Jimmy K.Verified purchase
Great unit !!! Cooling good and simple installation. I would highly recommend !!!
Cooper & Hunter7-Yr Warranty126 shoppers interested
| SEER | |
|---|---|
| WiFi | |
| Brand | |
| Voltage | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Out of stock right now
For the next arrival, call (855) 775-4822.
— we’ll fill in your ZIP. Used only for delivery dates and pickup.
FREE shipping to We don’t ship to .Pick up at Medley, FL ·
9400 Northwest 104th Street, Suite 150, Medley, FL 33178
Buy with Shop skips your pickup choice; Add to cart keeps it.
Please note that all delivery dates and estimated transit times are approximate and are not guaranteed. Delivery times may vary due to carrier delays, weather, holidays, peak shipping periods, or other circumstances beyond our control. How delivery dates are calculated
Answers in seconds — tap a question below
Rated 5.0 out of 5 by 4 buyers of this model.
Verified reviews first · newest first
Jimmy K.Verified purchase
Great unit !!! Cooling good and simple installation. I would highly recommend !!!
Anthony F.
My old system was failing, so I upgraded to this ductless mini split heat pump. It keeps our space at the perfect temperature.
Elijah W.
Couldn’t believe how fast 12,000 BTU 230V Ductless Mini Split AC Wall Mounted Olivia Midnight Edition Heat Pump. It’s been whisper-quiet, and I couldn’t be happier with the results.
Liam G.
The 12,000 BTU Olivia Midnight has been reliable and stronger than I expected.
Reviews of MiniSplitsForLess as a store on Trustpilot: ordering, shipping and support.
See all 591 reviews on Trustpilot ›Reviews of MiniSplitsForLess as a store on Google: ordering, shipping and support.
A slim, quiet indoor head mounts high on the wall and delivers 12000 BTU of Olivia Midnight-series heating & cooling — modern looks with whisper-quiet operation.
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 23.1 on 230V — steady comfort with noticeably lower energy bills.
Heats & cools up to about 550 sq ft at average conditions (about 22 BTU per sq ft).
The Cooper&Hunter Olivia Midnight Unit blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Cooper&Hunter’s Olivia Midnight Series units are specifically designed to provide maximum comfort in smaller spaces. Featuring advanced inverter technology, these units deliver energy-efficient heating and cooling, while quiet operation ensures a peaceful environment. With precise airflow control and seamless integration into any interior, the Olivia Midnight Series offers reliable, consistent comfort in even the tightest spaces.

With your purchase, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

| Model | CH-RB12MOLVWM-230VI |
|---|---|
| Unit Dimensions (WxDxH) | 31.57x7.87x11.61 in |
| Net/Gross Weight | 18.74/24.25 lb |
| Packing Dimensions (WxDxH) | 34.45x11.22x14.96 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/1/2" |
| Noise Level (Hi/Med/Lo) | 42/36/25 dB |
| Airflow (Turbo/Hi/Mi/Lo) | 341.18/291.18/194.12/152.94 CFM |
| Dehumidification | 2.83 pt/h |
| Drain Pipe Diameter | 5/8" |
| Controller | RG10K-exclusive remote |
| Model | CH-RES12-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 30.12 x 11.93 x 21.85 in |
| Net/Gross Weight | 62.17/67.68 lb |
| Packing Dimensions (WxDxH) | 34.92 x 13.27 x 24.02 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 12 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" |
| Noise Level | 54 dB |
| Airflow | 1,235.3 CFM |
| Dehumidification | 2.75 pt/h |
| Cooling Capacity | 12,000 BTU |
|---|---|
| SEER2 | 23.1 |
| Zones | 1 |
| Voltage | 230V |
| Refrigerant Type | R454B |
| Compressor | Inverter |
| WiFi | Included |
| Heating Capacity | 12,000 (4,100~14,400) BTU/h |
| Cooling Capacity Range | 12,000 (2,600~13,700) BTU/h |
| Operating Range (Cooling) | -13 ~ 122 °F |
| Operating Range (Heating) | -13~75 °F |
| Max. Pipe Length | 82 ft |
| Refrigerant Precharge | 25 ft |
| Max Height Difference | 49.2 ft |
| COP | 3.69 |
Technical specifications for every model in the Olivia Midnight series — this product is one of them.
