Cooper & Hunter 60,000 BTU Single Zone Universal Floor/Ceiling, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump | No Kit

Cooper & Hunter7-Yr Warranty

CH-N60LCU-230VO60FC
Product specifications
Brand Cooper & Hunter
Voltage 230V
SEER 17
WiFi Included
Zone Single Zone
Type Universal Floor/Ceiling
Freon R410A
Compressor Inverter
$3,639.35 Sold out
Shipping Policy calculated at checkout.
Installation Kit: NO INSTALLATION KIT
FREE Delivery
Out of stock right now We email you the ship date as soon as it lands. For the next arrival call (855) 775-4822.

Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated

Pickup currently unavailable at Medley Warehouse

Add more to unlock bulk savings
FREE Armbridge accessory included with this order — choose yours in the cart (up to $79 value). Orders from $5,000 get a BULK volume discount instead — it saves more than the accessory.

Questions about this system?

Answers in seconds — tap a question below

  • Sized for about 2800–3500 sq ft. Rule of thumb: ~20 BTU per sq ft, and 12,000 BTU = 1 ton (this unit is 60,000 BTU (5-ton)). Ceiling height, insulation, sun and climate shift that — if you're between sizes, size up for hot/humid rooms. Not sure? We'll confirm the right BTU for your space.
  • 12,000 BTU = 1 ton — "tons" is just the older way of stating capacity. So 24,000 BTU = 2 tons, 36,000 = 3 tons, and so on. This system is 60,000 BTU (5-ton). BTU tells you the capacity; SEER2 tells you the efficiency.
  • It uses R410A — a proven, widely serviced refrigerant. The outdoor unit ships pre-charged for a standard line set, so most installs need no extra refrigerant; your licensed, EPA-608-certified installer verifies the charge and tops it off if your line set is longer.
  • Rated SEER2 17.0 — a strong efficiency number, and the higher it is the lower your energy bills. Its inverter compressor ramps up and down instead of cycling on/off, so it holds the temperature steadily, runs quietly, and uses less power than a standard AC or window unit.
  • Needs a dedicated 230V circuit, like a large household appliance, so it can deliver full capacity to larger rooms and multi-zone setups. Your licensed HVAC installer or electrician sets up the correct breaker and disconnect to meet local electrical code.
  • Yes — a big upgrade. It's far more efficient (inverter, SEER2 17.0) and much quieter, since the compressor sits outside instead of in your window or on the floor. It mounts permanently, doesn't block a window, and heats as well as cools year-round. Higher upfront cost, but lower bills and a longer lifespan.
  • Yes to all three. It's an inverter heat pump — cools in summer, heats in winter (even in the cold), far more efficiently than electric heaters. A Dry mode also pulls out humidity, so rooms feel cooler and less muggy.
  • Yes — WiFi is included, so you can set schedules, change the temperature, and even turn it on before you get home, all from the mobile app (and pair it with voice assistants). A standard remote is included too.
  • It should be installed by a licensed, EPA-608-certified HVAC professional — we don't recommend DIY installation. Handling refrigerant requires EPA Section 608 certification under U.S. law, and professional installation keeps the system safe, code-compliant, and your manufacturer warranty valid.
  • Yes — you get full inverter heat-pump technology and the same core features as premium brands without paying for the name, which is how we keep prices low. Shipping is free on U.S. orders over $300, and our team can help with sizing and support.
Hurry to buy! Get your mini-split system with R-410A refrigerant (offer valid until November 27)
Important info
  • R-410A is being phased down in favor of newer refrigerants; inventory is limited.
  • Existing R-410A systems remain serviceable; parts and qualified service are widely available.
  • Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
  • We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Best brands with the best deals

Why buy this mini split from MiniSplitsForLess

  • Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
  • USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
  • Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
  • Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.

What Stands Out

Floor & Ceiling Flexibility

Mounts low on the wall or up near the ceiling — a versatile fit for rooms where a standard wall unit won't work, sized at 60000 BTU.

