Cooper & Hunter Olivia 30,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump | No Kit

Cooper & Hunter

CH-REL30-230VO33OLV
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 18
WiFi Included
Zone Single Zone
Type Wall Mount
Freon R454B
Compressor Inverter
$2,312.64
Shipping Policy calculated at checkout.
*Installation Kit Option* =: NO INSTALLATION KIT

Pickup available at 3550 Northwest 113th Court

Usually ready in 2-4 days

FREE Armbridge Accessory With This Purchase

Choose one below — it will be added to your cart for free

Select your free accessory:

FREE
ARMBRIDGE AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base with Built-In Leveler
AB-RF Rubber Feet Mounting Set Heavy-Duty Adjustable Base...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Zinc,...
FREE
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Foldable 304 Stainless Steel, Vibration-Absorbing (Up to 550 lbs Each)
Mini Split Wall Mounting Bracket High Load Capacity Folda...
FREE
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 9,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity
Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets ...
FREE
ARMBRIDGE 18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, Anti-Slip Foundation for HVAC Systems and Outdoor Equipment
18"x38"x3" Ribbed Plastic Condenser Pad Shock-Absorbing, ...
Free gift added to your cart!
*Installation Kit Option* =
Discount Banner
TrustScore 4.8

Olivia Wall Mount

The Cooper&Hunter Olivia Unit  mini split AC blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.

Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.

Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

White air conditioner with purple shield logo and ’olivia’ text.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms
White air conditioning unit with black fan and copper tubing design.

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter mini split AC for cutting-edge HVAC solutions that deliver optimal performance and reliability.

White leather sectional sofa with modern design and clean lines.

Main Features

Cooper&Hunter's Olivia Units mini split AC feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included

With your purchase mini split AC, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

Indoor and Outdoor Hyper

Indoor Model CH-RM06MOLVWM-115VI CH-RM09MOLVWM-230VI CH-RM12MOLVWM-230VI CH-RM18MOLVWM-230VI CH-RM24MOLVWM-230VI CH-RM33HEMLVWM-230VI
Power Supply Rated 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Btu/h 6,000 9,000 12,000 18,000 23,000 33,000
Minimum Circuit Ampacity (MCA) A 3 3 3 3 3 3
Max. Fuse A 3 3 3 3 3 3
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM 294.3/225.4/176.8/141.3/NA 382.6/293.1/194.2/153.0/NA 382.6/293.1/194.2/153.0/NA 759.3/530.4/419.1/382.6/NA 759.3/586.5/419.1/382.6/NA 829.6/716.6/592.7/447.3/NA
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) 42.0/37.0/32.0/24.0/NA 42.0/37.0/32.0/24.0/NA 43.0/37.0/32.0/24.0/NA 52.5/44.0/40.5/35.2/25.0 54.5/49.0/45.3/41.3/27.0 56.0/49.5/45.3/41.3/27.0
Dimension (WxDxH) inch 28.7x7.87x11.81 31.5x7.87x11.61 31.5x7.87x11.61 45.47x12.01x16.14 45.47x12.01x16.14 52.76x15.16x17.72
Packing (WxDxH) inch 31.10x10.63x14.76 34.45x11.22x14.96 34.45x11.22x14.96 45.47x12.01x16.14 45.47x12.01x16.14 52.76x15.16x17.72
Net/Gross Weight lbs. 17.64/21.35 18.64/22.05 18.64/22.05 45.47/21.06 45.47/21.06 67.16/17.72
Room temperature Cooling °F 60~90 60~90 60~90 60~90 60~90 60~90
Room temperature Heating °F 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 3/8" / 3/4"
Outdoor Model CH-RHP06F9-230VO CH-RHP09-230VO CH-RHP12-230VO CH-RHP18-230VO CH-RHP24-230VO CH-RHP33-230VO
Power Supply Rated V, Ph, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range V 187-253 187-253 187-253 187-253 187-253 187-253
Rated Capacity Range Btu/h 2,500~11,500 3,000~13,500 3,600~13,500 8,400~20,200 16,240~24,800 15,000~35,000
Cooling EER2 Btu/h 16.0 16.0 16.0 12.0 11.7 11.7
SEER2 Btu/h 20.0 20.0 20.0 18.0 17.0 17.0
Rated current A 4.0 4.3 4.3 9.5 11.2 14.1
Heating at 47°F COP W/W 3.63 3.63 3.63 3.00 3.22 3.22
HSPF4 14.6 12.5 12.5 10.3 10.5 10.5
HSPF5 12.5 10.3 10.3 8.3 8.3 8.3
Heating at 17°F (AHRI) Rated capacity Btu/h 8,600 12,800 12,800 19,800 24,400 30,200
Minimum Circuit Ampacity A 12 15 15 19 24.9 35
Max.Fuse (Outdoor Unit) A 15 15 15 25 30 40
Outdoor Air Flow (Max.) CFM 1,235.3 1,470.6 1,470.6 1,764.7 2,235.3 2,235.3
Outdoor Noise Level (Sound Pressure) dB(A) 53.0 53.0 53.0 61.0 63.0 63.5
Dimension (WxDxH) inch 30.1x21.9x21.85 31.68x21.9x21.81 31.68x21.9x21.81 35.04x13.46x29.13 42.91x18.9x34.84 37.44x19.09x34.84
Packing (WxDxH) inch 34.92x13.27x24.02 36.02x14.75x24.21 36.02x14.75x24.21 39.17x15.67x29.13 42.91x19.09x34.84 42.91x19.09x34.84
Net/Gross Weight lbs. 62.17/87.68 72.75/78.70 72.75/78.70 99.87/107.80 139.20/141.31 156.87/197.99
Refrigerant Type / Charge oz. R454B/25.24 R454B/25.27 R454B/25.27 R454B/35.38 R454B/43.44 R454B/87.13
Refrigerant Precharge Length # 25 25 25 25 25 25
Additional Charge for Each ft. oz/ft 0.16 0.16 0.16 0.16 0.16 0.32
Design Pressure PSIG 550/340 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 3/8" / 5/8" 3/8" / 3/4"
Max. Pipe Length ft. 82 82 82 82 164 164
Max. Difference in Level ft. 49.2 49.2 49.2 65.6 82 82
Ambient Temperature Cooling °F -22~122 -22~122 -22~122 -22~122 -22~122 -22~122
Heating °F -22~75 -22~75 -22~75 -22~75 -22~75 -22~75
UL
AHRI
Energy Star
NEEP

