Cooper & Hunter 6 Zone 60,000 BTU Concealed Duct Mini Split AC R454B 6K+6K+6K+12K+12K+12K | No Kit

Cooper & Hunter

CH-R60MES-230VORH06MDTRH06MDTRH06MDTRH12MDTRH12MDTRH12MDT-NO
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 22
WiFi Included
Zone Six Zone
Type Multi-Zone
Freon R454B
Compressor Inverter
$8,460.00
Shipping Policy calculated at checkout.
Title: No Installation

Pickup available at 3550 Northwest 113th Court

Usually ready in 2-4 days

FREE Armbridge Accessory With This Purchase

Choose one below — it will be added to your cart for free

Select your free accessory:

FREE
ARMBRIDGE AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base with Built-In Leveler
AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Zinc,...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Foldable 304 Stainless Steel, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Folda...
FREE
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity
Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets ...
FREE
ARMBRIDGE 18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, Anti-Slip Foundation for HVAC Systems and Outdoor Equipment
18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, ...
Free gift added to your cart!
Title
Discount Banner
TrustScore 4.8

Concealed Duct

Cooper&Hunter's Slim Duct Units offer a discreet and efficient climate control solution for residential and commercial spaces. With capacities ranging from 9,000 to 60,000 BTU and SEER2 ratings up to 20.2, these units ensure energy-efficient performance.

Their slim design allows for concealed installation in ceilings or walls, maintaining a sleek interior. Equipped with advanced inverter technology, quiet operation, and optional Wi-Fi control, Slim Duct Units provide reliable, customizable comfort while blending seamlessly into any space.

Perfect for single or multi-zone systems, they deliver powerful performance with minimal ductwork.

Slim duct air vent system with purple shield logo and black body.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms
White air conditioning unit with black fan and copper tubing design.

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Modern white and gray ductless mini-split air conditioner with sleek design, suitable for small to medium-sized rooms.

Main Features

Cooper&Hunter's Slim Duct Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.

An outdoor air conditioning unit designed for high performance in extreme hot and cold weather.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

Indoor

Indoor Model CH-RS06MDT-MS
CH-RS06-12MDT-MS (Dip Switch 6)
CH-RS09MDT-MS
CH-RS06-12MDT-MS (Dip Switch 9)
CH-RS12MDT-MS
CH-RS06-12MDT-MS (Dip Switch 12)
CH-RS18MDT-MS CH-RS24MDT-HS CH-RS36CLCDT-HS CH-RS48CLCDT-HS CH-RS60CLCDT-HS
Power Supply 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Rated Capacity 6,500/8,000 9,000/10,000 12,000/12,500 17,000/19,000 24,000/26,000 36,000/42,000 48,000/52,000 55,000/60,000
Minimum Circuit Ampacity (MCA) 3 3 3 3 3 4 5 5
Max. Fuse 15 15 15 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM 323.7/264.9/206.0/147.2/117.7 323.7/264.9/206.0/147.2/117.7 400.2/323.7/264.9/176.6/117.7 600.4/559.2/500.3/441.4/NA 853.5/706.3/618.0/500.3/NA 1236.1/1059.5/941.8/766.5/NA 1648.1/1471.5/1294.9/1059.5/NA 2001.2/1706.9/1412.6/1118.3/NA
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) NA/32.5/30.5/29.5/22 NA/32.5/31/29.5/23 NA/36/34.5/32.5/25.5 NA/40/39/38/32 NA/40/37/35/29.5 NA/45/40/34/31 NA/51/46/42/40 NA/52/48/42/41
Dimension (WxDxH) inch 27.56 x 19.92 x 7.87 27.56 x 19.92 x 7.87 27.56 x 19.92 x 7.87 34.65 x 26.54 x 8.27 39.37 x 29.53 x 9.65 47.24 x 29.53 x 11.81 47.24 x 29.53 x 11.81 55.12 x 31.50 x 14.96
Packing (WxDxH) inch 33.86 x 21.26 x 11.22 33.86 x 21.26 x 11.22 33.86 x 21.26 x 11.22 42.13 x 28.54 x 11.02 48.23 x 33.86 x 11.97 56.10 x 33.86 x 14.13 56.10 x 33.86 x 14.13 62.99 x 36.02 x 17.52
Net/Gross Weight lbs. 39.46/46.74 39.46/46.74 39.46/46.74 54.45/66.14 80.47/91.93 106.26/120.37 111.33/124.78 161.38/178.13
Room Temperature Cooling °F 60~90 60~90 60~90 60~90 60~90 60~90 60~90 60~90
Room Temperature Heating °F 32~86 32~86 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side inch 1/4"/3/8" 1/4"/3/8" 1/4"/3/8" 1/4"/1/2" 3/8"/5/8" 3/8"/3/4" 3/8"/3/4" 3/8"/3/4"

