12,000 BTU 230V Ductless Mini Split 1 Way Ceiling Cassette Olivia Series Heat Pump

7% OFF
12,000 BTU Cooper & Hunter Ceiling Cassette Heat Pump for efficient cooling and heating
One Way Cassette Video
White air conditioning unit for Cooper & Hunter 12,000 BTU Ceiling Cassette Heat Pump
Ceiling-mounted air conditioning unit in Cooper & Hunter 12,000 BTU Ceiling Cassette
One-way ceiling cassette Cooper & Hunter 12,000 BTU heat pump from Minisplits4less
Drainage extension comparison for 12,000 BTU Ceiling Cassette by Cooper & Hunter
Smartphone showing thermostat interface for Cooper & Hunter Ceiling Cassette Heat Pump
White air conditioning unit for Cooper & Hunter ceiling cassette mini split system
Sku:N/A
Brand: Cooper & Hunter
Voltage: 230V
SEER Rating: 22.0
WiFi: Included
Zone: Single Zone
Type: 1 Way Cassette
Freon Type: R454B
Compressor Type: Inverter

In stock

Price

$2,087.92
$2,245.08
Installation Kit
  • No Kit
  • 16ft Kit
  • 25ft Kit
  • 50ft Kit
  • 4.8

  • 395 Reviews

93% of buyers have recommended this.

The Cooper&Hunter One Way Cassette Units redefine comfort and efficiency in heating and cooling. Designed for seamless integration into ceilings, these units are perfect for both residential and commercial spaces.

Featuring advanced airflow control, compact design, and quiet operation, they deliver exceptional performance while blending effortlessly into any interior.

Engineered with energy-saving technology, anti-corrosion coatings, and durable construction, these units ensure long-lasting reliability in diverse climates.

Experience the innovation and comfort of the Cooper&Hunter One Way Cassette Units—a smarter solution for your space.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

INDOOR HYPER

Indoor Model CH-RSH06-12MCT1W (Dip Switch 6) CH-RSH06-12MCT1W (Dip Switch 9) CH-RSH06-12MCT1W (Dip Switch 12) CH-RSH18MCT1W
Power Supply (V, Ph, Hz) 208/230,1,60 208/230,1,60 208/230,1,60 208/230,1,60
Cooling Capacity (Btu/h) 6,500 9,000 12,000 16,700
Heating Capacity (Btu/h) 7,400 10,900 12,500 20,000
Minimum Circuit Ampacity (A) 3 3 3 3
Max. Fuse (A) 15 15 15 15
Air Flow (CFM) 353.2/312.0/282.5/247.2/176.6 353.2/312.0/282.5/247.2/176.6 353.2/312.0/282.5/247.2/176.6 400.2/352.0/300.2/207.2 / NVA
Noise Level (dB(A)) 37.5/35.5/26 38/36/33 41/37/33 44/41.5/31
Unit Dimensions (inch) 50.31×13.19×8.98 50.31×13.19×8.98 50.31×13.19×8.98 50.31×13.19×8.98
Packing Dimensions (inch) 57.60×22.48×22.64 57.60×22.48×22.64 57.60×22.48×22.64 57.60×22.48×22.64
Net/Gross Weight (lbs) 45.19/82.45 45.19/82.45 45.19/82.45 45.19/82.45
Cooling Temp. Range (°F) 60~90 60~90 60~90 60~90
Heating Temp. Range (°F) 32~86 32~86 32~86 32~86
Refrigerant Pipes (inch) 1/4"/3/8" 1/4"/3/8" 1/4"/3/8" 1/4"/1/2"

OUTDOOR HYPER

Outdoor Model CH-RHP06F9-230V0 CH-RHP09-230V0 CH-RHP12-230V0 CH-RHP18-230V0
Power Supply - Rated (V, Ph, Hz) 208/230,1,60 208/230,1,60 208/230,1,60 208/230,1,60
Power Supply - Voltage Range (V) 187-253 187-253 187-253 187-253
Cooling - Rated Capacity (range) (Btu/h) 3,600~11,200 4,000~12,900 4,000~13,900 5,700~19,000
Cooling - Rated Current (A) 3 4.5 4.3 8.3
Cooling - EER2 (Btu/h) 15 14.6 13 12.5
Cooling - SEER2 (Btu/h) 22 24 23 20.6
Heating at 47°F - Rated Capacity Range (Btu/h) 3,700~11,500 3,800~13,900 4,600~15,200 8,900~22,000
Heating at 47°F - Rated current (A) 4.0 3.8 4.6 12
Heating at 47°F - COP (W/W) 3.75 3.71 3.56 3.01
Heating at 47°F - HSPF4 12.0 12.1 10 12.2
Heating at 47°F - HSPF5 10.3 9.5 8 9.2
Minimum Circuit Ampacity (A) 12 15 15 19
Max.Fuse (Outdoor Unit) (A) 15 15 15 20
Outdoor Air Flow (Max.) (CFM) 1236.1 1471.5 1471.5 1765.8
Outdoor Noise Level (Sound Pressure) (dB(A)) 53.5 54.5 56 59
Dimension (W×D×H) (inch) 30.12×11.93×21.85 31.69×12.99×21.81 31.69×12.99×21.81 35.04×13.46×26.50
Packing (W×D×H) (inch) 34.92×13.27×24.02 36.02×14.57×24.21 36.02×14.57×24.21 39.17×15.67×29.13
Net/Gross Weight (lbs.) 62.17/67.68 72.75/78.70 72.75/78.70 99.87/107.80
Refrigerant Type / Charge (oz.) R454B/32.45 R454B/35.27 R454B/35.27 R454B/55.38
Refrigerant Precharge Length (ft.) 25 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.16 0.16 0.16
Design Pressure (PSIG) 550/340 550/340 550/340 550/340
Refrigerant Piping Liq. Side / Gas Side (inch) 1/4"/3/8" 1/4"/3/8" 1/4"/3/8" 1/4"/1/2"
Max. Pipe Length (ft.) 82.02 82.02 82.02 98.42
Max. Difference in Level (ft.) 49.21 49.21 49.21 65.62
Ambient Temperature - Cooling (°F) -22~122 -22~122 -22~122 -22~122
Ambient Temperature - Heating (°F) -22~75 -22~75 -22~75 -22~75
Certifications - ETL
Certifications - AHRI
Certifications - Energy Star
Certifications - NEEP

