Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Olivia Wall Mount
The Cooper&Hunter Olivia Unit mini split AC blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter mini split AC for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units mini split AC feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase mini split AC, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor and Outdoor Hyper
| Indoor Model | CH-R006MOLVWM-230VI | CH-R009MOLVWM-230VI | CH-R012MOLVWM-230VI | CH-R018MOLVWM-230VI | CH-R024MOLVWM-230VI | CH-R033HOLVWM-230VI |
|---|---|---|---|---|---|---|
| Power Supply Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 6,000 | 9,000 | 12,000 | 18,000 | 23,000 | 33,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 294.3/225.4/176.8/141.3/NA | 382.6/293.1/194.2/153.0/NA | 382.6/293.1/194.2/153.0/NA | 759.3/530.4/419.1/382.6/NA | 759.3/586.5/419.1/382.6/NA | 829.6/716.6/592.7/447.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 42.0/37.0/32.0/24.0/NA | 42.0/37.0/32.0/24.0/NA | 43.0/37.0/32.0/24.0/NA | 52.5/44.0/40.5/35.2/25.0 | 54.5/49.0/45.3/41.3/27.0 | 56.0/49.5/45.3/41.3/27.0 |
| Dimension (WxDxH) inch | 28.7x7.87x11.81 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.60x9.21x13.27 | 42.60x9.21x13.27 | 52.76x15.16x17.72 |
| Packing (WxDxH) inch | 31.10x10.63x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.40x16.34 | 45.47x12.40x16.34 | 52.76x15.16x17.72 |
| Net/Gross Weight lbs. | 17.64/23.15 | 18.96/24.25 | 18.96/24.25 | 30.42/39.68 | 30.86/40.56 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
| Outdoor Model | CH-RHP06F9-230VO | CH-RHP09-230VO | CH-RHP12-230VO | CH-RHP18-230VO | CH-RHP24-230VO | CH-RHP33-230VO |
|---|---|---|---|---|---|---|
| Power Supply Rated V, Ph, Hz | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range V | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Capacity Range Btu/h | 2,500~11,500 | 3,600~13,500 | 3,600~13,500 | 8,400~20,200 | 16,000~24,500 | 15,000~35,000 |
| Cooling EER2 Btu/h | 16.0 | 15.0 | 13.2 | 13.0 | 12.5 | 11.7 |
| SEER2 Btu/h | 25.3 | 26.0 | 24.0 | 21.7 | 22.3 | 19.5 |
| Rated current A | 3.1 | 4.0 | 4.1 | 9.0 | 8.4 | 14.1 |
| Heating at 47°F COP W/W | 3.80 | 3.63 | 3.63 | 3.54 | 3.05 | 3.22 |
| HSPF4 | 14.6 | 12.5 | 10.5 | 10.8 | 13.3 | 10.5 |
| HSPF5 | 11.2 | 10.1 | 8.0 | 8.8 | 9.6 | 8.3 |
| Heating at 17°F (AHRI) Rated capacity Btu/h | 8,600 | 12,800 | 12,800 | 19,800 | 24,400 | 30,200 |
| Minimum Circuit Ampacity A | 12 | 15 | 15 | 19 | 24.9 | 35 |
| Max.Fuse (Outdoor Unit) A | 15 | 15 | 15 | 20 | 25 | 40 |
| Outdoor Air Flow (Max.) CFM | 1,235.3 | 1,470.6 | 1,470.6 | 1,764.7 | 2,235.3 | 2,235.3 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 53.0 | 56.0 | 56.0 | 59.0 | 61.0 | 63.5 |
| Dimension (WxDxH) inch | 30.12x11.93x21.85 | 31.69x12.99x21.81 | 31.69x12.99x21.81 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.44x19.09x34.84 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 36.02x14.57x24.21 | 36.02x14.57x24.21 | 39.17x15.67x29.13 | 42.91x19.69x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 62.17/67.68 | 72.75/78.70 | 72.75/78.70 | 99.87/107.80 | 130.29/141.31 | 156.87/197.99 |
| Refrigerant Type / Charge oz. | R454B/32.45 | R454B/35.27 | R454B/35.27 | R454B/55.38 | R454B/63.49 | R454B/87.13 |
| Refrigerant Precharge Length # | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. oz/ft | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 | 0.32 |
| Design Pressure PSIG | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
| Max. Pipe Length ft. | 82 | 82 | 82 | 98.4 | 164 | 164 |
| Max. Difference in Level ft. | 49.2 | 49.2 | 49.2 | 65.6 | 82 | 82 |
| Ambient Temperature Cooling °F | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Heating °F | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| NEEP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Indoor and Outdoor Regular
| Indoor Model | CH-R060LVWM-115VI | CH-R09OLVWM-115VI | CH-R120LVWM-115VI | CH-RO9MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R30MELVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated | 115V, 1, 60 | 115V, 1, 60 | 115V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 370/340/265/174/- | 378/340/265/174/- | 378/340/265/174/- | 382/294/194/153/- | 382/294/194/153/- | 759/530/419/382/- | 759/586/419/382/- | 871/716/547/447/- | 871/716/547/447/- |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 44/40/35/26/- | 44/40/35/26/- | 44/40/35/26/- | 45/41/32/24/- | 45/41/32/24/- | 54/49/45/41/27 | 54/49/45/41/27 | 56/52/45/38/22 | 56/52/45/38/22 |
| Dimension (WxDxH) inch | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 45.47x12.01x16.34 | 45.47x12.01x16.34 | 49.57x11.14x14.25 | 49.57x11.14x14.25 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
