Cooper & Hunter Olivia Midnight 5 Zone 36,000 BTU Wall Mount Mini Split AC/Heat Pump 9K+9K+9K+9K+9K - R454B | No Kit



Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Olivia Midnight Wall Mount
The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter’s Olivia Midnight Series units are specifically designed to provide maximum comfort in smaller spaces. Featuring advanced inverter technology, these units deliver energy-efficient heating and cooling, while quiet operation ensures a peaceful environment. With precise airflow control and seamless integration into any interior, the Olivia Midnight Series offers reliable, consistent comfort in even the tightest spaces.
All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.
Technical Specifications
Indoor HYPER
| Specification | CH-RB06MOLVWM-230VI | CH-RB09MOLVWM-230VI | CH-RB12MOLVWM-230VI | CH-RB18MOLVWM-230VI | CH-RB24MOLVWM-230VI |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity | 6,000 Btu/h | 9,000 Btu/h | 12,000 Btu/h | 18,000 Btu/h | 23,000 Btu/h |
| Minimum Circuit Ampacity (MCA) | 3 A | 3 A | 3 A | 3 A | 3 A |
| Max. Fuse | 15 A | 15 A | 15 A | 15 A | 15 A |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 294.3/235.4/176.6/141.3/ \A | 382.6/294.3/194.2/153.0/NA | 382.6/294.3/194.2/153.0 / / | 759.3/500.3/441.4/ 370.8 / / | 799.3/588.6/459.1/ 382.6 / / |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | 42/37/32/24/20 dB(A) | N\A/38.5/33/24/20.5 dB(A) | N\A/42/35.5/22.5/20 dB(A) | 54.5/45/40/24.5/20 dB(A) | 54.5/45.5/43.5/34.5/20.5 dB(A) |
| Indoor | |||||
| Dimension (WxDxH) | 28.70x7.87x11.50 inch | 31.57x7.87x11.61 inch | 31.57x7.87x11.61 inch | 42.60x9.21x13.27 inch | 42.60x9.21x13.27 inch |
| Packing (WxDxH) | 31.10x10.63x14.76 inch | 34.45x11.22x14.96 inch | 34.45x11.22x14.96 inch | 45.47x12.40x16.34 inch | 45.47x12.40x16.34 inch |
| Net/Gross Weight | 17.64/23.15 lbs. | 18.96/24.25 lbs. | 18.96/24.25 lbs. | 30.42/39.68 lbs. | 30.86/40.56 lbs. |
| Room temperature | |||||
| Cooling | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F |
| Heating | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter Olivia Midnight 5 Zone system cool?
The Cooper & Hunter Olivia Midnight 5 Zone mini split can effectively cool or heat up to five separate rooms, making it ideal for homes or spaces up to 1,500 sq ft with a total capacity of 36,000 BTU.
Can I mix BTU sizes with the Cooper & Hunter Olivia Midnight system?
While the Cooper & Hunter Olivia Midnight model operates at a total of 36,000 BTU, you can mix smaller BTU sizes for each zone, such as 9K for each of the five zones, ensuring balanced heating and cooling based on your specific needs.
Do all zones run simultaneously in the Cooper & Hunter multi-zone mini split?
Yes, the Cooper & Hunter Olivia Midnight system allows each of the five zones to operate independently, which means you can choose to run all zones simultaneously or only the ones currently needed for heating or cooling.
Is the Cooper & Hunter Olivia Midnight mini split good for heating in cold weather?
The Cooper & Hunter Olivia Midnight, with a SEER rating of 24.0 and using R454B refrigerant, is designed to efficiently provide heating even in colder temperatures, making it a reliable option for year-round comfort.
What warranty does the Cooper & Hunter Olivia Midnight offer?
The Cooper & Hunter Olivia Midnight comes with a 5-year parts warranty and a 7-year compressor warranty, but remember that registration is required within 30 days of purchase to activate these terms.
Does the Cooper & Hunter Olivia Midnight mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia Midnight mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, simplifying installation for users and ensuring optimal performance right from the start.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026
2026 Climate Solution Guide Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026 Most homeowners know...
Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins?
Buyer's Guide • Cooling Systems Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins? You measured the...
How Much Square Footage Can a 24,000 BTU Mini Split Cool?
Complete Sizing Guide How Much Square Footage Can a 24,000 BTU Mini Split Cool? You’ve measured your great room. You’ve...