Outdoor Regular

Specification CH-R18MES-230VO CH-R28MES-230VO CH-R36MES-230VO CH-R48MES-230VO CH-R60MES-230VO
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (range) (Btu/h) 5,400~21,600 7,200~32,000 9,000~42,000 12,000~55,000 19,000~62,000
Cooling Rated Current (A) 6 9.2 13.5 16.6 26.2
EER2 14 13 12 12.5 10
SEER2 25.1 25 24 24 22
Heating Rated Capacity (range) (Btu/h) 5,700~21,600 8,400~29,000 10,000~42,500 13,000~53,000 20,000~60,000
Heating Rated Current (A) 6.8 9.2 14 16.3 21
Heating at 47°F COP (W/W) 3.8 3.8 3.5 3.8 3.7
HSPF4 9.8 9.5 9.5 10.3 9.5
HSPF5 7.8 7 7 8 7.4
Heating at 5°F Rated Capacity (Btu/h) 13,500 19,000 26,000 36,000 39,000
Minimum Circuit Ampacity (Outdoor unit) (A) 16 23 30.5 40 40
Max. Fuse (Outdoor unit) (A) 20 25 35 45 45
Outdoor Air Flow (Max) (CFM) 1,765.8 2,130.7 2,148.4 4,502.8 4,502.8
Outdoor Noise Level (Sound Pressure) (dB(A)) 59.5 61 64.5 63 65
Dimension (W×D×H) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (W×D×H) (inch) 40.55x17.24x29.53 42.91x19.68x34.84 42.91x19.68x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs) 100.53/109.35 138.89/149.69 168.87/180.12 222.00/254.19 237.88/270.28
Refrigerant Type/Charged (oz) R454B/61.73 R454B/84.66 R454B/120.63 R454B/148.15 R454B/151.68
Refrigerant Precharge (ft) 75 100 125 150 150
Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Refrigerant Piping Gas Side (inch) 3 x 3/8" 3 x 3/8" + 1 x 1/2" 4 x 3/8" + 1 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max. Pipe Length (ft) 196.8 262.4 262.4 262.4 262.4
Max. Length for One Indoor Unit (ft) 98.4 114.8 114.8 114.8 114.8
Max. Height Difference in Level (ft) 49.2 49.2 49.2 49.2 49.2
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) -13~122 -13~122 -13~122 -13~122 -13~122
Ambient Temperature Heating (°F) -13~75 -13~75 -13~75 -13~75 -13~75
Certification: AHRI
Certification: Energy Star
Certification: NEEP
Certification: ETL