Inverter Efficiency — SEER2 17

A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 17 on 230V — steady comfort with noticeably lower energy bills.

Right-Sized Coverage

Engineered to heat & cool up to 2800–3500 sq ft — matched capacity so you never over- or under-size the space.

Universal Floor Ceiling

Cooper&Hunter's Universal Floor Ceiling Units deliver efficient heating and cooling solutions, adaptable for floor or ceiling installations. Ideal for residential and commercial spaces, these units ensure consistent comfort with advanced airflow control for even temperature distribution.

Featuring energy-saving technology, they offer eco-friendly and cost-effective performance while operating quietly. Built with durable anti-corrosion coatings, the units are designed to withstand diverse climates, ensuring reliability and longevity.

Their sleek, modern design seamlessly integrates into various layouts, making them a flexible choice for any environment.

Experience innovative, high-performance climate control with Cooper&Hunter's Universal Floor Ceiling Units tailored to your comfort needs.

White air conditioner with purple shield logo and text ’universal floor ceiling’ on a network background.

Warranty and Tech Support Info

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.

Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.

Warranty terms
White air conditioning unit with black fan and copper tubing design.

Energy Efficiency

Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

White office cubicle partition with gray panels and black mesh chairs.

Main Features

Cooper&Hunter's Universal Floor Ceiling Units are adaptable for floor or ceiling installations, ensuring even temperature distribution with advanced airflow control. They feature energy-saving technology for eco-friendly performance and operate quietly for added comfort. Durable anti-corrosion coatings enhance reliability, while their sleek design allows seamless integration into various residential or commercial spaces.

An outdoor air conditioning unit designed for high performance in extreme hot and cold weather.

All Accessories Included

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications

System Specs

System Specs
Cooling Capacity 60,000 BTU
SEER2 17
Zones 1
Voltage 230V
Refrigerant Type R410A
Compressor Inverter
WiFi Included

Series Comparison Table

Technical specifications for every model in the Standard series — this product is one of them.

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Rated Capacity Cooling (Btu/h) 18,000 24,000 36,000 48,000 54,000
Rated Capacity Heating (Btu/h) 20,000 24,000 38,000 50,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 47/43.5/40.5 51/47/42 51.5/48.0/40.5 55/49.5/44.5 55/48/42
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
Indoor Packing (WxDxH) (inch) 45.08x29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature Cooling (°F) 62~90 62~90 62~90 62~90 62~90
Room Temperature Heating (°F) 32~86 32~86 32~86 32~86 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS REGULAR

Outdoor Model CH-ES18-230V0 CH-ES24-230V0 CH-N36LCU-230V0 CH-N48LCU-230V0 CH-N60LCU-230V0
Power Supply Rated (V, Ph, Hz) 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Power Supply Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling Rated Capacity Range (Btu/h) 6,200~18,000 7,700~25,500 11,476~36,000 15,861~48,000 15,000~54,000
Cooling Rated Current (A) 6.29 8.78 19.09 23.6 24.10
Cooling EER2 (Btu/h) 12.5 12.5 8.5 9.3 9.8
Cooling SEER2 (Btu/h) 23 21.2 19 18.9 19.8
Heating at 47°F Rated Capacity Range (Btu/h) 8,100~20,000 11,600~30,900 11,467~38,000 12,159~50,000 17,000~60,000
Heating at 47°F Rated current (A) 8.51 8.77 18.04 25.5 25.5
Heating at 47°F COP (W/W) 2.92 3.66 2.68 2.5 3.03
Heating at 47°F HSPF4 (아) 10 10.3 9 10 9
Heating at 47°F HSPF5 7.7 7.8 7 7.5 7
Minimum Circuit Ampacity (A) 19 23 30 36.5 39
Max.Fuse (Outdoor Unit) (A) 30 30 45 50 50
Outdoor Air Flow (Max.) (CFM) 2,059 2,235 3,000 4,500 2,647
Outdoor Noise Level (Sound Pressure) (dB(A)) 60 61 65 63.5 64
Dimension (WxDxH) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48
Packing (WxDxH) (inch) 39.17x15.67x29.13 42.91x19.69x34.84 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs.) 94.36/100.97 124.78/134.92 155.42/166.23 219.14/249.12 217.15/248.24
Refrigerant Type / Charge (oz.) R410A/56.44 R410A/82.89 R410A/113 R410A/159 R410A/169.3
Refrigerant Precharge Length (ft) 25 25 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.32 0.32 0.32 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"
Max. Pipe Length (ft.) 98.42 164.04 213.25 213.25 213.25
Max. Difference in Level (ft.) 65.62 82.02 98.42 98.42 98.42
Ambient Temperature Cooling (°F) -13~122 -13~122 5~122 5~122 5~122
Ambient Temperature Heating (°F) -13~75 -13~75 5~75 5~75 5~75

