Cooper & Hunter MES 60,000 BTU Outdoor Condenser, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump

Cooper & Hunter

CH-R60MES-230VO
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 22
WiFi Not Included
Type Outdoor Unit
Freon R454B
Compressor Inverter
$4,356.00
Shipping Policy calculated at checkout.

Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:

  • Same Brand Only: Only pair with other same Brand and Series.
  • Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).

Mixing different brands or refrigerant types will cause the system to fail and void your warranty.

Pickup available at 3550 Northwest 113th Court

Usually ready in 2-4 days

FREE Armbridge Accessory With This Purchase

Choose one below — it will be added to your cart for free

Select your free accessory:

FREE
ARMBRIDGE AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base with Built-In Leveler
AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Zinc,...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Foldable 304 Stainless Steel, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Folda...
FREE
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity
Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets ...
FREE
ARMBRIDGE 18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, Anti-Slip Foundation for HVAC Systems and Outdoor Equipment
18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, ...
Free gift added to your cart!
Discount Banner
TrustScore 4.8

Olivia Wall Mount

The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.

Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.

Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

White air conditioner with purple shield logo and ’olivia’ text.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms
White air conditioning unit with black fan and copper tubing design.

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

White leather sectional sofa with modern design and clean lines.

Main Features

Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

Technical Specifications

Indoor and Outdoor Hyper

Indoor Model CH-R06MOLVWM-115VI CH-R09MOLVWM-230VI CH-R12MOLVWM-230VI CH-R18MOLVWM-230VI CH-R24MOLVWM-230VI CH-R33HEMLVWM-230VI
Power Supply Rated 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Btu/h 6,000 9,000 12,000 18,000 23,000 33,000
Minimum Circuit Ampacity (MCA) A 3 3 3 3 3 3
Max. Fuse A 3 3 3 3 3 3
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM 294.3/225.4/176.8/141.3/NA 382.6/293.1/194.2/153.0/NA 382.6/293.1/194.2/153.0/NA 759.3/530.4/419.1/382.6/NA 759.3/586.5/419.1/382.6/NA 829.6/716.6/592.7/447.3/NA
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) 42.0/37.0/32.0/24.0/NA 42.0/37.0/32.0/24.0/NA 43.0/37.0/32.0/24.0/NA 52.5/44.0/40.5/35.2/25.0 54.5/49.0/45.3/41.3/27.0 56.0/49.5/45.3/41.3/27.0
Dimension (WxDxH) inch 28.7x7.87x11.81 31.5x7.87x11.61 31.5x7.87x11.61 45.47x12.01x16.14 45.47x12.01x16.14 52.76x15.16x17.72
Packing (WxDxH) inch 31.10x10.63x14.76 34.45x11.22x14.96 34.45x11.22x14.96 45.47x12.01x16.14 45.47x12.01x16.14 52.76x15.16x17.72
Net/Gross Weight lbs. 17.64/21.35 18.64/22.05 18.64/22.05 45.47/21.06 45.47/21.06 67.16/17.72
Room temperature Cooling °F 60~90 60~90 60~90 60~90 60~90 60~90
Room temperature Heating °F 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 3/8" / 3/4"
Specification CH-RVHP19M-230VO CH-RVHP28M-230VO CH-RVHP36M-230VO CH-RVHP48M-230VO CH-RVHP55M-230VO
Power Supply (V/Ph/Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Operating Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Capacity (BTU/h) 5,400~28,000 7,200~37,000 9,000~43,000 12,000~57,000 19,000~59,000
SEER2 5.6 9.5 12 17.3 18.5
EER 15 12.5 13 12 12
IEER 25 23 23 23 22.2
Heating Capacity (BTU/h) 5,700~27,000 8,400~36,000 10,000~44,000 13,000~57,000 20,000~59,000
HSPF2 6.5 9.1 11.5 17.3 20.1
COP 4 3.8 4 3.7 3.5
SCOP 10.4 10.5 10.7 11 10.5
Power Input (W) 8.5 8.5 8.5 9 8.5
Air Flow (CFM) 19,000 27,000 36,000 47,000 47,000
Sound Level Indoor (dBA) 17.5 30 37 37 39.5
Sound Level Outdoor (dBA) 20 35 40 40 40
Weight Indoor (lbs) 2,130.7 2,148.4 3,037.2 4,502.8 4,502.8
Weight Outdoor (lbs) 61.5 61 65 65 65
Dimensions Indoor (in) 37.24x16.14x31.89 37.24x16.14x31.89 38.58x16.34x38.39 37.48x16.34x52.48 37.48x16.34x52.48
Dimensions Outdoor (in) 42.91x19.68x34.84 42.91x19.68x34.84 45.08x19.68x42.52 43.11x19.49x58.27 43.11x19.49x58.27
Shipping Weight Indoor/Outdoor (lbs) 137.35/148.15 168.43/179.67 211.86/244.71 246.47/276.68 246.47/276.68
Refrigerant Type/Amount (lbs) R454B/78.31 R454B/120.63 R454B/134.04 R454B/151.68 R454B/151.68
Fuse Size (A) 75 100 125 150 150
Wire Size (AWG) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Control Voltage (V) 550/340 550/340 550/340 550/340 550/340
Liquid Line 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Suction Line 3 x 3/8" 3 x 3/8" + 1 x 1/2" 3 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max Line Length (ft) 196.8 262.4 262.4 262.4 262.4
Max Elevation Diff (ft) 98.4 114.8 114.8 114.8 114.8
Max Head Pressure (ft) 49.2 49.2 49.2 49.2 49.2
Max Suction Pressure (ft) 33 33 33 33 33
Operating Range Cooling (°F) -22~122 -22~122 -22~122 -22~122 -22~122
Operating Range Heating (°F) -22~75 -22~75 -22~75 -22~75 -22~75
Feature 1
Feature 2
Feature 3
Feature 4

