Cooper & Hunter Hyper Heat 12,000 BTU Indoor Ceiling Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump

Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Type | |
| Freon | |
| Compressor |
⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:
- Same Brand Only: Only pair with other same Brand and Series.
- Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).
Mixing different brands or refrigerant types will cause the system to fail and void your warranty.
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Ceiling Cassette
Cooper&Hunter's Ceiling Cassette Units are designed to deliver superior comfort and efficiency while seamlessly integrating into ceiling spaces. Ideal for both residential and commercial settings, these units offer advanced airflow distribution and quiet operation for maximum convenience.
Engineered with energy-saving technology, durable anti-corrosion coatings, and a sleek, compact design, they ensure reliable performance and blend effortlessly with modern interiors.
Experience enhanced climate control with Cooper&Hunter's Ceiling Cassette Units—a perfect blend of innovation, durability, and elegance.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Ceiling Cassette Units deliver efficient climate control with advanced airflow distribution, energy-saving technology, and whisper-quiet operation. Designed for seamless ceiling integration, these units feature anti-corrosion coatings for durability and a sleek, compact design. Perfect for residential or commercial spaces, they combine performance, reliability, and modern aesthetics effortlessly.

Technical Specifications
| System Type |
Hyper
|
Regular
|
|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ceiling Cassette PRO | CH-RSH09-12MCT (Dip Switch for 9K) |
CH-RSH09-12MCT (Dip Switch for 12K) |
CH-RSH18MCT | CH-RSH24MCT | CH-RSH36LCCT | CH-RSH48LCCT | CH-RSH09-12MCT (Dip Switch 9) |
CH-RSH09-12MCT (Dip Switch 12) |
CH-RSH18MCT | CH-RSH24MCT | CH-RSH36LCCT | CH-RSH48LCCT | |
| Ceiling Cassette | CH-RH09MCT | CH-RH12MCT | CH-RH18MCT | CH-RH24MCT | CH-RH36LCCT | CH-RH48LCCT | CH-RH09MCT | CH-RH12MCT | CH-RH18MCT | CH-RH24MCT | CH-RH36LCCT | CH-RH48LCCT | |
| Panel Model Number | CH-NPNL09-18CT | CH-NPNL09-18CT | CH-NPNL09-18CT | CH-NPNL24-48CT | CH-NPNL24-48CT | CH-NPNL24-48CT | CH-NPNL09-18CT | CH-NPNL09-18CT | CH-NPNL09-18CT | CH-NPNL24-48CT | CH-NPNL24-48CT | CH-NPNL24-48CT | |
| Power Supply (V,Ph,Hz) | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | |
| Rated Capacity (Btu/h) | 9,000 | 12,000 | 16,000 | 23,400 | 36,600 | 48,000 | 9,000 | 12,000 | 16,800 | 24,000 | 36,000 | 48,000 | |
| Minimum Circuit Ampacity (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | |
| Indoor Air Flow - Turbo/Hi/Mi/Lo (CFM) | 417.9/364.9/306.1/194.2/147.2 | 417.9/364.9/306.1/194.2/147.2 | 447.3/388.5/317.8/194.2/147.2 | 765.2/706.3/635.7/547.4/N/A | 1041.8/947.6/853.5/753.4/659.2 | 1236.1/1124.2/1018.3/800.5/688.7 | 417.9/364.9/306.1/194.2/147.2 | 417.9/364.9/306.1/194.2/147.2 | 447.3/388.5/317.8/194.2/147.2 | 765.2/706.3/635.7/547.4/N/A | 1041.8/947.6/853.5/753.4/659.2 | 1236.1/1124.2/1018.3/800.5/688.7 | |
| Indoor Noise Level - Hi/Mi/Lo (dB(A)) | 42.5/40/37.5/26/24 | 46/43.5/40.5/27.5/26 | 48/44.5/41/27.5/23.5 | 48.5/45/42.5/33.5/N/A | 54/52.5/47/39.5/36.5 | 56/52.5/50/42.5/38.5 | 42.5/40/37.0/26.0/24.0 | 46/42.0/38.5/26.5/24.0 | 48/44.0/41.0/28.5/24.5 | N/A/45.5/43.0/33.5/30.5 | N/A/52.0/47.5/40.0/38.00 | N/A/52.0/49.5/41.5/38.00 | |
| Dimension (WxDxH) (inch) | 22.44x22.44x9.65 | 22.44x22.44x9.65 | 22.44x22.44x9.65 | 32.68x32.68x8.07 | 32.68x32.68x9.65 | 32.68x32.68x11.30 | 22.44x22.44x9.65 | 22.44x22.44x9.65 | 22.44x22.44x9.65 | 32.68x32.68x8.07 | 32.68x32.68x9.65 | 32.68x32.68x11.30 | |
| Packing (WxDxH) (inch) | 28.15x25.20x11.61 | 28.15x25.20x11.61 | 28.15x25.20x11.61 | 35.83x35.83x9.84 | 35.83x35.83x11.42 | 35.83x35.83x12.99 | 28.15x25.20x11.61 | 28.15x25.20x11.61 | 28.15x25.20x11.61 | 35.83x35.83x9.84 | 35.83x35.83x11.42 | 35.83x35.83x12.99 | |
| Net/Gross Weight (lbs.) | 35.27/41.89 | 35.27/41.89 | 35.27/41.89 | 47.18/59.08 | 59.30/71.43 | 64.59/76.06 | 35.27/41.89 | 35.27/41.89 | 35.27/41.89 | 47.18/59.08 | 59.30/71.43 | 64.59/76.06 | |
| Room Temperature | |||||||||||||
| Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 62~90 | 62~90 | 62~90 | 60~90 | 60~90 | 60~90 | |
| Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Ceiling Cassette Units can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my room?
For a space up to 550 sq ft, the Cooper & Hunter Hyper Heat 12,000 BTU indoor ceiling cassette is an ideal choice. Its capacity allows efficient cooling and heating for medium-sized rooms.
Can I install a mini split myself?
While some DIY enthusiasts tackle mini split installations, it is recommended to hire a professional for the Cooper & Hunter Hyper Heat system. Proper installation ensures optimal performance of the 12,000 BTU unit and compliance with local codes.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Hyper Heat unit comes pre-charged with R454B refrigerant for up to 25 ft of line set. This means you can install it with minimal additional refrigerant required for standard setups.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter Hyper Heat ductless mini split operates on 230V, making it compatible with standard residential electrical systems in many areas. Ensure your electrical setup matches this requirement for optimal performance.
What warranty does Cooper & Hunter offer on the Hyper Heat model?
The Cooper & Hunter Hyper Heat comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This warranty ensures peace of mind for your investment.
What is the SEER rating of the Cooper & Hunter Hyper Heat, and why is it important?
The Cooper & Hunter Hyper Heat boasts an impressive SEER rating of 22.6, indicating high energy efficiency. A higher SEER rating means lower energy costs and better performance, making it a smart choice for both heating and cooling.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Splits FAQ — Top Questions Answered for US Homeowners
2026 Master Resource Mini Splits FAQ: Top Questions US Homeowners Ask in 2026 Get definitive answers to your ductless heat...
Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control
Architectural Integration Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control I still remember a brutal custom build...
Why Buy from MiniSplitsForLess? Wholesale Prices and Top Deals
Behind the Pricing Why Buy from MiniSplitsForLess? Real Wholesale Pricing Without the Retail Games You’re about to click "Buy" on...






















