Cooper & Hunter Olivia Hyper 48,000 BTU 3-Zone 6k+12k+30k Wall Mount, 230V, R454B - Ductless Mini Split AC Heat Pump | No Kit No Kit No Kit








Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated
Pickup available at Medley Warehouse
Usually ready in 24 hours
Mon–Fri, 9:00 AM – 4:30 PM
Questions about this system?
Answers in seconds — tap a question below
-
Covers about 1800–2400 sq ft total, split across its indoor units — each head handles its own room, so you put the right capacity where you need it. Rule of thumb: ~20 BTU per sq ft, and 12,000 BTU = 1 ton (this system is 48,000 BTU (4-ton)). Want help splitting the zones? Our team can map it out.
-
12,000 BTU = 1 ton — "tons" is just the older way of stating capacity. So 24,000 BTU = 2 tons, 36,000 = 3 tons, and so on. This system is 48,000 BTU (4-ton). BTU tells you the capacity; SEER2 tells you the efficiency.
-
It uses R454B — the newest low-GWP eco refrigerant, so it's future-proof and efficient. The outdoor unit ships pre-charged for a standard line set, so most installs need no extra refrigerant; your licensed, EPA-608-certified installer verifies the charge and tops it off if your line set is longer.
-
Rated SEER2 23.0 — a strong efficiency number, and the higher it is the lower your energy bills. Its inverter compressor ramps up and down instead of cycling on/off, so it holds the temperature steadily, runs quietly, and uses less power than a standard AC or window unit.
-
Needs a dedicated 230V circuit, like a large household appliance, so it can deliver full capacity to larger rooms and multi-zone setups. Your licensed HVAC installer or electrician sets up the correct breaker and disconnect to meet local electrical code.
-
Yes — a big upgrade. It's far more efficient (inverter, SEER2 23.0) and much quieter, since the compressor sits outside instead of in your window or on the floor. It mounts permanently, doesn't block a window, and heats as well as cools year-round. Higher upfront cost, but lower bills and a longer lifespan.
-
Yes to all three. It's an inverter heat pump — cools in summer, heats in winter (even in the cold), far more efficiently than electric heaters. A Dry mode also pulls out humidity, so rooms feel cooler and less muggy.
-
Yes. Each indoor unit has its own remote/thermostat — set different temperatures or turn one off, so you only condition the rooms you use and save energy on the ones you're not. One outdoor unit powers them all, keeping install and running costs lower than separate systems per room.
-
Yes — WiFi is included, so you can set schedules, change the temperature, and even turn it on before you get home, all from the mobile app (and pair it with voice assistants). A standard remote is included too.
-
Ships as a complete set: CH-RHP48M-230VO, CH-R06MOLVWM-230VI, CH-R12MOLVWM-230VI, CH-R30MELVWM-230VI. Everything arrives together — check the photos and specs for the full kit.
-
It should be installed by a licensed, EPA-608-certified HVAC professional — we don't recommend DIY installation. Handling refrigerant requires EPA Section 608 certification under U.S. law, and professional installation keeps the system safe, code-compliant, and your manufacturer warranty valid.
-
Yes — you get full inverter heat-pump technology and the same core features as premium brands without paying for the name, which is how we keep prices low. Shipping is free on U.S. orders over $300, and our team can help with sizing and support.
Why buy this mini split from MiniSplitsForLess
- Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Complete 3-Zone System
Heat or cool 3 rooms independently from one 48000 BTU Olivia outdoor unit (6K+12K+30K) — every zone sets its own temperature, delivered by wall mount indoor units.
Inverter Efficiency — SEER2 23
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 23 on 230V — steady comfort with noticeably lower energy bills.
Right-Sized Coverage
Engineered to heat & cool up to 1800–2400 sq ft across 3 zones — matched capacity so you never over- or under-size the space.
