Product specifications
SEER 23
Compressor Inverter
Brand Cooper & Hunter
Voltage 230V
WiFi Not Included
Type Universal Floor/Ceiling
Freon R410A
$714.00 Sold out
Shipping Policy calculated at checkout.
Store rating: 4.5 Trustpilot (590) 4.6 Google (522)
Installation Kit: No Installation Kit

⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:

  • Same Brand Only: Only pair with other same Brand and Series.
  • Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).

Mixing different brands or refrigerant types will cause the system to fail and void your warranty.

Availability

Out of stock right now
For the next arrival, call (855) 775-4822.

How do you want to get it?

— we’ll fill in your ZIP. Used only for delivery dates and pickup.

FREE shipping to We don’t ship to .Pick up at ·

Choose a pickup warehouse

Cooper & Hunter SPH 24,000 BTU Indoor Multi Zone Universal Floor/Ceiling, 230V, R410A - Ductless Mini Split Air Conditioner Heat PumpNo Installation Kit · Qty 1

Closest to first

— we’ll fill in your ZIP. Used only for delivery dates and pickup.

Pickup warehouses

Stock is checked again at checkout. Buying 2 or more? Checkout confirms the warehouse has them all.

Questions? (855) 775-4822

Mon–Fri 9–5 ET

Delivery dates are estimates

Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated

Questions about this system?

Answers in seconds — tap a question below

  • Up to about 1,100 sq ft at average conditions. We size at about 22 BTU per sq ft, more conservative than the ENERGY STAR room-size chart. Add capacity for a hot climate, ceilings over 8 ft, strong sun (+10%), a kitchen (+4,000 BTU) or each person over two (+600 BTU). For a room-by-room load calculation, ask your installer for an ACCA Manual J. Not sure? Call (855) 775-4822 and we'll confirm the right size for your space.
  • 12,000 BTU = 1 ton — "tons" is just the older way of stating capacity. So 24,000 BTU = 2 tons, 36,000 = 3 tons, and so on. This system is 24,000 BTU (2-ton). BTU tells you the capacity; SEER2 tells you the efficiency.
  • It uses R410A — a proven, widely serviced refrigerant. The outdoor unit ships pre-charged for a standard line set, so most installs need no extra refrigerant; your licensed, EPA-608-certified installer verifies the charge and tops it off if your line set is longer.
  • Rated SEER2 23.0 — a strong efficiency number, and the higher it is the lower your energy bills. Its inverter compressor ramps up and down instead of cycling on/off, so it holds the temperature steadily, runs quietly, and uses less power than a standard AC or window unit.
  • Needs a dedicated 230V circuit, like a large household appliance, so it can deliver full capacity to larger rooms and multi-zone setups. Your licensed HVAC installer or electrician sets up the correct breaker and disconnect to meet local electrical code.
  • Yes — a big upgrade. It's far more efficient (inverter, SEER2 23.0) and much quieter, since the compressor sits outside instead of in your window or on the floor. It mounts permanently, doesn't block a window, and heats as well as cools year-round. Higher upfront cost, but lower bills and a longer lifespan.
  • Yes to all three. It's an inverter heat pump — cools in summer, heats in winter (even in the cold), far more efficiently than electric heaters. A Dry mode also pulls out humidity, so rooms feel cooler and less muggy.
  • Yes — WiFi is not included, so you can set schedules, change the temperature, and even turn it on before you get home, all from the mobile app (and pair it with voice assistants). A standard remote is included too.
  • Ships as a complete set: CH-24MSPHFC-230VI. Everything arrives together — check the photos and specs for the full kit.
  • It should be installed by a licensed, EPA-608-certified HVAC professional — we don't recommend DIY installation. Handling refrigerant requires EPA Section 608 certification under U.S. law, and professional installation keeps the system safe, code-compliant, and your manufacturer warranty valid.
  • Yes — you get full inverter heat-pump technology and the same core features as premium brands without paying for the name, which is how we keep prices low. Shipping is free on items over $300 within the U.S., and our team can help with sizing and support.
Hurry to buy! Get your mini-split system with R-410A refrigerant (limited stock)
Important info
  • R-410A is being phased down in favor of newer refrigerants; inventory is limited.
  • Existing R-410A systems remain serviceable; parts and qualified service are widely available.
  • Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
  • We stock both R-410A and next-gen options—choose what fits your timeline and budget.