INDOOR HYPER

Indoor Model CH-RSH06-12MCT1W (Dip Switch 9) CH-RSH06-12MCT1W (Dip Switch 12) CH-RSH18MCT1W
Power Supply (V, Ph, Hz) 208/230,1,60 208/230,1,60 208/230,1,60
Cooling Capacity (Btu/h) 9,000 12,000 18,000
Heating Capacity (Btu/h) 11,000 12,000 18,000
Minimum Circuit Ampacity (A) 3 3 3
Max. Fuse (A) 15 15 15
Air Flow (CFM) 353.2/312/282.5/247.2/NVA 353.2/312.0/282.5/247.2/176.6 400.2/352.0/300.2/207.2/NVA
Noise Level (dB(A)) 38.5/34/24 43/37.5/26 44/41/29.5
Unit Dimensions (inch) 50.31×13.19×8.98 50.31×13.19×8.98 50.31×13.19×8.98
Packing Dimensions (inch) 57.60×22.48×22.64 57.60×22.48×22.64 57.60×22.48×22.64
Net/Gross Weight (lbs) 45.19/82.45 45.19/82.45 45.19/82.89
Cooling Temp. Range (°F) 60~90 60~90 60~90
Heating Temp. Range (°F) 32~86 32~86 32~86
Refrigerant Pipes (inch) 1/4"/3/8" 1/4"/3/8" 1/4"/1/2"

OUTDOOR REGULAR

Outdoor Model CH-RES09-230V0 CH-RES12-230V0 CH-RES18-230V0
Power Supply (V, Ph, Hz) 208/230,1,60 208/230,1,60 208/230,1,60
Voltage Range (V) 187-253 187-253 187-253
Cooling - Rated Capacity Range (Btu/h) 3,700~11,400 3,900~13,800 4,000~18,800
Cooling - Rated Current (A) 4.2 4.4 6.4
Cooling - EER2 (Btu/h) 14.4 12.3 12.5
Cooling - SEER2 (Btu/h) 22.1 22.1 22.2
Heating at 47°F - Rated Capacity Range (Btu/h) 4,100~14,300 4,700~15,300 7,600~22,800
Heating at 47°F - Rated Current (A) 4.4 4.7 7.1
Heating at 47°F - COP (W/W) 3.20 3.40 3.30
Heating at 47°F - HSPF4 11.8 10 12.2
Heating at 47°F - HSPF5 9.0 7.8 8.6
Minimum Circuit Ampacity (A) 12 12 18
Max.Fuse (Outdoor Unit) (A) 15 15 20
Outdoor Air Flow (Max.) (CFM) 1236.1 1236.1 1765.8
Outdoor Noise Level (Sound Pressure) (dB(A)) 54.5 54.5 57.5
Dimension (W×D×H) (inch) 30.12×11.93×21.85 30.12×11.93×21.85 35.04×13.46×26.50
Packing (W×D×H) (inch) 34.92×13.27×24.02 34.92×13.27×24.02 39.17×15.67×29.13
Net/Gross Weight (lbs.) 62.17/67.68 62.17/67.68 92.59/100.31
Refrigerant Type / Charge (oz.) R454B/32.45 R454B/32.45 R454B/47.97
Refrigerant Precharge Length (ft.) 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.16 0.16
Design Pressure (PSIG) 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side (inch) 1/4"/3/8" 1/4"/3/8" 1/4"/1/2"
Max. Pipe Length (ft.) 82.00 82.00 98.40
Max. Difference in Level (ft.) 49.20 49.20 65.60
Ambient Temperature Cooling (°F) -13~122 -13~122 -13~122
Ambient Temperature Heating (°F) -13~75 -13~75 -13~75
Certifications ETL, AHRI, Energy Star, NEEP ETL, AHRI, Energy Star, NEEP ETL, AHRI, Energy Star, NEEP