Cooper & Hunter Olivia 36,000 BTU Indoor Wall Mount, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump | No Kit

Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Type | |
| Freon | |
| Compressor |
⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:
- Same Brand Only: Only pair with other same Brand and Series.
- Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).
Mixing different brands or refrigerant types will cause the system to fail and void your warranty.
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Wall Mount
The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.
Technical Specifications
INDOOR MODELS HYPER
| Indoor Model | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my home?
For optimal performance, the Cooper & Hunter Olivia 36,000 BTU mini split is ideal for spaces up to 1500 sq ft. This model's capacity ensures sufficient cooling or heating for larger rooms or open areas.
Can I install a mini split myself?
While some homeowners may attempt a DIY installation, it's important to note that the Cooper & Hunter Olivia requires proper knowledge of HVAC systems for optimal performance. If you're not experienced, consider hiring a professional to ensure the system operates efficiently.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia mini split comes pre-charged with R410A refrigerant for up to 25 ft of line set. This feature simplifies installation and ensures that the system is ready for use once properly set up.
What voltage does a mini split require?
The Cooper & Hunter Olivia operates on a 230V electrical system, making it compatible with most residential setups. Ensure your electrical supply meets this requirement before installation.
What warranty does Cooper & Hunter offer for the Olivia mini split?
The Cooper & Hunter Olivia comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of purchase. This warranty offers peace of mind for your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter Olivia boasts an impressive SEER rating of 26.4, which is well above the minimum efficiency standards. This high efficiency can lead to significant energy savings over time, making it an excellent choice for eco-conscious consumers.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026
2026 Climate Solution Guide Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026 Most homeowners know...
Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins?
Buyer's Guide • Cooling Systems Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins? You measured the...
How Much Square Footage Can a 24,000 BTU Mini Split Cool?
Complete Sizing Guide How Much Square Footage Can a 24,000 BTU Mini Split Cool? You’ve measured your great room. You’ve...






