Cooper & Hunter SPH 24,000 BTU Indoor Multi Zone Universal Floor/Ceiling reviews

No reviews of the Cooper & Hunter SPH 24,000 BTU Indoor Multi Zone Universal Floor/Ceiling yet. Store rating: 4.5★ on Trustpilot (590 reviews of our service)

No reviews for this model yet.

Reviews of MiniSplitsForLess as a store on Trustpilot: ordering, shipping and support.

See all 590 reviews on Trustpilot ›

Reviews of MiniSplitsForLess as a store on Google: ordering, shipping and support.

Reviews of this model

Best brands with the best deals

Why buy this mini split from MiniSplitsForLess

  • Free Shipping on items over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
  • USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
  • Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
  • Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.

What Stands Out

Floor & Ceiling Flexibility

Mounts low on the wall or up near the ceiling — a versatile fit for rooms where a standard wall unit won't work, sized at 24000 BTU.

Inverter Efficiency — SEER2 23

A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 23 on 230V — steady comfort with noticeably lower energy bills.

Right-Sized Coverage

Heats & cools up to about 1,100 sq ft at average conditions (about 22 BTU per sq ft).

Universal Floor Ceiling

Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.

Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.

Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.

Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

White air conditioner with purple shield logo and text ’universal floor ceiling’ on a network background.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms
White air conditioning unit with black fan and copper tubing design.

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

White office cubicle partition with gray panels and black mesh chairs.

Main Features

Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

An outdoor air conditioning unit designed for high performance in extreme hot and cold weather.

Technical Specifications

Indoor Unit Specs

Indoor Unit Specs — CH-24MOLVWM-230VI
ModelCH-24MOLVWM-230VI
Unit Dimensions (WxDxH)42.64x9.61x13.23 in
Net/Gross Weight29.98/38.14 lb
Packing Dimensions (WxDxH)45.47x16.34x12.40 in
Power Supply208-230V, 1Ph, 60Hz
Maximum Fuse Size15 A
Min. Circuit Ampacity3 A
Copper Line Size (Liquid/Gas)3/8" - 5/8"
Noise Level (Hi/Med/Lo)46.5/44/35 dB
Airflow (Turbo/Hi/Mi/Lo)760.59/601.18/458.82/382.35 CFM
Dehumidification5.14 pt/h
Drain Pipe Diameter5/8"
ControllerRG10K-exclusive remote

System Specs

System Specs
Cooling Capacity 24,000 BTU
SEER2 23
Voltage 230V
Refrigerant Type R410A
Compressor Inverter
WiFi Not Included

Series Comparison Table

Technical specifications for every model in the series — this product is one of them.

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Cooling (Btu/h) 18,000 24,000 36,000 48,000 54,000
Rated Capacity Heating (Btu/h) 20,000 24,000 38,000 50,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 47/43.5/40.5 51/47/42 51.5/48.0/40.5 55/49.5/44.5 55/48/42
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
Indoor Packing (WxDxH) (inch) 45.08x29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature Cooling (°F) 62~90 62~90 62~90 62~90 62~90
Room Temperature Heating (°F) 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS REGULAR