Indoor and Outdoor Regular

Indoor Model CH-R060LVWM-115VI CH-R09OLVWM-115VI CH-R120LVWM-115VI CH-RO9MOLVWM-230VI CH-R12MOLVWM-230VI CH-R18MOLVWM-230VI CH-R24MOLVWM-230VI CH-R30MELVWM-230VI CH-R36MELVWM-230VI
Power Supply Rated 115V, 1, 60 115V, 1, 60 115V, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Btu/h 7,000 9,000 12,000 9,000 12,000 18,000 24,000 30,000 36,000
Minimum Circuit Ampacity (MCA) A 3 3 3 3 3 3 3 3 3
Max. Fuse A 3 3 3 3 3 3 3 3 3
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM 370/340/265/174/- 378/340/265/174/- 378/340/265/174/- 382/294/194/153/- 382/294/194/153/- 759/530/419/382/- 759/586/419/382/- 871/716/547/447/- 871/716/547/447/-
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) 44/40/35/26/- 44/40/35/26/- 44/40/35/26/- 45/41/32/24/- 45/41/32/24/- 54/49/45/41/27 54/49/45/41/27 56/52/45/38/22 56/52/45/38/22
Dimension (WxDxH) inch 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 31.57x7.87x11.95 45.47x12.01x16.34 45.47x12.01x16.34 49.57x11.14x14.25 49.57x11.14x14.25
Packing (WxDxH) inch 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 42.91x19.09x34.84 42.91x19.09x34.84 42.91x19.09x34.84 42.91x19.09x34.84
Net/Gross Weight lbs. 18.64/22.05 18.64/22.05 18.64/22.05 18.64/22.05 18.64/22.05 45.47/21.06 45.47/21.06 67.16/17.72 67.16/17.72
Room temperature Cooling °F 60~90 60~90 60~90 60~90 60~90 60~90 60~90 60~90 60~90
Room temperature Heating °F 32~86 32~86 32~86 32~86 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 3/8" / 3/4" 3/8" / 3/4" 3/8" / 3/4" 3/8" / 3/4"
Outdoor Model CH-RES06-115V0 CH-RES09-115VO CH-RES12-115VO CH-RES09-230VO CH-RES12-230VO CH-RES18-230VO CH-RES24-230VO CH-REL30-230V0 CH-REL36-230VO
Power Supply Rated V, Ph, Hz 115, 1, 60 115, 1, 60 115, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Voltage Range V 103.5-126.5 103.5-126.5 103.5-126.5 187-253 187-253 187-253 187-253 187-253 187-253
Rated Capacity Range Btu/h 2,600~13,000 2,600~13,000 3,100~19,000 2,600~13,700 2,600~13,700 3,600~20,000 9,700~32,700 6,800~33,900 6,600~36,800
Cooling EER2 Btu/h 6.9 6.9 10.0 6.9 6.9 11.0 11.0 11.0 11.0
SEER2 Btu/h 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
Rated current A 6.9 6.9 12.0 10.0 10.0 11.0 11.0 11.0 11.0
Heating at 47°F COP W/W 24.5 24.5 23.2 24.6 23.1 22.3 19.5 22.3 19.5
HSPF4 4,500~12,800 4,500~12,800 45,00~12,800 4,200~14,200 4,100~14,400 7,600~22,000 11,300~32,700 11,300~32,100 11,400~44,000
HSPF5 7.6 7.6 10.3 3.6 4.3 6.2 13.4 12.6 13.6
Heating at 17°F (AHRI) Rated capacity Btu/h 8.2 8.2 7.6 9.5 8.5 8.3 7.7 7.0 7.0
Minimum Circuit Ampacity A 8,600 8,900 10,200 8,900 9,900 14,500 21,300 21,500 25,600
Max.Fuse (Outdoor Unit) A 20 20 18 12 18 20 25 30 35
Outdoor Air Flow (Max.) CFM 1,235.3 1,235.3 1,235.3 1,235.3 1,235.3 1,794.7 2,235.3 2,235.3 2,205.0
Outdoor Noise Level (Sound Pressure) dB(A) 53.0 53.0 53.0 53.0 53.0 54.0 60.0 60.0 60.0
