Cooper & Hunter 24,000 BTU Single Zone Universal Floor/Ceiling, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump | No Kit










Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Why buy this mini split from MiniSplitsForLess
- Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Floor & Ceiling Flexibility
Mounts low on the wall or up near the ceiling — a versatile fit for rooms where a standard wall unit won't work, sized at 24000 BTU.
Inverter Efficiency — SEER2 21.1
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 21.1 on 230V — steady comfort with noticeably lower energy bills.
Right-Sized Coverage
Engineered to heat & cool up to 800–1200 sq ft — matched capacity so you never over- or under-size the space.
Universal Floor Ceiling
Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.
Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.
Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.
Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W | |
|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | |
| Rated Capacity Cooling (Btu/h) | 18,000 | 24,000 | 36,000 | 48,000 | 54,000 | |
| Rated Capacity Heating (Btu/h) | 20,000 | 24,000 | 38,000 | 50,000 | 60,000 | |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 | |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/1,118/1,000 | 1,430/1,384/1,029/795 | |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 47/43.5/40.5 | 51/47/42 | 51.5/48.0/40.5 | 55/49.5/44.5 | 55/48/42 | |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 | |
| Indoor Packing (WxDxH) (inch) | 45.08x29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 | |
| Room Temperature Cooling (°F) | 62~90 | 62~90 | 62~90 | 62~90 | 62~90 | |
| Room Temperature Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" | |
OUTDOOR MODELS REGULAR
| Outdoor Model | CH-ES18-230V0 | CH-ES24-230V0 | CH-N36LCU-230V0 | CH-N48LCU-230V0 | CH-N60LCU-230V0 | |
|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | |
| Power Supply Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | |
| Cooling Rated Capacity Range (Btu/h) | 6,200~18,000 | 7,700~25,500 | 11,476~36,000 | 15,861~48,000 | 15,000~54,000 | |
| Cooling Rated Current (A) | 6.29 | 8.78 | 19.09 | 23.6 | 24.10 | |
| Cooling EER2 (Btu/h) | 12.5 | 12.5 | 8.5 | 9.3 | 9.8 | |
| Cooling SEER2 (Btu/h) | 23 | 21.2 | 19 | 18.9 | 19.8 | |
| Heating at 47°F Rated Capacity Range (Btu/h) | 8,100~20,000 | 11,600~30,900 | 11,467~38,000 | 12,159~50,000 | 17,000~60,000 | |
| Heating at 47°F Rated current (A) | 8.51 | 8.77 | 18.04 | 25.5 | 25.5 | |
| Heating at 47°F COP (W/W) | 2.92 | 3.66 | 2.68 | 2.5 | 3.03 | |
| Heating at 47°F HSPF4 (아) | 10 | 10.3 | 9 | 10 | 9 | |
| Heating at 47°F HSPF5 | 7.7 | 7.8 | 7 | 7.5 | 7 | |
| Minimum Circuit Ampacity (A) | 19 | 23 | 30 | 36.5 | 39 | |
| Max.Fuse (Outdoor Unit) (A) | 30 | 30 | 45 | 50 | 50 | |
| Outdoor Air Flow (Max.) (CFM) | 2,059 | 2,235 | 3,000 | 4,500 | 2,647 | |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 60 | 61 | 65 | 63.5 | 64 | |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | |
| Packing (WxDxH) (inch) | 39.17x15.67x29.13 | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | |
| Net/Gross Weight (lbs.) | 94.36/100.97 | 124.78/134.92 | 155.42/166.23 | 219.14/249.12 | 217.15/248.24 | |
| Refrigerant Type / Charge (oz.) | R410A/56.44 | R410A/82.89 | R410A/113 | R410A/159 | R410A/169.3 | |
| Refrigerant Precharge Length (ft) | 25 | 25 | 25 | 25 | 25 | |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 | |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" | |
| Max. Pipe Length (ft.) | 98.42 | 164.04 | 213.25 | 213.25 | 213.25 | |
| Max. Difference in Level (ft.) | 65.62 | 82.02 | 98.42 | 98.42 | 98.42 | |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | 5~122 | 5~122 | 5~122 | |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | 5~75 | 5~75 | 5~75 | |
INDOOR MODELS HYPER
| Indoor Model | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity Cooling (Btu/h) | 17,000 | 24,000 | 36,000 | 48,000 | 55,000 |
| Rated Capacity Heating (Btu/h) | 18,000 | 25,000 | 39,000 | 51,000 | 60,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/ 1,118/1,000 | 1,430/1,384/1,029/795 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 45.5/43/39 | 51/47.5/42 | 52.5/48.5/42.5 | 55/50/44 | 54/47/44 |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 |
