable insulated cabinet, and smart control compatibility—making it an ideal solution for reliable, customizable comfort in residential or light commercial settings.
Technical Specifications
Indoor Unit Specs
| Model | CH-RS24MAHU |
|---|---|
| Unit Dimensions (WxDxH) | 17.52 x21.02 x 45 in |
| Net/Gross Weight | 104.28/125.88 lb |
| Packing Dimensions (WxDxH) | 20.87 x 26.57 x 48.62 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 4 A |
| Copper Line Size (Liquid/Gas) | 3/8"/5/8" |
| Noise Level (Hi/Med/Lo) | 43.5/40/25.5 dB |
| Dehumidification | 4.8 pt/h |
| Drain Pipe Diameter | 3/4" |
| Controller | wire controller + remote controller available |
System Specs
| Cooling Capacity | 24,000 BTU |
|---|---|
| SEER2 | 19.7 |
| Voltage | 230V |
| Refrigerant Type | R454B |
| Compressor | Inverter |
| WiFi | Not Included |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
| Indoor Model | CH-RS18MAHU | CH-RS24MAHU | CH-RS36LCAHU | CH-RS48LCAHU | CH-RS60LCAHU |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Cooling | |||||
| Rated Capacity (Btu/h) | 18,000 | 23,000 | 36,000 | 48,000 | 54,000 |
| Rated Current (A) | 9.1 | 8.7 | 13.4 | 22 | 24 |
| Heating | |||||
| Rated Capacity (Btu/h) | 19,500 | 26,000 | 38,000 | 50,000 | 59,000 |
| Rated Current (A) | 9.5 | 9.7 | 14.3 | 19 | 21.8 |
| Minimum Circuit Ampacity (MCA) (A) | 3.5 | 4 | 5 | 7.5 | 9 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) (CFM) | 618.0/576.8/529.7/488.5/ N/A | 824.0/759.3/694.5/629.8/- | 1189/1083/971.2/865.2/ N/A | 1601/1471.5/1283.1/1094.8// | 1807/1553.9/1353.8/724/ N/A |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) (dB(A)) | N/A/42.5/37.5/30.0/N/A | N/A/43.5/40/25.5/N/A | N/A/47/42/30.5/N/A | 56.5/54.5/51/48// | N/A/53.0/48.0/33.5/N/A |
| ESP (Range) | 0-0.8 | 0-0.8 | 0-0.8 | 0-0.8 | 0-0.8 |
| Indoor | |||||
| Dimension (WxDxH) (inch) | 17.52x21.02x45.00 | 17.52x21.02x45.00 | 21.02x21.02x49.02 | 24.49x21.02x52.99 | 24.49x21.02x52.99 |
| Packing (WxDxH) (inch) | 20.87x26.57x48.62 | 20.87x26.57x48.62 | 24.41x26.57x52.56 | 27.95x26.77x56.50 | 27.95x26.77x56.50 |
| Net/Gross Weight (lbs.) | 104.72/125.66 | 104.28/125.88 | 127.87/152.78 | 161.82/191.58 | 161.82/191.58 |
| Room Temperature | |||||
| Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas side (inch) | 1/4” / 1/2” | 3/8” / 5/8” | 3/8” / 3/4” | 3/8” / 3/4” | 3/8” / 3/4” |
Outdoor HYPER
| Outdoor Model | CH-RHP18-230VO | CH-RHP24-230VO | CH-RHP36LCU-230VO | CH-RHP48LCU-230VO | CH-RHP60LCU-230VO |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated (V, Ph, Hz) | 208-230, 1, 60 | 208-230, 1, 60 | 208-230, 1, 60 | 208-230, 1, 60 | 208-230, 1, 60 |
| Voltage range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Current (A) | 8.7 | 13.4 | 13.4 | 22 | 24 |
| Cooling | |||||
| Rated Capacity Range (Btu/h) | 6,000–20,400 | 7,500–27,000 | 5,700–36,400 | 7,300–55,000 | 13,700–58,000 |
| EER2 (Btu/w) | 12 | 12 | 11.7 | 10.7 | 10.2 |
| SEER2 (Btu/w) | 18.7 | 18.7 | 17.2 | 15.2 | 15.2 |
| Rated Capacity Range (Btu/h) | 5,000–21,600 | 8,800–29,000 | 9,500–44,000 | 9,500–65,000 | 10,000–66,100 |
| COP (W/W) | 3.64 | 3.55 | 3.39 | 3.06 | 3.36 |
| HSPF4 (Btu/w) | 13.5 | 13.2 | 12.1 | 10.7 | 10.7 |
| HSPF5 (Btu/w) | 10.8 | 10.7 | 9.7 | 8.7 | 8.7 |
| Heating at 5°F (-15°C) Rated Capacity (Btu/h) | 18,000 | 23,600 | 38,000 | 46,000 | 53,000 |
| Minimum Circuit Ampacity (MCA) (A) | 19 | 24.9 | 38 | 44 | 44 |
| Max. Fuse (A) | 25 | 40 | 45 | 45 | 45 |
| Outdoor Air Flow (Max.) (CFM) | 1,765.8 | 2,236.7 | 3,001.9 | 4,237.9 | 4,237.9 |
| Outdoor Noise Level (dB(A)) | 59 | 61.5 | 65.5 | 65 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 39.17x15.67x29.13 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x57.48 | 43.11x19.49x57.48 |