Dimension (WxDxH) inch 30.12x11.93x21.85 30.12x11.93x21.85 30.12x11.93x21.85 30.12x11.93x21.85 30.12x11.93x21.85 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.24x16.14x31.89
Packing (WxDxH) inch 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 34.92x13.27x24.02 39.17x15.67x29.13 42.91x19.09x34.84 42.91x19.09x34.84 42.91x19.09x34.84
Net/Gross Weight lbs. 64.59/70.11 64.59/70.11 64.59/70.11 64.59/70.11 64.59/70.11 92.59/107.60 128.17/132.28 142.86/154.84 150.35/160.27
Refrigerant Type / Charge oz. R454B/33.51 R454B/33.51 R454B/33.51 R454B/32.45 R454B/32.45 R454B/47.97 R454B/70.55 R454B/84.66 R454B/112.88
Refrigerant Precharge Length # 25 25 25 25 25 25 25 25 25
Additional Charge for Each ft. oz/ft 0.16 0.16 0.16 0.16 0.16 0.32 0.32 0.32 0.32
Design Pressure PSIG 550/340 550/340 550/340 550/340 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 5/8" 3/8" / 5/8" 3/8" / 5/8"
Max. Pipe Length ft. 82 82 82 82 82 98.4 164 164 213.2
Max. Difference in Level ft. 49.2 49.2 49.2 49.2 49.2 65.6 82 82 98.4
Ambient Temperature Cooling °F -13~122 -13~122 -13~122 -13~122 -13~122 -13~122 -13~122 -13~122 -13~122
Heating °F -13~75 -13~75 -13~75 -13~75 -13~75 -13~75 -13~75 -13~75 -13~75
UL
AHRI
Energy Star
NEEP

Multiple Control Methods

Cooper&Hunter’s Olivia Midnight Unit mini split AC can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Frequently Asked Questions

What size mini split do I need for my room?

To effectively cool or heat a space of up to 1,400 sq ft, the Cooper & Hunter Olivia 30,000 BTU mini split is an excellent choice. It's ideal for larger areas or open floor plans, ensuring efficient temperature control.

Can I install a mini split myself?

While DIY installation is possible, it's recommended to hire a professional for optimal performance. The Cooper & Hunter Olivia model does come with installation kit options ranging from 16ft to 50ft, which can simplify the process if you choose to install it yourself.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter Olivia mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, allowing for straightforward installation without the need for additional refrigerant filling immediately.

What voltage does the Cooper & Hunter mini split require?

The Cooper & Hunter Olivia operates on 230V, making it suitable for standard residential electrical systems in most areas. Ensure your home’s electrical setup can accommodate this voltage for optimal performance.

What warranty does the Cooper & Hunter Olivia offer?

The Cooper & Hunter Olivia comes with a robust warranty: a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase. This offers peace of mind for your investment in heating and cooling.

What is the SEER rating of the Cooper & Hunter Olivia?

The Cooper & Hunter Olivia features an impressive SEER rating of 18.0, indicating high energy efficiency. This rating helps you save on energy costs while maintaining comfortable indoor temperatures.