INDOOR MODELS HYPER

Indoor Model CH-18MSPHFC-230VI CH-24MSPHFC-230VI CH-36LCFC/I CH-48LCFC/I CH-60LCFC-W
Power Supply Rated (V, Ph, Hz) 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Rated Capacity Cooling (Btu/h) 17,000 24,000 36,000 48,000 55,000
Rated Capacity Heating (Btu/h) 18,000 25,000 39,000 51,000 60,000
Minimum Circuit Ampacity (MCA) (A) 1.9 2.5 1.9 2.3 3
Max. Fuse (A) 15 15 15 15 15
Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) 583/548/485/421 795/759/708/598 1,075/1,036/917/638 1,400/1,353/ 1,118/1,000 1,430/1,384/1,029/795
Indoor Noise Level (Hi/Mi/Lo) (dB(A)) 45.5/43/39 51/47.5/42 52.5/48.5/42.5 55/50/44 54/47/44
Indoor Dimension (WxDxH) (inch) 42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25 64.96x26.57x9.25
45.08×29.72x12.52 45.08x29.72x12.52 53.54x29.72x12.52 67.91x29.72x12.52 67.91x29.72x12.52
Indoor Net/Gross Weight (lbs.) 57.10/68.34 60.63/72.09 69/81.57 87.74/102.29 96.56/111.99
Room Temperature (°F) Cooling: 62~90 Cooling: 62~90 Cooling: 62~90 Cooling: 62 ~ 90 Cooling: 62~ 90
Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86 Heating: 32~86
Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/7/8"

