| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Type | |
| Freon | |
| Compressor |
⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:
- Same Brand Only: Only pair with other same Brand and Series.
- Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).
Mixing different brands or refrigerant types will cause the system to fail and void your warranty.
Pickup currently unavailable at 3550 Northwest 113th Court
Questions about this system?
Answers in seconds — tap a question below
-
Sized for about the room's square footage at ~20 BTU per sq ft. Rule of thumb: ~20 BTU per sq ft, and 12,000 BTU = 1 ton (this unit is 24,000 BTU (2-ton)). Ceiling height, insulation, sun and climate shift that — if you're between sizes, size up for hot/humid rooms. Not sure? We'll confirm the right BTU for your space.
-
12,000 BTU = 1 ton — "tons" is just the older way of stating capacity. So 24,000 BTU = 2 tons, 36,000 = 3 tons, and so on. This system is 24,000 BTU (2-ton). BTU tells you the capacity; SEER2 tells you the efficiency.
-
It uses R410A — a proven, widely serviced refrigerant. The outdoor unit ships pre-charged for a standard line set, so most installs need no extra refrigerant; your licensed, EPA-608-certified installer verifies the charge and tops it off if your line set is longer.
-
Rated SEER2 23.0 — a strong efficiency number, and the higher it is the lower your energy bills. Its inverter compressor ramps up and down instead of cycling on/off, so it holds the temperature steadily, runs quietly, and uses less power than a standard AC or window unit.
-
Needs a dedicated 230V circuit, like a large household appliance, so it can deliver full capacity to larger rooms and multi-zone setups. Your licensed HVAC installer or electrician sets up the correct breaker and disconnect to meet local electrical code.
-
Yes — a big upgrade. It's far more efficient (inverter, SEER2 23.0) and much quieter, since the compressor sits outside instead of in your window or on the floor. It mounts permanently, doesn't block a window, and heats as well as cools year-round. Higher upfront cost, but lower bills and a longer lifespan.
-
Yes to all three. It's an inverter heat pump — cools in summer, heats in winter (even in the cold), far more efficiently than electric heaters. A Dry mode also pulls out humidity, so rooms feel cooler and less muggy.
-
Yes — WiFi is not included, so you can set schedules, change the temperature, and even turn it on before you get home, all from the mobile app (and pair it with voice assistants). A standard remote is included too.
-
Ships as a complete set: CH-24MOLVWM-230VI. Everything arrives together — check the photos and specs for the full kit.
-
It should be installed by a licensed, EPA-608-certified HVAC professional — we don't recommend DIY installation. Handling refrigerant requires EPA Section 608 certification under U.S. law, and professional installation keeps the system safe, code-compliant, and your manufacturer warranty valid.
-
Yes — you get full inverter heat-pump technology and the same core features as premium brands without paying for the name, which is how we keep prices low. Shipping is free on U.S. orders over $300, and our team can help with sizing and support.
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Why buy this mini split from MiniSplitsForLess
- Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Floor & Ceiling Flexibility
Mounts low on the wall or up near the ceiling — a versatile fit for rooms where a standard wall unit won't work, sized at 24000 BTU.
Inverter Efficiency — SEER2 23
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 23 on 230V — steady comfort with noticeably lower energy bills.
Smart Wi-Fi Control
Wi-Fi is not included — set schedules and adjust the temperature from your phone anywhere, or pair with Alexa & Google Home.
Universal Floor Ceiling
Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.
Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.
Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.
Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

Technical Specifications
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W | |
|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | |
| Rated Capacity Cooling (Btu/h) | 18,000 | 24,000 | 36,000 | 48,000 | 54,000 | |
| Rated Capacity Heating (Btu/h) | 20,000 | 24,000 | 38,000 | 50,000 | 60,000 | |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 | |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/1,118/1,000 | 1,430/1,384/1,029/795 | |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 47/43.5/40.5 | 51/47/42 | 51.5/48.0/40.5 | 55/49.5/44.5 | 55/48/42 | |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 | |
| Indoor Packing (WxDxH) (inch) | 45.08x29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 | |
| Room Temperature Cooling (°F) | 62~90 | 62~90 | 62~90 | 62~90 | 62~90 | |
| Room Temperature Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" | |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
INDOOR MODELS HYPER
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity Cooling (Btu/h) | 17,000 | 24,000 | 36,000 | 48,000 | 55,000 |
| Rated Capacity Heating (Btu/h) | 18,000 | 25,000 | 39,000 | 51,000 | 60,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/ 1,118/1,000 | 1,430/1,384/1,029/795 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 45.5/43/39 | 51/47.5/42 | 52.5/48.5/42.5 | 55/50/44 | 54/47/44 |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 |
| 45.08×29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 |
| Room Temperature (°F) | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62 ~ 90 | Cooling: 62~ 90 |
| Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" |
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my home?
For optimal performance, the Cooper & Hunter SPH 24,000 BTU unit is designed to cover areas up to 1200 sq ft. Ensure you calculate your room size to confirm that this capacity aligns with your heating and cooling needs.
Can I install a mini split myself or do I need a professional?
While some homeowners may attempt a DIY installation, it is recommended to hire a professional for the Cooper & Hunter SPH 24,000 BTU unit to ensure proper setup and compliance with local codes. Incorrect installation can lead to inefficiencies or damage.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter SPH 24,000 BTU mini split comes pre-charged with R410A refrigerant for up to 25 ft of line set, making installation easier. However, adjustments may be necessary depending on your specific installation requirements.
What voltage does the Cooper & Hunter SPH mini split require?
The Cooper & Hunter SPH 24,000 BTU unit operates on a 230V electrical system, making it suitable for standard residential installations. Ensure your home's electrical system can support this voltage before purchasing.
What warranty does Cooper & Hunter offer on this mini split?
The Cooper & Hunter SPH 24,000 BTU mini split comes with a solid warranty: 5-year parts and 7-year compressor warranty, provided you register the unit within 30 days of installation. This warranty adds confidence in your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter SPH 24,000 BTU unit boasts a SEER rating of 23.0, which is highly efficient and exceeds the minimum requirements for energy savings. A higher SEER rating indicates better efficiency, potentially lowering your energy costs.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split AC Delivery & Wholesale Terms: Shipping Times for Contractors
B2B Logistics & Freight Mini Split AC Delivery & Wholesale Terms: Shipping Times, Freight Costs & Contractor Bulk Pricing (2026)...
Mini Split Sale & Clearance Deals: Discounted Heat Pumps
Sale & Clearance Mini Split Sale & Clearance Guide: How to Find Genuine Discounts Live Markdowns Factory-Sealed Stock Fast Shipping...
Small Mini Split Dimensions: Exact Wall Clearances for Tight Spaces
Measured Guide 2026 Compact Mini Split Installs: Verified Clearance Specs for Tight Walls When inches matter, Minisplitsforless.com delivers exact clearances...