Olivia Wall Mount
The Cooper&Hunter Olivia Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor Unit Specs CH-R06MOLVWM-230VI
| Model | CH-R06MOLVWM-230VI |
|---|---|
| Unit Dimensions (WxDxH) | 28.70 x 7.87 x 11.50 in |
| Net/Gross Weight | 17.64/23.15 lb |
| Packing Dimensions (WxDxH) | 31.10 x 10.63 x 14.76 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" |
| Noise Level (Hi/Med/Lo) | 37/32/24 dB |
| Dehumidification | 0.63 pt/h |
| Drain Pipe Diameter | 5/8" |
| Controller | remote controller |
Indoor Unit Specs CH-R12MOLVWM-230VI
| Model | CH-R12MOLVWM-230VI |
|---|---|
| Unit Dimensions (WxDxH) | 31.57 x 7.87 x 11.61 in |
| Net/Gross Weight | 18.96/24.25 lb |
| Packing Dimensions (WxDxH) | 34.45 x 11.22 x 14.96 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" |
| Noise Level (Hi/Med/Lo) | 42/35.5/22.5 dB |
| Dehumidification | 2.96 pt/h |
| Drain Pipe Diameter | 5/8" |
| Controller | remote controller |
Indoor Unit Specs CH-R30MELVWM-230VI
| Model | CH-R30MELVWM-230VI |
|---|---|
| Unit Dimensions (WxDxH) | 49.57 x 11.14 x 14.25 in |
| Net/Gross Weight | 43.43/56.88 lb |
| Packing Dimensions (WxDxH) | 52.76 x 17.72 x 15.16 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 3/8"/5/8" |
| Noise Level (Hi/Med/Lo) | 52/45/36 dB |
| Dehumidification | 7.61 pt/h |
| Drain Pipe Diameter | 5/8" |
| Controller | remote controller |
Outdoor Unit Specs CH-RHP48M-230VO
| Model | CH-RHP48M-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 in |
| Net/Gross Weight | 246.47/276.68 lb |
| Packing Dimensions (WxDxH) | 43.11 x 19.49 x 58.27 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 45 A |
| Min. Circuit Ampacity | 43 A |
| Copper Line Size (Liquid/Gas) | 6x1/4" - 4x3/8"+2x1/2" |
| Noise Level | 65 dB |
| Airflow | 4,502.8 CFM |
| Dehumidification | 9.30 pt/h |
System Specs
| Cooling Capacity | 48,000 BTU |
|---|---|
| SEER2 | 23 |
| Zones | 3 |
| Voltage | 230V |
| Refrigerant Type | R454B |
| Compressor | Inverter |
| WiFi | Included |
| Heating Capacity | 49,000(13,000~57,000) BTU/h |
| Cooling Capacity Range | 47,000(12,000~57,000) BTU/h |
| Operating Range (Cooling) | -22~122 °F |
| Operating Range (Heating) | -22~75 °F |
| Refrigerant Precharge | 150 ft |
| Max Height Difference | 49.2 ft |
| COP | 3.7 |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor and Outdoor Hyper
| Indoor Model | CH-R06MOLVWM-115VI | CH-R09MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R33HEMLVWM-230VI |
|---|---|---|---|---|---|---|
| Power Supply Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 6,000 | 9,000 | 12,000 | 18,000 | 23,000 | 33,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 294.3/225.4/176.8/141.3/NA | 382.6/293.1/194.2/153.0/NA | 382.6/293.1/194.2/153.0/NA | 759.3/530.4/419.1/382.6/NA | 759.3/586.5/419.1/382.6/NA | 829.6/716.6/592.7/447.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 42.0/37.0/32.0/24.0/NA | 42.0/37.0/32.0/24.0/NA | 43.0/37.0/32.0/24.0/NA | 52.5/44.0/40.5/35.2/25.0 | 54.5/49.0/45.3/41.3/27.0 | 56.0/49.5/45.3/41.3/27.0 |
| Dimension (WxDxH) inch | 28.7x7.87x11.81 | 31.5x7.87x11.61 | 31.5x7.87x11.61 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Packing (WxDxH) inch | 31.10x10.63x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Net/Gross Weight lbs. | 17.64/21.35 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| Rated Current | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER2 | 15 | 12.5 | 13 | 12 | 12 |
| SEER2 | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Indoor and Outdoor Regular
| Indoor Model | CH-R060LVWM-115VI | CH-R09OLVWM-115VI | CH-R120LVWM-115VI | CH-RO9MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R30MELVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated | 115V, 1, 60 | 115V, 1, 60 | 115V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 370/340/265/174/- | 378/340/265/174/- | 378/340/265/174/- | 382/294/194/153/- | 382/294/194/153/- | 759/530/419/382/- | 759/586/419/382/- | 871/716/547/447/- | 871/716/547/447/- |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 44/40/35/26/- | 44/40/35/26/- | 44/40/35/26/- | 45/41/32/24/- | 45/41/32/24/- | 54/49/45/41/27 | 54/49/45/41/27 | 56/52/45/38/22 | 56/52/45/38/22 |
| Dimension (WxDxH) inch | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 45.47x12.01x16.34 | 45.47x12.01x16.34 | 49.57x11.14x14.25 | 49.57x11.14x14.25 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
What’s Included
| Outdoor condenser | CH-RHP48M-230VO |
|---|---|
| Indoor unit | CH-R06MOLVWM-230VI |
| Indoor unit | CH-R12MOLVWM-230VI |
| Indoor unit | CH-R30MELVWM-230VI |
| Remote controller | remote controller |
Installation kit is not included in the selected option — pick 16ft, 25ft or 50ft above to add one.
Shipping & Returns
- Free shipping on every order over $300.
- Delivery estimate for your ZIP is shown in the buy box above.
- Returns accepted per our policy — unopened units in original packaging.
Warranty
7-year compressor / 5-year parts
- Limited manufacturer warranty on the compressor and sealed system components.
- Your order number is the proof of purchase — keep it for any claim.
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Room Air Conditioner Noise Levels: dB Testing Against 110V Mini Splits
Acoustic Testing Data Room Air Conditioner Noise Levels: My dB Test of a Window Unit vs. a 110V Mini Split...
Ducted Mini Split Airflow Specs: Real Static Pressure Data
HVAC Design Reference Ducted Mini Split Static Pressure & Airflow: What the Spec Sheets Don't Tell You Duct Design Mechanics...
PTAC Unit vs Mini Split: Noise, Efficiency & Cost Breakdown
Hospitality HVAC Guide PTAC vs Mini Split for Hotels: Real Noise, Efficiency & Cost Test (2026) Acoustic Tests Energy Comparisons...