Cooper & Hunter SPH 24,000 BTU Indoor Universal Floor/Ceiling, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump | No Kit






Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Type | |
| Freon | |
| Compressor |
⛔ Wait! This is an Individual Component To build a working system, this unit must match your other equipment in two ways:
- Same Brand Only: Only pair with other same Brand and Series.
- Same Refrigerant: Both units must use the exact same gas type (R454B, R32, or R410A).
Mixing different brands or refrigerant types will cause the system to fail and void your warranty.
Pickup currently unavailable at 3550 Northwest 113th Court
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Universal Floor Ceiling
Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.
Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.
Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.
Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

Technical Specifications
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W | |
|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | |
| Rated Capacity Cooling (Btu/h) | 18,000 | 24,000 | 36,000 | 48,000 | 54,000 | |
| Rated Capacity Heating (Btu/h) | 20,000 | 24,000 | 38,000 | 50,000 | 60,000 | |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 | |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/1,118/1,000 | 1,430/1,384/1,029/795 | |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 47/43.5/40.5 | 51/47/42 | 51.5/48.0/40.5 | 55/49.5/44.5 | 55/48/42 | |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 | |
| Indoor Packing (WxDxH) (inch) | 45.08x29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 | |
| Room Temperature Cooling (°F) | 62~90 | 62~90 | 62~90 | 62~90 | 62~90 | |
| Room Temperature Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" | |
OUTDOOR MODELS REGULAR
| Parameter | ES-Series | ||||
|---|---|---|---|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 | CH-36MES-230V0 | CH-48MES-230V0 | CH-55MES-230V0 | |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | ||||
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) | 28,000(9,838~30,438) | 36,000(8,209~40,555) | 48,000(19,000~50,000) | 55,000(11,600-57,300) |
| Cooling Rated Current (A) | 6.2 | 11 | 13.6 | 16.8 | 23.5 |
| EER2 (Btu/h) | 13.9 | 12.7 | 11.7 | 12.5 | 10.5 |
| SEER2 (Btu/h) | 22.9 | 24.6 | 23.9 | 23.4 | 21.3 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) | 28,000(8,218-31,000) | 37,000(8,008~44,632) | 48,000(12,500~52,000) | 55,000(12,500~63,000) |
| Heating Rated Current (A) | 6.3 | 10.5 | 13 | 17.1 | 22.5 |
| Heating at 47°F COP (W/W) | 3.74 | 3.73 | 3.5 | 3.57 | 3.2 |
| HSPF4 | 10.5 | 9.3 | 9.3 | 8.7 | 9.1 |
| HSPF5 | 8 | 7.1 | 7.1 | 6.8 | 6.8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 | 19,000 | 25,200 | 33,000 | 32,200 |
| Heating at 5°F COP (W/W) | 2 | 2 | 1.8 | 1.8 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 | 24.5 | 25 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 30 | 40 | 60 | 60 |
| Outdoor Air Flow (Max) (CFM) | 1,765 | 2,129 | 2,147 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 | 61 | 63 | 64 | 62 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 100/109 | 140/151 | 169/181 | 226/257 | 224/257 |
| Refrigerant Type/Charged (oz) | R410A/65.26 | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5-122 | 5-122 | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13-75 | -13~75 | -13~75 | -13~75 |
| AHRI | ✔ | ✔ | |||
| Energy Star | ✔ | ✔ | |||
| NEEP | ✔ | ✔ | |||
INDOOR MODELS HYPER
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity Cooling (Btu/h) | 17,000 | 24,000 | 36,000 | 48,000 | 55,000 |
| Rated Capacity Heating (Btu/h) | 18,000 | 25,000 | 39,000 | 51,000 | 60,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/ 1,118/1,000 | 1,430/1,384/1,029/795 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 45.5/43/39 | 51/47.5/42 | 52.5/48.5/42.5 | 55/50/44 | 54/47/44 |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 |
| 45.08×29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 |
| Room Temperature (°F) | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62 ~ 90 | Cooling: 62~ 90 |
| Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" |
OUTDOOR MODELS HYPER
| Parameter | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my home?
For optimal performance, the Cooper & Hunter SPH 24,000 BTU unit is designed to cover areas up to 1200 sq ft. Ensure you calculate your room size to confirm that this capacity aligns with your heating and cooling needs.
Can I install a mini split myself or do I need a professional?
While some homeowners may attempt a DIY installation, it is recommended to hire a professional for the Cooper & Hunter SPH 24,000 BTU unit to ensure proper setup and compliance with local codes. Incorrect installation can lead to inefficiencies or damage.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter SPH 24,000 BTU mini split comes pre-charged with R410A refrigerant for up to 25 ft of line set, making installation easier. However, adjustments may be necessary depending on your specific installation requirements.
What voltage does the Cooper & Hunter SPH mini split require?
The Cooper & Hunter SPH 24,000 BTU unit operates on a 230V electrical system, making it suitable for standard residential installations. Ensure your home's electrical system can support this voltage before purchasing.
What warranty does Cooper & Hunter offer on this mini split?
The Cooper & Hunter SPH 24,000 BTU mini split comes with a solid warranty: 5-year parts and 7-year compressor warranty, provided you register the unit within 30 days of installation. This warranty adds confidence in your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter SPH 24,000 BTU unit boasts a SEER rating of 23.0, which is highly efficient and exceeds the minimum requirements for energy savings. A higher SEER rating indicates better efficiency, potentially lowering your energy costs.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control
Architectural Integration Concealed Ducted Mini Splits: The Architect's Standard for Invisible Climate Control I still remember a brutal custom build...
Why Buy from MiniSplitsForLess? Wholesale Prices and Top Deals
Behind the Pricing Why Buy from MiniSplitsForLess? Real Wholesale Pricing Without the Retail Games You’re about to click "Buy" on...
Mini Splits for Older Homes Without Ductwork: The Complete 2026 Retrofit Guide
The 2026 Retrofit Guide Mini Splits for Older Homes Without Ductwork Look, I love old homes. I’ve spent more weekends...