Cooper & Hunter OLIVIA 36,000 BTU Outdoor Condenser, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump






Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Wall Mount
The Cooper&Hunter Olivia Unit mini splits AC blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit mini splits AC is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter mini splits AC products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s mini split AC Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units mini split AC feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.
All Accessories Included
With your purchase mini split AC, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.
Technical Specifications
INDOOR MODELS HYPER
| Indoor Model | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS
| Outdoor Regular | CH-ES06-115V0 | CH-ES09-115VO | CH-ES12-115VO | CH-ES09-230V0 | CH-ES12-230V0 | CH-ES18-230V0 | CH-ES24-230V0 |
|---|---|---|---|---|---|---|---|
| Power Supply | 115V, 1Ph, 60Hz | 115V, 1Ph, 60Hz | 115V, 1Ph, 60Hz | 208/230V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 103.5~126.5 | 103.5~126.5 | 103.5~126.5 | 187~253 | 187~253 | 187~253 | 187~253 |
| Rated Capacity (range) Cooling (Btu/h) | 6,300 (3,900~13,200) | 9,000 (3,900~13,200) | 12,000 (3,900~13,800) | 9,000 (2,560~11,900) | 12,000 (3,080~13,300) | 18,000 (7,320~19,500) | 24,000 (9,200~25,000) |
| Rated Current Cooling (A) | 3.8 | 6.5 | 8.7 | 3.48 | 4.5 | 6.31 | 10.35 |
| EER2 (Btu/h) | 13.6 | 13.8 | 12.5 | 14.7 | 13 | 13.5 | 13 |
| SEER2 (Btu/h) | 23 | 23 | 22.7 | 24 | 23.1 | 24 | 21 |
| Rated Capacity (range) Heating (Btu/h) | 7,000 (5,000~12,680) | 10,000 (5,000~12,680) | 12,000 (5,000~12,680) | 10,000 (3,480~13,000) | 12,000 (4,260~13,560) | 18,000 (6,620~21,200) | 26,000 (10,350~26,410) |
| Rated current Heating (A) | 4.8 | 6.7 | 8.7 | 3.48 | 4.5 | 6.31 | 10.35 |
| Heating at 47°F COP (W/W) | 3.91 | 3.91 | 3.52 | 3.66 | 3.4 | 3.74 | 3.15 |
| HSPF4 | 9.8 | 9.8 | 10.4 | 11.6 | 10.8 | 10.5 | 8.5 |
| HSPF5 | 7.6 | 7.6 | 7.6 | 8.8 | 8 | 7.9 | 6.3 |
| Minimum Circuit Ampacity (A) | 19 | 19 | 19 | 13 | 13 | 19 | 23 |
| Max.Fuse (A) | 25 | 25 | 25 | 15 | 15 | 30 | 30 |
| Outdoor Air Flow (Max.) (CFM) | 794 | 794 | 794 | 1,294 | 1,294 | 2,058 | 2,235 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 54 | 54 | 54 | 53 | 54.5 | 53.8 | 62 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 35.04x15.48x28.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 39.17x15.67x29.13 | 42.91x19.69x34.64 |
| Net/Gross Weight (lbs.) | 66.80/72.31 | 66.80/72.31 | 66.80/72.31 | 63.71/69.00 | 63.71/69.00 | 94.36/100.97 | 124.78/134.92 |
| Refrigerant Type / Charge | R410A/38.81 | R410A/38.81 | R410A/38.81 | R410A/38.1 | R410A/38.1 | R410A/56.44 | R410A/82.89 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge For Each ft. (oz/ft.) | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
| Max. Pipe Length (ft.) | 82 | 82 | 82 | 82 | 82 | 98 | 164 |
| Max. Difference In Level (ft.) | 32.8 | 32.8 | 32.8 | 32.8 | 32.8 | 66 | 82 |
| Ambient Temp. Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temp. Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certifications UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Certifications AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Certifications Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Outdoor Hyper | CH-HPR06F9-230VO | CH-HPR09-230V0 | CH-HPR12-230V0 | CH-HPR18-230V0 | CH-HPR24-230V0 |
|---|---|---|---|---|---|
| Power Supply - Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Power Supply - Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling - Rated Capacity (range) (Btu/h) | 6,000 (2,500-11,800) | 9,000 (3,700~13,300) | 12,000 (3,700~13,300) | 18,000 (8,400~20,200) | 23,000 (4,650~26,600) |
| Cooling - Rated Current (A) | 4.75 | 4 | 4.25 | 9.2 | 11.38 |
| Cooling - EER2 (Btu/h) | 15 | 15.8 | 13 | 13 | 12.5 |
| Cooling - SEER2 (Btu/h) | 23.5 | 26.4 | 23.1 | 22 | 22.3 |