| Outdoor Model | CH-RES06-115V0 | CH-RES09-115VO | CH-RES12-115VO | CH-RES09-230VO | CH-RES12-230VO | CH-RES18-230VO | CH-RES24-230VO | CH-REL30-230V0 | CH-REL36-230VO |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated V, Ph, Hz | 115, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range V | 103.5-126.5 | 103.5-126.5 | 103.5-126.5 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Capacity Range Btu/h | 2,600~13,000 | 2,600~13,000 | 3,100~19,000 | 2,600~13,700 | 2,600~13,700 | 3,600~20,000 | 9,700~32,700 | 6,800~33,900 | 6,600~36,800 |
| Cooling EER2 Btu/h | 6.9 | 6.9 | 10.0 | 6.9 | 6.9 | 11.0 | 11.0 | 11.0 | 11.0 |
| SEER2 Btu/h | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 |
| Rated current A | 6.9 | 6.9 | 12.0 | 10.0 | 10.0 | 11.0 | 11.0 | 11.0 | 11.0 |
| Heating at 47°F COP W/W | 24.5 | 24.5 | 23.2 | 24.6 | 23.1 | 22.3 | 19.5 | 22.3 | 19.5 |
| HSPF4 | 4,500~12,800 | 4,500~12,800 | 45,00~12,800 | 4,200~14,200 | 4,100~14,400 | 7,600~22,000 | 11,300~32,700 | 11,300~32,100 | 11,400~44,000 |
| HSPF5 | 7.6 | 7.6 | 10.3 | 3.6 | 4.3 | 6.2 | 13.4 | 12.6 | 13.6 |
| Heating at 17°F (AHRI) Rated capacity Btu/h | 8.2 | 8.2 | 7.6 | 9.5 | 8.5 | 8.3 | 7.7 | 7.0 | 7.0 |
| Minimum Circuit Ampacity A | 8,600 | 8,900 | 10,200 | 8,900 | 9,900 | 14,500 | 21,300 | 21,500 | 25,600 |
| Max.Fuse (Outdoor Unit) A | 20 | 20 | 18 | 12 | 18 | 20 | 25 | 30 | 35 |
| Outdoor Air Flow (Max.) CFM | 1,235.3 | 1,235.3 | 1,235.3 | 1,235.3 | 1,235.3 | 1,794.7 | 2,235.3 | 2,235.3 | 2,205.0 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 53.0 | 53.0 | 53.0 | 53.0 | 53.0 | 54.0 | 60.0 | 60.0 | 60.0 |
| Dimension (WxDxH) inch | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.24x16.14x31.89 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 39.17x15.67x29.13 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 92.59/107.60 | 128.17/132.28 | 142.86/154.84 | 150.35/160.27 |
| Refrigerant Type / Charge oz. | R454B/33.51 | R454B/33.51 | R454B/33.51 | R454B/32.45 | R454B/32.45 | R454B/47.97 | R454B/70.55 | R454B/84.66 | R454B/112.88 |
| Refrigerant Precharge Length # | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. oz/ft | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure PSIG | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
| Max. Pipe Length ft. | 82 | 82 | 82 | 82 | 82 | 98.4 | 164 | 164 | 213.2 |
| Max. Difference in Level ft. | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 | 65.6 | 82 | 82 | 98.4 |
| Ambient Temperature Cooling °F | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Heating °F | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| NEEP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit mini split AC can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my room?
For a space up to 550 sq ft, the Cooper & Hunter Olivia Hyper Heat model with 12,000 BTU is an excellent choice. This unit provides efficient heating and cooling, making it ideal for medium-sized rooms.
Can I install a mini split myself?
While the Cooper & Hunter Olivia Hyper Heat 12,000 BTU model is designed for DIY installation, it is essential to have basic HVAC knowledge. If you choose to install the unit yourself, ensure you have the necessary tools and follow the installation guidelines provided.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia Hyper Heat 12,000 BTU unit comes pre-charged with R454B refrigerant for up to 25 ft of line set. This feature simplifies the installation process, allowing for quicker setup and operation.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter Olivia Hyper Heat operates on a 230V power supply, making it suitable for standard residential electrical systems. Ensure your home is equipped with the appropriate voltage for optimal performance.
What warranty does the Cooper & Hunter Olivia Hyper Heat offer?
This model includes a warranty of 5 years on parts and 7 years on the compressor, provided you register the unit within 30 days of purchase. This warranty assures you of the durability and reliability of the system.
What is the SEER rating of the Cooper & Hunter Olivia Hyper Heat?
The Cooper & Hunter Olivia Hyper Heat boasts an impressive SEER rating of 24.0, indicating high energy efficiency. This rating means you can expect lower energy bills while enjoying comfortable heating and cooling throughout the year.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Splits for Older Homes Without Ductwork: The Complete 2026 Retrofit Guide
The 2026 Retrofit Guide Mini Splits for Older Homes Without Ductwork Look, I love old homes. I’ve spent more weekends...
36,000 BTU Mini Split: The Honest 3-Ton Buying Guide
Expert Buying Guide 36,000 BTU Mini Split: The Honest 3-Ton Buying Guide A few years ago, I got called out...
6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide)
2026 HVAC Guide 6000 BTU Mini Split: Best Compact Units for Small Rooms (2026 Guide) I used to think bigger...