Cooper & Hunter 3 Zone 28,000 BTU Ducted Mini Split AC Concealed Duct 9k+9k+12k










Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Concealed Duct
Cooper&Hunter's Slim Duct Units offer a discreet and efficient climate control solution for residential and commercial spaces. With capacities ranging from 9,000 to 60,000 BTU and SEER2 ratings up to 20.2, these units ensure energy-efficient performance.
Their slim design allows for concealed installation in ceilings or walls, maintaining a sleek interior. Equipped with advanced inverter technology, quiet operation, and optional Wi-Fi control, Slim Duct Units provide reliable, customizable comfort while blending seamlessly into any space.
Perfect for single or multi-zone systems, they deliver powerful performance with minimal ductwork.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Slim Duct Units feature inverter technology, ultra-quiet operation, flexible ducting, and optional Wi-Fi control, their slim design allows concealed installation, ensuring powerful performance, energy efficiency, and a seamless fit for any space.

All Accessories Included
With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor
| Indoor Model | CH-RS06MDT-MS CH-RS06-12MDT-MS (Dip Switch 6) |
CH-RS09MDT-MS CH-RS06-12MDT-MS (Dip Switch 9) |
CH-RS12MDT-MS CH-RS06-12MDT-MS (Dip Switch 12) |
CH-RS18MDT-MS | CH-RS24MDT-HS | CH-RS36CLCDT-HS | CH-RS48CLCDT-HS | CH-RS60CLCDT-HS |
|---|---|---|---|---|---|---|---|---|
| Power Supply | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity | 6,500/8,000 | 9,000/10,000 | 12,000/12,500 | 17,000/19,000 | 24,000/26,000 | 36,000/42,000 | 48,000/52,000 | 55,000/60,000 |
| Minimum Circuit Ampacity (MCA) | 3 | 3 | 3 | 3 | 3 | 4 | 5 | 5 |
| Max. Fuse | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 323.7/264.9/206.0/147.2/117.7 | 323.7/264.9/206.0/147.2/117.7 | 400.2/323.7/264.9/176.6/117.7 | 600.4/559.2/500.3/441.4/NA | 853.5/706.3/618.0/500.3/NA | 1236.1/1059.5/941.8/766.5/NA | 1648.1/1471.5/1294.9/1059.5/NA | 2001.2/1706.9/1412.6/1118.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | NA/32.5/30.5/29.5/22 | NA/32.5/31/29.5/23 | NA/36/34.5/32.5/25.5 | NA/40/39/38/32 | NA/40/37/35/29.5 | NA/45/40/34/31 | NA/51/46/42/40 | NA/52/48/42/41 |
| Dimension (WxDxH) inch | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 34.65 x 26.54 x 8.27 | 39.37 x 29.53 x 9.65 | 47.24 x 29.53 x 11.81 | 47.24 x 29.53 x 11.81 | 55.12 x 31.50 x 14.96 |
| Packing (WxDxH) inch | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 42.13 x 28.54 x 11.02 | 48.23 x 33.86 x 11.97 | 56.10 x 33.86 x 14.13 | 56.10 x 33.86 x 14.13 | 62.99 x 36.02 x 17.52 |
| Net/Gross Weight lbs. | 39.46/46.74 | 39.46/46.74 | 39.46/46.74 | 54.45/66.14 | 80.47/91.93 | 106.26/120.37 | 111.33/124.78 | 161.38/178.13 |
| Room Temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room Temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4"/3/8" | 1/4"/3/8" | 1/4"/3/8" | 1/4"/1/2" | 3/8"/5/8" | 3/8"/3/4" | 3/8"/3/4" | 3/8"/3/4" |
Outdoor Regular
| Specification | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 6 | 9.2 | 13.5 | 16.6 | 26.2 |
| EER2 | 14 | 13 | 12 | 12.5 | 10 |
| SEER2 | 25.1 | 25 | 24 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 | 20,000~60,000 |
| Heating Rated Current (A) | 6.8 | 9.2 | 14 | 16.3 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.5 | 3.8 | 3.7 |
| HSPF4 | 9.8 | 9.5 | 9.5 | 10.3 | 9.5 |
| HSPF5 | 7.8 | 7 | 7 | 8 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 13,500 | 19,000 | 26,000 | 36,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 16 | 23 | 30.5 | 40 | 40 |
| Max. Fuse (Outdoor unit) (A) | 20 | 25 | 35 | 45 | 45 |
| Outdoor Air Flow (Max) (CFM) | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 59.5 | 61 | 64.5 | 63 | 65 |
| Dimension (W×D×H) (inch) | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 | R454B/151.68 |
| Refrigerant Precharge (ft) | 75 | 100 | 125 | 150 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Slim Duct Unit can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
How many rooms can the Cooper & Hunter 3 Zone 28,000 BTU Mini Split cool?
The Cooper & Hunter 3 Zone 28,000 BTU Mini Split can effectively cool up to three rooms, with individual capacities of 9,000 BTU for two zones and 12,000 BTU for the third zone. This allows for targeted cooling based on the specific needs of each room.
Can I mix BTU sizes in a multi-zone mini split like the Cooper & Hunter 28k?
Yes, you can mix BTU sizes in the Cooper & Hunter 28,000 BTU Mini Split system, as long as the total does not exceed the system's capacity. This allows for customization based on room sizes, such as pairing 9,000 BTU and 12,000 BTU units for optimal efficiency.
Do all zones in the Cooper & Hunter Mini Split run simultaneously?
No, the zones in the Cooper & Hunter Mini Split can operate independently, allowing you to cool or heat each zone based on demand. This feature enhances energy efficiency compared to running multiple single-zone units.
What is the warranty on the Cooper & Hunter Mini Split system?
The Cooper & Hunter Mini Split comes with a 5-year parts warranty and a 7-year compressor warranty, provided registration is completed within 30 days of installation. This ensures you are covered for any manufacturing defects during the specified periods.
Does the Cooper & Hunter Mini Split come pre-charged with refrigerant?
Yes, the Cooper & Hunter 3 Zone Mini Split is pre-charged with R454B refrigerant for up to 25 ft of line set, making installation more straightforward. However, if your line set exceeds this length, additional refrigerant will be required.
What is the efficiency rating of the Cooper & Hunter Mini Split system?
The Cooper & Hunter 3 Zone Mini Split boasts a SEER rating of 21.0, indicating high energy efficiency. This rating is beneficial for reducing energy costs compared to older systems and multiple single-zone units.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
The Worst Time to Buy a Mini Split? Right After the First Real Heat Wave
Procurement Strategy • HVAC Installation The First Hot Week of Summer? Too Late to Shop for a Mini Split Waiting...
Mini Split vs Central Air in 2026: Costs, Comfort & Energy Savings Compared
HVAC Engineering • 2026 Report • Thermal Dynamics The 2026 Thermal Evolution: Embracing the Future MiniSplitsForLess Insights 6 Min Read...
Best Ductless Mini Splits in 2026: Buyer’s guide, Tips & Top picks
Engineering Excellence • 2026 Edition • USA The Definitive Mini Split Master Class for 2026 You are standing at a...


