| Heating at 47°F - Rated Capacity (range) (Btu/h) | 7,000 (3,400-11,230) | 12,000 (5,100~14,300) | 12,000 (5,100~14,300) | 18,000 (6,000~23,000) | 26,000 (9.550~27,000) |
| Heating at 47°F - Rated current (A) | 3.76 | 4 | 4.25 | 9.2 | 11.38 |
| Heating at 47°F - COP (W/W) | 3.76 | 3.9 | 3.6 | 3.35 | 3 |
| Heating at 47°F - HSPF4 | 12 | 11.6 | 10.5 | 10.6 | 10.3 |
| Heating at 47°F - HSPF5 | 10 | 8.5 | 8 | 7.9 | 7.7 |
| Minimum Circuit Ampacity (A) | 13 | 15 | 15 | 20 | 25 |
| Max.Fuse (A) | 15 | 15 | 15 | 25 | 35 |
| Outdoor Air Flow (Max.) (CFM) | 1,294 | 1,324 | 1,324 | 1,765 | 2,235 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 53.5 | 55.5 | 56 | 58 | 62.5 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 31.69x12.99x21.81 | 31.69x12.99x21.81 | 35.04x13.46x26.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 36.02x14.57x24.21 | 36.02x14.57x24.21 | 39.17x15.67x29.13 | 42.91x19.69x34.84 |
| Net/Gross Weight (lbs) | 63.71/69 | 74.07/80.25 | 73.63/79.37 | 100.97/108.03 | 134.48/144.40 |
| Refrigerant Type / Charge (oz.) | R410A/38.1 | R410A/41.62 | R410A/41.62 | R410A/65.2 | R410A/91.7 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping - Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
| Refrigerant Piping - Max. Pipe Length (ft.) | 82 | 82 | 82 | 98 | 164 |
| Refrigerant Piping - Max. Difference in Level (ft.) | 32.8 | 32.8 | 32.8 | 66 | 82 |
| Ambient Temperature - Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Ambient Temperature - Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Certifications - UL | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certifications - AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certifications - Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit mini split AC can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my home?
To determine the appropriate size mini split for your space, consider that the Cooper & Hunter SPH 36,000 BTU model can effectively cover areas up to 1,500 sq ft. Ensure that your room's size aligns with this coverage to optimize heating and cooling efficiency.
Can I install a mini split myself?
While DIY installation of the Cooper & Hunter SPH 36,000 BTU mini split is possible, professional installation is recommended for optimal performance. The complexity of the system, including proper refrigerant handling and electrical connections, can affect efficiency and warranty coverage.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter SPH 36,000 BTU mini split comes pre-charged with R410A refrigerant for installations with up to 25 ft of line set. This feature simplifies the installation process, allowing for a quicker setup.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter SPH 36,000 BTU mini split operates on a 230V power supply, making it compatible with most residential electrical systems in North America. Ensure your electrical setup meets this requirement for proper operation.
What warranty does the Cooper & Hunter SPH offer?
The Cooper & Hunter SPH 36,000 BTU mini split comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of installation. This warranty offers peace of mind for your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter SPH 36,000 BTU model has a SEER rating of 24.0, which is highly efficient and exceeds the minimum requirements for most regions. A higher SEER rating means lower energy costs and better performance, making this unit an excellent choice for energy-conscious consumers.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026
2026 Climate Solution Guide Mini Split AC and Heat Systems: Your All-in-One Climate Solution for 2026 Most homeowners know...
Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins?
Buyer's Guide • Cooling Systems Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins? You measured the...
How Much Square Footage Can a 24,000 BTU Mini Split Cool?
Complete Sizing Guide How Much Square Footage Can a 24,000 BTU Mini Split Cool? You’ve measured your great room. You’ve...