Cooper & Hunter Olivia Midnight 60,000 BTU 2-Zone 24k+24k Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump | No Kit No Kit






Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Olivia Midnight Wall Mount
The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter’s Olivia Midnight Series units are specifically designed to provide maximum comfort in smaller spaces. Featuring advanced inverter technology, these units deliver energy-efficient heating and cooling, while quiet operation ensures a peaceful environment. With precise airflow control and seamless integration into any interior, the Olivia Midnight Series offers reliable, consistent comfort in even the tightest spaces.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor HYPER
| Specification | CH-RB06MOLVWM-230VI | CH-RB09MOLVWM-230VI | CH-RB12MOLVWM-230VI | CH-RB18MOLVWM-230VI | CH-RB24MOLVWM-230VI |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity | 6,000 Btu/h | 9,000 Btu/h | 12,000 Btu/h | 18,000 Btu/h | 23,000 Btu/h |
| Minimum Circuit Ampacity (MCA) | 3 A | 3 A | 3 A | 3 A | 3 A |
| Max. Fuse | 15 A | 15 A | 15 A | 15 A | 15 A |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 294.3/235.4/176.6/141.3/ \A | 382.6/294.3/194.2/153.0/NA | 382.6/294.3/194.2/153.0 / / | 759.3/500.3/441.4/ 370.8 / / | 799.3/588.6/459.1/ 382.6 / / |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | 42/37/32/24/20 dB(A) | N\A/38.5/33/24/20.5 dB(A) | N\A/42/35.5/22.5/20 dB(A) | 54.5/45/40/24.5/20 dB(A) | 54.5/45.5/43.5/34.5/20.5 dB(A) |
| Indoor | |||||
| Dimension (WxDxH) | 28.70x7.87x11.50 inch | 31.57x7.87x11.61 inch | 31.57x7.87x11.61 inch | 42.60x9.21x13.27 inch | 42.60x9.21x13.27 inch |
| Packing (WxDxH) | 31.10x10.63x14.76 inch | 34.45x11.22x14.96 inch | 34.45x11.22x14.96 inch | 45.47x12.40x16.34 inch | 45.47x12.40x16.34 inch |
| Net/Gross Weight | 17.64/23.15 lbs. | 18.96/24.25 lbs. | 18.96/24.25 lbs. | 30.42/39.68 lbs. | 30.86/40.56 lbs. |
| Room temperature | |||||
| Cooling | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F |
| Heating | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter Olivia Midnight 60,000 BTU mini split cool?
The Cooper & Hunter Olivia Midnight with 60,000 BTU capacity is designed to efficiently cool or heat up to 2,500 sq ft, making it suitable for multiple rooms depending on their size and insulation.
Can I mix BTU sizes with the Cooper & Hunter Olivia Midnight 2-Zone system?
Yes, you can mix BTU sizes in a multi-zone system like the Cooper & Hunter Olivia Midnight; however, it's recommended to maintain a balance in load to ensure optimal performance. For instance, you can pair a 24k BTU unit with another 24k BTU unit.
Do all zones run simultaneously in the Cooper & Hunter Olivia Midnight mini split?
In the Cooper & Hunter Olivia Midnight multi-zone setup, all zones can run simultaneously, allowing you to maintain different temperatures in different areas of your home, which enhances comfort and efficiency.
How does the efficiency of the Cooper & Hunter Olivia Midnight compare to using multiple single-zone units?
The Cooper & Hunter Olivia Midnight boasts a 22.0 SEER rating, which provides superior energy efficiency compared to operating multiple single-zone units, ultimately leading to lower energy costs and improved comfort across larger spaces.
What warranty does the Cooper & Hunter Olivia Midnight offer?
The Cooper & Hunter Olivia Midnight offers a 5-year parts warranty and a 7-year compressor warranty, provided that registration is completed within 30 days of installation.
Does the Cooper & Hunter Olivia Midnight mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia Midnight mini split comes pre-charged with R454B refrigerant for up to 25 ft of line set, simplifying the installation process and ensuring optimal performance right out of the box.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Splits for Older Homes Without Ductwork: The Complete 2026 Retrofit Guide
The 2026 Retrofit Guide Mini Splits for Older Homes Without Ductwork Look, I love old homes. I’ve spent more weekends...
36,000 BTU Mini Split: The Honest 3-Ton Buying Guide
Expert Buying Guide 36,000 BTU Mini Split: The Honest 3-Ton Buying Guide A few years ago, I got called out...
6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide)
2026 HVAC Guide 6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide) I used to think bigger...
