Parameter ES-Series
CH-18MES-230V0 CH-28MES-230V0 CH-36MES-230V0 CH-48MES-230V0 CH-55MES-230V0
Power Supply (V, Ph, Hz) 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (Btu/h) 18,000(5,650~22,000) 28,000(9,838~30,438) 36,000(8,209~40,555) 48,000(19,000~50,000) 55,000(11,600-57,300)
Cooling Rated Current (A) 6.2 11 13.6 16.8 23.5
EER2 (Btu/h) 13.9 12.7 11.7 12.5 10.5
SEER2 (Btu/h) 22.9 24.6 23.9 23.4 21.3
Heating Rated Capacity (Btu/h) 19,000(5,050~24,400) 28,000(8,218-31,000) 37,000(8,008~44,632) 48,000(12,500~52,000) 55,000(12,500~63,000)
Heating Rated Current (A) 6.3 10.5 13 17.1 22.5
Heating at 47°F COP (W/W) 3.74 3.73 3.5 3.57 3.2
HSPF4 10.5 9.3 9.3 8.7 9.1
HSPF5 8 7.1 7.1 6.8 6.8
Heating at 5°F Rated Capacity (Btu/h) 12,600 19,000 25,200 33,000 32,200
Heating at 5°F COP (W/W) 2 2 1.8 1.8 1.8
Minimum Circuit Ampacity (Outdoor unit) (A) 18 24.5 25 40 40
Max. Fuse (Outdoor unit) (A) 25 30 40 60 60
Outdoor Air Flow (Max) (CFM) 1,765 2,129 2,147 4,500 4,500
Outdoor Noise Level (Sound Pressure) (dB(A)) 58 61 63 64 62
Dimension (WxDxH) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 40.55x17.24x29.53 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight 100/109 140/151 169/181 226/257 224/257
Refrigerant Type/Charged (oz) R410A/65.26 R410A/91.7 R410A/134.04 R410A/162 R410A/162
Refrigerant Precharge (ft) 49 74 98 123 123
Additional Charge for Each (oz/ft) 0.16 0.16 0.16 - *0.32 0.16 - *0.32 0.16 - *0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 2 x 1/4" 3 x 1/4" 4 x 1/4" 5 x 1/4" 5 x 1/4"
Refrigerant Piping Gas Side (inch) 2 x 3/8" 3 x 3/8" 3 x 3/8" + 1 x 1/2" 3 x 3/8" + 2 x 1/2" 3 x 3/8" + 2 x 1/2"
Max. Pipe Length (ft) 131 197 262 262 262
Max. Length for One Indoor Unit (ft) 82 98 115 115 115
Max. Height Difference in Level (ft) 49 49 49 49 49
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) 5~122 5~122 5-122 5-122 5~122
Ambient Temperature Heating (°F) -13~75 -13-75 -13~75 -13~75 -13~75
AHRI ✔ ✔
Energy Star ✔ ✔
NEEP ✔ ✔

INDOOR MODELS HYPER

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Rated Capacity Cooling (Btu/h) 17,000 24,000 36,000 48,000 55,000
Rated Capacity Heating (Btu/h) 18,000 25,000 39,000 51,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/ 1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 45.5/43/39 51/47.5/42 52.5/48.5/42.5 55/50/44 54/47/44
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
45.08×29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature (°F) Cooling: 62~90 Cooling: 62~90 Cooling: 62~90 Cooling: 62 ~ 90 Cooling: 62~ 90
Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS HYPER