| Net/Gross Weight (lbs.) | 99.87/107.80 | 130.29/141.31 | 206.57/237.44 | 208.78/239.86 | 230.28/261.69 |
| Refrigerant Type/Quantity (oz.) | R454B/55.38 | R454B/63.49 | R454B/126.99 | R454B/126.99 | R454B/151.68 |
| Refrigerant Precharge (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for each ft. (oz./ft.) | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant piping Liquid side/Gas side (inch) | 1/4” / 1/2” | 3/8” / 5/8” | 3/8” / 3/4” | 3/8” / 3/4” | 3/8” / 3/4” |
| Max. Pipe Length (ft.) | 98.4 | 164 | 246 | 246 | 246 |
| Max. Difference in Level (ft.) | 65.6 | 82 | 98.4 | 98.4 | 98.4 |
| Ambient Temperature Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| AHRI | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| ETL | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Energy Star | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| NEEP | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Indoor REGULAR
| Indoor Model | CH-RS18MAHU | CH-RS24MAHU | CH-RS30MAHU | CH-RS36LCAHU | CH-RS48LCAHU | CH-RS60LCAHU |
|---|---|---|---|---|---|---|
| Power Supply | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Cooling Capacity (Btu/h) | 18,000 | 24,000 | 30,000 | 36,000 | 48,000 | 60,000 |
| Cooling Current (A) | 6.7 | 9.3 | 12.5 | 17.4 | 21.5 | 25.5 |
| Heating Capacity (Btu/h) | 18,000 | 25,000 | 30,000 | 38,000 | 50,000 | 59,000 |
| Heating Current (A) | 6.7 | 9.2 | 11.2 | 14.4 | 22 | 24 |
| MCA (A) | 3.5 | 4 | 6 | 6 | 9.8 | 11 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 618.0/576.8/529.7/488.5/ N/A | 824.0/759.3/694.5/629.8/ N/A | 988.8/894.7/806.4/712.2/ N/A | 1189/1083/971.2/865.2/ N/A | 1601.0/1471.5/1283.1/1094.8/ N/A | 1807.0/1553.9/1353.8/724.0/ N/A |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | N/A/42/39.5/33/N/A | N/A/43.5/41.5/28.5/N/A | N/A/44/41/26/N/A | N/A/47/42/31/N/A | 56.5/54/51/48/N/A | N/A/51/48/42.5/N/A |
| ESP (Range) | 0-0.8 | 0-0.8 | 0-0.8 | 0-0.8 | 0-0.8 | 0-0.8 |
| Dimension (WxDxH) (inch) | 21.02x17.52x45.00 | 21.02x17.52x45.00 | 21.02x21.02x49.02 | 21.02x21.02x49.02 | 21.02x24.49x52.99 | 21.02x24.49x52.99 |
| Packing (WxDxH) (inch) | 26.57x20.87x48.62 | 26.57x20.87x48.62 | 26.57x24.41x52.56 | 26.57x24.41x52.56 | 27.95x26.77x56.50 | 27.95x26.77x56.50 |
| Net/Gross Weight (lbs.) | 104.72/125.66 | 104.28/125.88 | 127.43/151.68 | 127.87/152.78 | 161.82/191.58 | 164.02/189.82 |
| Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side (inch) | 1/4“ / 1/2” | 3/8“ / 5/8“ | 3/8“ / 5/8“ | 3/8“ / 3/4“ | 3/8“ / 3/4“ | 3/8“ / 3/4“ |
Outdoor REGULAR
| Outdoor Model | CH-RES18-230VO | CH-RES24-230VO | CH-REL30-230VO | CH-R36LCU-230VO | CH-R48LCU-230VO | CH-R60LCU-230VO |
|---|---|---|---|---|---|---|
| Power Supply | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Current (A) | 6.7 | 9.3 | 12.5 | 17.4 | 21.5 | 25.5 |
| Cooling Capacity Range (Btu/h) | 5,600–20,400 | 6,700–29,600 | 9,200–34,000 | 8,900–38,200 | 9,500–52,000 | 21,800–57,300 |
| EER2 | 11.7 | 12.1 | 12 | 11.7 | 10.7 | 10.2 |
| SEER2 | 18.5 | 19.7 | 17 | 15.8 | 15.2 | 15.2 |
| Heating Capacity Range (Btu/h) | 5,500–21,800 | 5,800–33,800 | 8,500–33,000 | 6,400–43,000 | 11,700–60,000 | 11,800–60,300 |
| COP | 3.60 | 3.53 | 3.60 | 3.36 | 3.36 | 3.34 |
| HSPF4 | 9.8 | 9.7 | 8.7 | 9.3 | 9.0 | 9.1 |
| HSPF5 | 7.7 | 7.3 | 7.7 | 7.3 | 7.2 | 7.1 |
| Heating at 5°F (-15°C) (Btu/h) | 13,000 | 18,000 | 20,400 | 24,200 | 35,200 | 35,400 |
| MCA (A) | 18 | 24 | 28 | 33 | 39 | 42 |
| Max. Fuse (A) | 20 | 25 | 30 | 35 | 40 | 45 |
| Outdoor Air Flow (CFM) | 1,765.8 | 2,236.7 | 2,236.7 | 2,413.3 | 4,237.9 | 4,237.9 |