OUTDOOR MODELS HYPER

Outdoor Model CH-HPR18-230V0 CH-HPR24-230VO CH-NHPR36LCU-230V0 CH-NHPR48LCU-230V0 CH-NHPR60LCU-230V0
Power Supply Rated (V, Ph, Hz) 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60 208/230,1, 60
Power Supply Voltage Range (V) 187-253 187-253 187-253 187-253 187-253
Cooling - Rated Capacity Range (Btu/h) 7,800 ~ 19,900 5,400 ~ 26,800 7,780~42,100 2,150~48,000 20,000~55,000
Cooling - Rated Current (A) 8.80 9.55 17.8 24.86 27
Cooling - EER2 (Btu/h) 12.5 11.7 8.8 8.2 9
Cooling SEER2 (Btu/h) 20.5 20.5 17.6 17 17.3
Heating at 47°F - Rated Capacity Range (Btu/h) 8,600~21,500 12,500~30,500 11,500~45,700 11,800~56,300 10,200~62,000
Heating at 47°F - Rated Current (A) 10.9 9.15 19 20.6 26
Heating at 47°F - COP (W/W) 3.01 3.56 2.69 2.9 2.98
Heating at 47°F - HSPF4 9.8 11 10 9.8 10.2
Heating at 47°F - HSPF5 7.5 9 8.2 7.5 8.4
Minimum Circuit Ampacity (A) 20 25 40 40 44
Max.Fuse (Outdoor Unit) (A) 25 35 50 50 60
Outdoor Air Flow (Max.) (CFM) 1,765 2,235 4,500 4,500 4,235
Outdoor Noise Level (Sound Pressure) (dB(A)) 59 62.5 63 65 61
Dimension (W×D×H) (inch) 35.04x13.46x26.50 37.24x16.14x31.89 37.48x16.34x52.48 37.48x16.34x52.48 37.48x16.34x52.48
Packing (W×D×H) (inch) 39.17x15.67x29.13 42.91x19.69x34.84 43.11x19.49x58.27 43.11x19.49x58.27 43.11x19.49x58.27
Net/Gross Weight (lbs.) 100.97/108.03 134.48/144.40 220.24/248.02 227.07/255.73 240.74/271.61
Refrigerant Type / Charge (oz.) R410A / 65.26 R410A / 91.71 R410A / 148.4 R410A / 148 R410A / 169
Refrigerant Precharge Length (ft.) 25 25 25 25 25
Additional Charge for Each ft. (oz/ft) 0.16 0.32 0.32 0.32 0.32
Design Pressure (PSIG) 550/340 550/340 550/340 550/340 550/340
Refrigerant Piping Liquid Side/Gas Side (inch) 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8" /5/8" 3/8" /7/8"
Max. Pipe Length (ft.) 98.42 164.04 213.25 213.25 213.25
Max. Difference in Level (ft.) 65.62 82.02 98.42 98.42 98.42
Cooling Ambient Temperature Range (°F) -22~122 -22~122 5~122 5~122 5~122
Heating Ambient Temperature Range (°F) -22~75 -22~75 -22~75 -22~75 -22~75

Shipping & Returns

  • Free shipping on every order over $300.
  • Delivery estimate for your ZIP is shown in the buy box above.
  • Returns accepted per our policy — unopened units in original packaging.

Warranty

7-year compressor / 5-year parts

  • Limited manufacturer warranty on the compressor and sealed system components.
  • Your order number is the proof of purchase — keep it for any claim.

Multiple Control Methods

Cooper&Hunter’s Universal Floor Ceiling can be managed with a user-friendly remote control, the wall thermostat or the Cooper&Hunter optional phone application. This options offer precise temperature adjustments and optimal climate control for ultimate convenience.

App Promo

Compare with similar items

60,000
up to 2,800 ft²
17.0
R410A
7 years
230V
Included
Standard
Universal Floor/Ceiling
60,000
up to 2,800 ft²
18.0
R454B
7 years
230V
Included
Hyper Heat
Universal Floor/Ceiling

Frequently Asked Questions

What size mini split do I need for my space?

The Cooper & Hunter 60,000 BTU mini split is suitable for areas up to 2500 sq ft, making it an excellent choice for larger rooms or commercial applications. Ensure you calculate your specific room size and BTU requirements to determine if this model meets your needs.

How much does a mini split system cost?

The price of the Cooper & Hunter 60,000 BTU mini split system can vary based on additional installation kits, but expect to invest in a high-efficiency unit with a SEER rating of 17.0, which offers long-term savings on energy bills.

Can I install a mini split myself?

While you can install the Cooper & Hunter mini split yourself, it requires knowledge of HVAC systems and proper tools. Remember, if you opt for DIY installation, the unit comes with options for installation kits up to 50 ft.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter 60,000 BTU mini split system comes pre-charged with R410A refrigerant for up to 25 ft of line set, simplifying installation and ensuring optimal performance right out of the box.

What warranty does Cooper & Hunter offer for this model?

The Cooper & Hunter 60,000 BTU mini split features a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of purchase. This warranty gives you peace of mind regarding your investment.

What SEER rating do I need for energy efficiency?

A SEER rating of at least 16 is recommended for energy efficiency, so the Cooper & Hunter 60,000 BTU unit with a 17.0 SEER rating exceeds this standard, ensuring lower energy costs and better performance.