Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Olivia Midnight Wall Mount
The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter’s Olivia Midnight Series units are specifically designed to provide maximum comfort in smaller spaces. Featuring advanced inverter technology, these units deliver energy-efficient heating and cooling, while quiet operation ensures a peaceful environment. With precise airflow control and seamless integration into any interior, the Olivia Midnight Series offers reliable, consistent comfort in even the tightest spaces.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor HYPER
| Specification | CH-RB06MOLVWM-230VI | CH-RB09MOLVWM-230VI | CH-RB12MOLVWM-230VI | CH-RB18MOLVWM-230VI | CH-RB24MOLVWM-230VI |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity | 6,000 Btu/h | 9,000 Btu/h | 12,000 Btu/h | 18,000 Btu/h | 23,000 Btu/h |
| Minimum Circuit Ampacity (MCA) | 3 A | 3 A | 3 A | 3 A | 3 A |
| Max. Fuse | 15 A | 15 A | 15 A | 15 A | 15 A |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 294.3/235.4/176.6/141.3/ \A | 382.6/294.3/194.2/153.0/NA | 382.6/294.3/194.2/153.0 / / | 759.3/500.3/441.4/ 370.8 / / | 799.3/588.6/459.1/ 382.6 / / |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | 42/37/32/24/20 dB(A) | N\A/38.5/33/24/20.5 dB(A) | N\A/42/35.5/22.5/20 dB(A) | 54.5/45/40/24.5/20 dB(A) | 54.5/45.5/43.5/34.5/20.5 dB(A) |
| Indoor | |||||
| Dimension (WxDxH) | 28.70x7.87x11.50 inch | 31.57x7.87x11.61 inch | 31.57x7.87x11.61 inch | 42.60x9.21x13.27 inch | 42.60x9.21x13.27 inch |
| Packing (WxDxH) | 31.10x10.63x14.76 inch | 34.45x11.22x14.96 inch | 34.45x11.22x14.96 inch | 45.47x12.40x16.34 inch | 45.47x12.40x16.34 inch |
| Net/Gross Weight | 17.64/23.15 lbs. | 18.96/24.25 lbs. | 18.96/24.25 lbs. | 30.42/39.68 lbs. | 30.86/40.56 lbs. |
| Room temperature | |||||
| Cooling | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F |
| Heating | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter Olivia Midnight 36,000 BTU system cool?
The Cooper & Hunter Olivia Midnight 36,000 BTU mini split system can effectively cool up to two rooms, given its dual-zone capability. With a coverage area of up to 1500 sq ft, it is ideal for larger spaces or multiple smaller rooms.
Can I mix different BTU sizes with the Cooper & Hunter Olivia Midnight system?
Yes, you can mix different BTU sizes in a multi-zone system like the Cooper & Hunter Olivia Midnight. However, ensure that the total BTU does not exceed the 36,000 BTU capacity to maintain efficiency and performance.
Do all zones run simultaneously with the Cooper & Hunter Olivia Midnight?
In the Cooper & Hunter Olivia Midnight system, all zones can run simultaneously, allowing you to cool or heat multiple areas at once. This flexibility is beneficial for maintaining comfort across different living spaces.
Is the Cooper & Hunter Olivia Midnight system more efficient than multiple single-zone units?
With a SEER rating of 23.9, the Cooper & Hunter Olivia Midnight system offers superior efficiency compared to using multiple single-zone units. This enhanced efficiency can lead to lower energy bills and better climate control for your entire home.
What are the warranty terms for the Cooper & Hunter Olivia Midnight?
The Cooper & Hunter Olivia Midnight comes with a 5-year parts warranty and a 7-year compressor warranty, provided that registration is completed within 30 days of purchase. This warranty ensures long-term reliability for your investment.
Does the Cooper & Hunter Olivia Midnight come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia Midnight mini split is pre-charged with refrigerant, allowing for straightforward installation with up to 25 ft of line set. This feature helps streamline the setup process and ensures optimal performance right out of the box.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control
Architectural Integration Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control I still remember a brutal custom build...
Why Buy from MiniSplitsForLess? Wholesale Prices and Top Deals
Behind the Pricing Why Buy from MiniSplitsForLess? Real Wholesale Pricing Without the Retail Games You’re about to click "Buy" on...
Mini Splits for Older Homes Without Ductwork: The Complete 2026 Retrofit Guide
The 2026 Retrofit Guide Mini Splits for Older Homes Without Ductwork Look, I love old homes. I’ve spent more weekends...