Indoor and Outdoor Regular

Indoor Model CH-R060LVWM-115VI CH-R09OLVWM-115VI CH-R120LVWM-115VI CH-RO9MOLVWM-230VI CH-R12MOLVWM-230VI CH-R18MOLVWM-230VI CH-R24MOLVWM-230VI CH-R30MELVWM-230VI CH-R36MELVWM-230VI
Power Supply Rated 115V, 1, 60 115V, 1, 60 115V, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Btu/h 7,000 9,000 12,000 9,000 12,000 18,000 24,000 30,000 36,000
Minimum Circuit Ampacity (MCA) A 3 3 3 3 3 3 3 3 3
Max. Fuse A 3 3 3 3 3 3 3 3 3
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM 370/340/265/174/- 378/340/265/174/- 378/340/265/174/- 382/294/194/153/- 382/294/194/153/- 759/530/419/382/- 759/586/419/382/- 871/716/547/447/- 871/716/547/447/-
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) 44/40/35/26/- 44/40/35/26/- 44/40/35/26/- 45/41/32/24/- 45/41/32/24/- 54/49/45/41/27 54/49/45/41/27 56/52/45/38/22 56/52/45/38/22
Dimension (WxDxH) inch 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 45.47x12.01x16.34 45.47x12.01x16.34 49.57x11.14x14.25 49.57x11.14x14.25
Packing (WxDxH) inch 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 42.91x19.09x34.84 42.91x19.09x34.84 42.91x19.09x34.84 42.91x19.09x34.84
Net/Gross Weight lbs. 18.64/22.05 18.64/22.05 18.64/22.05 18.64/22.05 18.64/22.05 45.47/21.06 45.47/21.06 67.16/17.72 67.16/17.72
Room temperature Cooling °F 60~90 60~90 60~90 60~90 60~90 60~90 60~90 60~90 60~90
Room temperature Heating °F 32~86 32~86 32~86 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 3/8" / 3/4" 3/8" / 3/4" 3/8" / 3/4" 3/8" / 3/4"
Specification CH-R18MES-230VO CH-R28MES-230VO CH-R36MES-230VO CH-R48MES-230VO CH-R60MES-230VO
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (range) (Btu/h) 5,400~21,600 7,200~32,000 9,000~42,000 12,000~55,000 19,000~62,000
Cooling Rated Current (A) 6 9.2 13.5 16.6 26.2
EER2 14 13 12 12.5 10
SEER2 25.1 25 24 24 22
Heating Rated Capacity (range) (Btu/h) 5,700~21,600 8,400~29,000 10,000~42,500 13,000~53,000 20,000~60,000
Heating Rated Current (A) 6.8 9.2 14 16.3 21
Heating at 47°F COP (W/W) 3.8 3.8 3.5 3.8 3.7
HSPF4 9.8 9.5 9.5 10.3 9.5
HSPF5 7.8 7 7 8 7.4
Heating at 5°F Rated Capacity (Btu/h) 13,500 19,000 26,000 36,000 39,000
Minimum Circuit Ampacity (Outdoor unit) (A) 16 23 30.5 40 40
Max. Fuse (Outdoor unit) (A) 20 25 35 45 45
Outdoor Air Flow (Max) (CFM) 1,765.8 2,130.7 2,148.4 4,502.8 4,502.8
Outdoor Noise Level (Sound Pressure) (dB(A)) 59.5 61 64.5 63 65
Dimension (W×D×H) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (W×D×H) (inch) 40.55x17.24x29.53 42.91x19.68x34.84 42.91x19.68x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs) 100.53/109.35 138.89/149.69 168.87/180.12 222.00/254.19 237.88/270.28