Parameter CH-HPR19M-230V0 CH-HPR28M-230V0 CH-HPR36M-230V0 CH-HPR48M-230VO CH-HPR55M-230V0
Power Supply (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity (Btu/h) 19,000 (5,500~-25,000) 28,000(7,995-32,826) 36,000(17,900~42,000) 48,000 (19,300-51,000) 55,000(11,600~58,000)
Cooling Rated Current (A) 9.1 12.4 11.8 18 23.5
EER2 (Btu/h) 12.5 12.5 13.6 11.7 10.5
SEER2 (Btu/h) 22 23 22.2 21.8 22
Heating Rated Capacity (Btu/h) 20,000(8,100~29,700) 28,000(5,035~38,712) 36,500(12,500~49,000) 49,000(11,500~58,000) 55,000(33,000~63,000)
Heating Rated Current (A) 9.4 10.5 12.2 17.8 22.5
Heating at 47°F COP (W/W) 3.4 3.66 3.9 3.8 3.05
HSPF4 9.8 10.6 10.3 9.8 9.3
HSPF5 7.7 8.1 8.3 7.6 7.3
Heating at 5°F Rated Capacity (Btu/h) 19,000 24,000 36,000 48,000 37,800
Heating at 5°F COP (W/W) 1.96 1.75 1.9 2 1.8
Minimum Circuit Ampacity (Outdoor unit) (A) 20 25 40 42 40
Max. Fuse (Outdoor unit) (A) 25 40 60 50 60
Outdoor Air Flow (Max) (CFM) 2,129 2,147 4,500 4,500 4,500
Outdoor Noise Level (Sound Pressure) (dB(A)) 61 63 63 65 62
Dimension (WxDxH) (inch) 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight 138/149 168/179 223/254 238/270 233/266
Refrigerant Type/Charged (oz) R410A/91.7 R410A/134.04 R410A/162 R410A/162 R410A/162
Refrigerant Precharge (ft) 49 74 98 123 123
Additional Charge for Each (oz/ft) 0.16 0.16 - *0.32 0.16 - *0.32 0.16 - *0.32 0.16 -*0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side (inch) 2 x 1/4" 3 x 1/4" 4 x 1/4" 5 x 1/4" 5 x 1/4"
Refrigerant Piping Gas Side (inch) 2 x 3/8" 2 x 3/8" +1 x 1/2" 3 x 3/8" +1 x 1/2" 3 x 3/8" + 2 x 1/2" 3 x 3/8" +2 x 1/2"
Max. Pipe Length (ft) 131 197 262 262 262
Max. Length for One Indoor Unit (ft) 82 98 115 115 115
Max. Height Difference in Level (ft) 49 49 49 49 49.21
Max. Height Difference Between Indoor Units (ft) 33 33 33 33 33
Ambient Temperature Cooling (°F) 5~122 5~122 5~122 5~122 5~122
Ambient Temperature Heating (°F) -22~75 -22~75 -22~75 -22~75 -22~75

What’s Included

What’s Included
Indoor unitCH-24MSPHFC-230VI
Remote controllerRG10K-exclusive remote

Installation kit is not included in the selected option — pick 16ft, 25ft or 50ft above to add one.

Shipping & Returns

  • Free shipping on every item over $300.
  • Delivery estimate for your ZIP is shown in the buy box above.
  • Returns accepted per our policy — unopened units in original packaging.

Warranty

7-year compressor / 5-year parts

  • Limited manufacturer warranty on the compressor and sealed system components.
  • Your order number is the proof of purchase — keep it for any claim.

Multiple Control Methods

Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

What size mini split do I need for my home?

For optimal performance, the Cooper & Hunter SPH 24,000 BTU unit is designed to cover areas up to 1200 sq ft. Ensure you calculate your room size to confirm that this capacity aligns with your heating and cooling needs.

Can I install a mini split myself or do I need a professional?

While some homeowners may attempt a DIY installation, it is recommended to hire a professional for the Cooper & Hunter SPH 24,000 BTU unit to ensure proper setup and compliance with local codes. Incorrect installation can lead to inefficiencies or damage.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter SPH 24,000 BTU mini split comes pre-charged with R410A refrigerant for up to 25 ft of line set, making installation easier. However, adjustments may be necessary depending on your specific installation requirements.

What voltage does the Cooper & Hunter SPH mini split require?

The Cooper & Hunter SPH 24,000 BTU unit operates on a 230V electrical system, making it suitable for standard residential installations. Ensure your home's electrical system can support this voltage before purchasing.

What warranty does Cooper & Hunter offer on this mini split?

The Cooper & Hunter SPH 24,000 BTU mini split comes with a solid warranty: 5-year parts and 7-year compressor warranty, provided you register the unit within 30 days of installation. This warranty adds confidence in your investment.

What SEER rating do I need for energy efficiency?

The Cooper & Hunter SPH 24,000 BTU unit boasts a SEER rating of 23.0, which is highly efficient and exceeds the minimum requirements for energy savings. A higher SEER rating indicates better efficiency, potentially lowering your energy costs.