| Outdoor Noise Level (dB(A)) | 56.5 | 58.5 | 61 | 62.5 | 65 | 62.5 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 39.17x15.67x29.13 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x57.48 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs.) | 92.59/100.31 | 122.13/132.28 | 142.86/154.54 | 152.34/162.48 | 208.78/239.86 | 209.44/240.08 |
| Refrigerant Type/Quantity (oz.) | R454B/47.97 | R454B/70.55 | R454B/84.66 | R454B/91.71 | R454B/126.99 | R454B/144.62 |
| Refrigerant Precharge (ft.) | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for each ft. (oz./ft.) | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant piping Liquid side/Gas side (inch) | 1/4” / 1/2” | 3/8” / 5/8” | 3/8” / 5/8” | 3/8” / 3/4” | 3/8” / 3/4” | 3/8” / 3/4” |
| Max. Pipe Length (ft.) | 98.4 | 164 | 164 | 246 | 246 | 213.2 |
| Max. Difference in Level (ft.) | 65.6 | 82 | 82 | 98.4 | 98.4 | 98.4 |
| Ambient Temp Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -22~122 | -13~122 |
| Ambient Temp Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -22~75 | -13~75 |
| AHRI | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| ETL | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Energy Star | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| NEEP | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
Shipping & Returns
- Free shipping on every item over $300.
- Delivery estimate for your ZIP is shown in the buy box above.
- Returns accepted per our policy — unopened units in original packaging.
Warranty
7-year compressor / 5-year parts
- Limited manufacturer warranty on the compressor and sealed system components.
- Your order number is the proof of purchase — keep it for any claim.
Multiple Control Methods
Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my home?
For a coverage area of up to 1,200 sq ft, the Cooper & Hunter 24,000 BTU indoor air handler is an excellent choice. This unit is designed to effectively cool or heat medium to large spaces, ensuring optimal comfort.
Can I install a mini split myself, or do I need a professional?
While some homeowners may attempt a DIY installation, it's recommended to hire a professional for best results, especially with the Cooper & Hunter 24,000 BTU unit. Professional installation ensures proper setup and compliance with local codes, maximizing efficiency.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter 24,000 BTU mini split is pre-charged with R454B refrigerant for line sets up to 25 ft. This feature simplifies installation, as you won't need to worry about adding refrigerant during setup.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter 24,000 BTU indoor air handler operates on a 230V electrical system. It's essential to ensure your home's electrical setup is compatible with this voltage for optimal performance.
What warranty does Cooper & Hunter offer on their mini split system?
The Cooper & Hunter 24,000 BTU unit comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register within 30 days of purchase. This warranty offers peace of mind for your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter 24,000 BTU mini split boasts an impressive SEER rating of 19.7, making it highly efficient for both cooling and heating. This rating not only helps lower energy bills but also contributes to environmental sustainability.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
What is a mini-split?
Ductless HVAC Basics What Is a Mini Split? Parts, How It Works & 2026 Costs Pre-Purchase Guide 2026 Edition HVAC...
Whole House Mini-Split & Heat Pump Systems
2026 Cost & Sizing Guide Whole House Mini Split Systems: 2026 Costs, Zone Counts & Sizing Multi-Zone Olivia & Olivia...
Cooper & Hunter Mini Split: 2026 Prices & Real Reliability Tests
2026 Buyer's Guide Cooper and Hunter Mini Split Guide 2026: Prices, Series & Specs MIA Olivia Hyper Heat 2026 Pricing...