| 45.08×29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 |
| Room Temperature (°F) | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62 ~ 90 | Cooling: 62~ 90 |
| Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" |
OUTDOOR MODELS HYPER
| Outdoor Model | CH-HPR18-230V0 | CH-HPR24-230VO | CH-NHPR36LCU-230V0 | CH-NHPR48LCU-230V0 | CH-NHPR60LCU-230V0 |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Power Supply Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling - Rated Capacity Range (Btu/h) | 7,800 ~ 19,900 | 5,400 ~ 26,800 | 7,780~42,100 | 2,150~48,000 | 20,000~55,000 |
| Cooling - Rated Current (A) | 8.80 | 9.55 | 17.8 | 24.86 | 27 |
| Cooling - EER2 (Btu/h) | 12.5 | 11.7 | 8.8 | 8.2 | 9 |
| Cooling SEER2 (Btu/h) | 20.5 | 20.5 | 17.6 | 17 | 17.3 |
| Heating at 47°F - Rated Capacity Range (Btu/h) | 8,600~21,500 | 12,500~30,500 | 11,500~45,700 | 11,800~56,300 | 10,200~62,000 |
| Heating at 47°F - Rated Current (A) | 10.9 | 9.15 | 19 | 20.6 | 26 |
| Heating at 47°F - COP (W/W) | 3.01 | 3.56 | 2.69 | 2.9 | 2.98 |
| Heating at 47°F - HSPF4 | 9.8 | 11 | 10 | 9.8 | 10.2 |
| Heating at 47°F - HSPF5 | 7.5 | 9 | 8.2 | 7.5 | 8.4 |
| Minimum Circuit Ampacity (A) | 20 | 25 | 40 | 40 | 44 |
| Max.Fuse (Outdoor Unit) (A) | 25 | 35 | 50 | 50 | 60 |
| Outdoor Air Flow (Max.) (CFM) | 1,765 | 2,235 | 4,500 | 4,500 | 4,235 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59 | 62.5 | 63 | 65 | 61 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 39.17x15.67x29.13 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs.) | 100.97/108.03 | 134.48/144.40 | 220.24/248.02 | 227.07/255.73 | 240.74/271.61 |
| Refrigerant Type / Charge (oz.) | R410A / 65.26 | R410A / 91.71 | R410A / 148.4 | R410A / 148 | R410A / 169 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8" /5/8" | 3/8" /7/8" |
| Max. Pipe Length (ft.) | 98.42 | 164.04 | 213.25 | 213.25 | 213.25 |
| Max. Difference in Level (ft.) | 65.62 | 82.02 | 98.42 | 98.42 | 98.42 |
| Cooling Ambient Temperature Range (°F) | -22~122 | -22~122 | 5~122 | 5~122 | 5~122 |
| Heating Ambient Temperature Range (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Multiple Control Methods
Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my space?
For coverage of up to 1200 sq ft, the Cooper & Hunter 24,000 BTU mini split is ideal for larger rooms or open-concept areas. Ensure your space's heating and cooling requirements align with this capacity for optimal performance.
Can I install a mini split myself?
While the Cooper & Hunter 24,000 BTU unit can be installed by a DIY enthusiast, professional installation is recommended for best results. The complexity of the 230V electrical connection and refrigerant handling may require technical expertise.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, allowing for easier installation. This feature ensures the system is ready to operate upon installation within the specified range.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter 24,000 BTU mini split operates on a 230V electrical supply, which is standard for many residential applications. Ensure your electrical system can support this voltage for safe and efficient operation.
What warranty does Cooper & Hunter offer for this model?
The Cooper & Hunter 24,000 BTU mini split comes with a solid warranty: a 5-year parts and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This warranty gives you peace of mind regarding your investment.
What is the SEER rating of the Cooper & Hunter mini split and why is it important?
The Cooper & Hunter 24,000 BTU mini split features an impressive SEER rating of 21.1, indicating high energy efficiency. A higher SEER rating means lower energy bills and reduced environmental impact, making it a smart choice for both cooling and heating needs.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
2 Ton Mini Split Performance: Square Footage and Best Models
High Capacity Cooling 2 Ton Mini Split Performance: Square Footage and Best Models Let's talk about cooling big spaces. If...
Upgrading From a Legacy Wall AC to a Mini Split
Upgrade Your Comfort Upgrading From a Legacy Wall AC to a Mini Split Let's be honest. That metal box shoved...
3 Ton Mini Split Heating and Cooling Capacities Explained
System Sizing Masterclass 3 Ton Mini Split Heating and Cooling Capacities Explained Last week, I got called out to a...