Refrigerant Type/Charged (oz) R454B/61.73 R454B/84.66 R454B/120.63 R454B/148.15 R454B/151.68
Refrigerant Precharge (ft) 75 100 125 150 150
Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32 0.16 / 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 3 x 1/4" 4 x 1/4" 5 x 1/4" 6 x 1/4" 6 x 1/4"
Refrigerant Piping Gas Side (inch) 3 x 3/8" 3 x 3/8" + 1 x 1/2" 4 x 3/8" + 1 x 1/2" 4 x 3/8" + 2 x 1/2" 4 x 3/8" + 2 x 1/2"
Max. Pipe Length (ft) 196.8 262.4 262.4 262.4 262.4
Max. Length for One Indoor Unit (ft) 98.4 114.8 114.8 114.8 114.8
Max. Height Difference in Level (ft) 49.2 49.2 49.2 49.2 49.2
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) -13~122 -13~122 -13~122 -13~122 -13~122
Ambient Temperature Heating (°F) -13~75 -13~75 -13~75 -13~75 -13~75
Certification: AHRI
Certification: Energy Star
Certification: NEEP
Certification: ETL

Multiple Control Methods

Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

What size mini split do I need for my space?

For areas up to 2,500 sq ft, the Cooper & Hunter MES 60,000 BTU outdoor condenser is suitable. This unit provides ample cooling and heating capacity for larger rooms or open spaces.

How much does a mini split system like the Cooper & Hunter MES cost?

Pricing for the Cooper & Hunter MES 60,000 BTU mini split can vary based on installation options, typically ranging from $2,000 to $5,000. Be sure to consider additional costs for installation kits if needed.

Can I install a mini split myself?

While a DIY installation of the Cooper & Hunter MES 60,000 BTU system is possible, it may require technical knowledge, especially with refrigerant handling. Professional installation is recommended to ensure optimal performance and compliance with local codes.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter MES 60,000 BTU unit is pre-charged with R454B refrigerant for up to 25 ft of line set, which simplifies the installation process. Always check the manufacturer's guidelines to ensure proper installation.

What voltage does the Cooper & Hunter MES mini split require?

The Cooper & Hunter MES 60,000 BTU outdoor condenser operates on 230V, making it compatible with most residential electrical systems. Ensure your installation site has the appropriate voltage supply.

What warranty does the Cooper & Hunter MES offer?

The Cooper & Hunter MES 60,000 BTU system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This gives you peace of mind regarding your investment.