Outdoor Hyper

Specification CH-RVHP19M-230VO CH-RVHP28M-230VO CH-RVHP36M-230VO CH-RVHP48M-230VO CH-RVHP55M-230VO
Power Supply (V/Ph/Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Operating Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Capacity (BTU/h) 5,400~28,000 7,200~37,000 9,000~43,000 12,000~57,000 19,000~59,000
SEER2 5.6 9.5 12 17.3 18.5
EER 15 12.5 13 12 12
IEER 25 23 23 23 22.2
Heating Capacity (BTU/h) 5,700~27,000 8,400~36,000 10,000~44,000 13,000~57,000 20,000~59,000
HSPF2 6.5 9.1 11.5 17.3 20.1
COP 4 3.8 4 3.7 3.5
SCOP 10.4 10.5 10.7 11 10.5
Power Input (W) 8.5 8.5 8.5 9 8.5
Air Flow (CFM) 19,000 27,000 36,000 47,000 47,000
Sound Level Indoor (dBA) 17.5 30 37 37 39.5
Sound Level Outdoor (dBA) 20 35 40 40 40
Weight Indoor (lbs) 2,130.7 2,148.4 3,037.2 4,502.8 4,502.8
Weight Outdoor (lbs) 61.5 61 65 65 65
Dimensions Indoor (in) 37.24x16.14x31.89 37.24x16.14x31.89 38.58x16.34x38.39 37.48x16.34x52.48 37.48x16.34x52.48
Dimensions Outdoor (in) 42.91x19.68x34.84 42.91x19.68x34.84 45.08x19.68x42.52 43.11x19.49x58.27 43.11x19.49x58.27
Shipping Weight Indoor/Outdoor (lbs) 137.35/148.15 168.43/179.67 211.86/244.71 246.47/276.68 246.47/276.68
Refrigerant Type/Amount (lbs) R454B/78.31 R454B/120.63 R454B/134.04 R454B/151.68 R454B/151.68
Fuse Size (A) 75 100 125 150 150
Wire Size (AWG) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Control Voltage (V) 550/340 550/340 550/340 550/340 550/340
Liquid Line 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Suction Line 3 x 3/8" 3 x 3/8" + 1 x 1/2" 3 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max Line Length (ft) 196.8 262.4 262.4 262.4 262.4
Max Elevation Diff (ft) 98.4 114.8 114.8 114.8 114.8
Max Head Pressure (ft) 49.2 49.2 49.2 49.2 49.2
Max Suction Pressure (ft) 33 33 33 33 33
Operating Range Cooling (°F) -22~122 -22~122 -22~122 -22~122 -22~122
Operating Range Heating (°F) -22~75 -22~75 -22~75 -22~75 -22~75
Feature 1
Feature 2
Feature 3
Feature 4

Multiple Control Methods

Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

How many rooms can the Cooper & Hunter 6 Zone 60,000 BTU mini split cool?

The Cooper & Hunter 6 Zone 60,000 BTU mini split can effectively cool up to six separate rooms, making it ideal for larger homes or multi-room setups. With a coverage area of up to 2500 sq ft, it offers versatile climate control for various spaces.

Can I mix BTU sizes with the Cooper & Hunter mini split system?

Yes, you can mix BTU sizes with the Cooper & Hunter mini split system as long as the total does not exceed the 60,000 BTU capacity. This flexibility allows you to customize the cooling and heating for different rooms based on their specific needs.

Do all zones run simultaneously in the Cooper & Hunter multi-zone system?

No, not all zones in the Cooper & Hunter multi-zone system run simultaneously; you can control each zone independently. This feature enables energy savings by allowing you to cool or heat only the occupied areas, enhancing overall efficiency.

What is the warranty on the Cooper & Hunter mini split system?

The Cooper & Hunter mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of purchase. This warranty ensures that your investment is protected for several years.

Does the Cooper & Hunter mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter mini split is pre-charged with R454B refrigerant for installation with up to 25 ft of line set. This feature simplifies installation, allowing for quick setup and immediate use after installation.

What makes the SEER rating of 22.0 efficient for the Cooper & Hunter mini split?

The Cooper & Hunter mini split's SEER rating of 22.0 indicates exceptional energy efficiency, significantly outperforming many standard units. This high efficiency not only reduces energy costs but also provides better performance compared to multiple single-zone units.