| Indoor Model | CH-RB06MOLVWM-230VI | CH-RB09MOLVWM-230VI | CH-RB12MOLVWM-230VI | CH-RB18MOLVWM-230VI | CH-RB24MOLVWM-230VI |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity | 6,000 Btu/h | 9,000 Btu/h | 12,000 Btu/h | 18,000 Btu/h | 23,000 Btu/h |
| Minimum Circuit Ampacity (MCA) | 3 A | 3 A | 3 A | 3 A | 3 A |
| Max. Fuse | 15 A | 15 A | 15 A | 15 A | 15 A |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 294.3/235.4/176.6/141.3/ \A | 382.6/294.3/194.2/153.0/NA | 382.6/294.3/194.2/153.0 / / | 759.3/500.3/441.4/ 370.8 / / | 799.3/588.6/459.1/ 382.6 / / |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | 42/37/32/24/20 dB(A) | N\A/38.5/33/24/20.5 dB(A) | N\A/42/35.5/22.5/20 dB(A) | 54.5/45/40/24.5/20 dB(A) | 54.5/45.5/43.5/34.5/20.5 dB(A) |
| Indoor | |||||
| Dimension (WxDxH) | 28.70x7.87x11.50 inch | 31.57x7.87x11.61 inch | 31.57x7.87x11.61 inch | 42.60x9.21x13.27 inch | 42.60x9.21x13.27 inch |
| Packing (WxDxH) | 31.10x10.63x14.76 inch | 34.45x11.22x14.96 inch | 34.45x11.22x14.96 inch | 45.47x12.40x16.34 inch | 45.47x12.40x16.34 inch |
| Net/Gross Weight | 17.64/23.15 lbs. | 18.96/24.25 lbs. | 18.96/24.25 lbs. | 30.42/39.68 lbs. | 30.86/40.56 lbs. |
| Room temperature | |||||
| Cooling | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F | 60 ~ 90 °F |
| Heating | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F | 32 ~ 86 °F |
| Outdoor Model | CH-RHP06F9-230VO | CH-RHP09-230VO | CH-RHP12-230VO | CH-RHP18-230V0 | CH-RHP24-230VO |
|---|---|---|---|---|---|
| Power Supply | |||||
| Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling | |||||
| Rated Capacity (range) (Btu/h) | 2,500~11,500 | 3,600~13,500 | 3,600~13,500 | 8,400~20,200 | 16,800~24,500 |
| Rated Current (A) | 3.1 | 4.0 | 4.1 | 9.0 | 8.4 |
| EER2 (Btu/h) | 16.0 | 15.0 | 13.2 | 13.0 | 12.5 |
| SEER2 (Btu/h) | 25.3 | 26.0 | 24.0 | 21.7 | 22.3 |
| Heating at 47°F | |||||
| Rated Capacity (range) (Btu/h) | 3,200~10,700 | 3,800~16,000 | 3,800~16,000 | 10,900~23,000 | 11,800~28,100 |
| Rated current (A) | 4.0 | 4.3 | 4.3 | 9.5 | 11.2 |
| COP (W/W) | 3.80 | 3.83 | 3.83 | 3.54 | 3.05 |
| HSPF4 | 14.6 | 12.5 | 10.5 | 10.8 | 13.3 |
| HSPF5 | 11.2 | 10.1 | 8.0 | 8.8 | 9.6 |
| Heating at 17°F (AHRI) | |||||
| Rated capacity (Btu/h) | 8,600 | 12,800 | 12,800 | 19,800 | 24,400 |
| Minimum Circuit Ampacity (A) | 12 | 15 | 15 | 19 | 24.9 |
| Max.Fuse (Outdoor Unit) (A) | 15 | 15 | 15 | 20 | 25 |
| Outdoor Air Flow (Max.) (CFM) | 1,235.3 | 1,470.6 | 1,470.6 | 1,764.7 | 2,235.3 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 53.0 | 56.0 | 56.0 | 59.0 | 61.0 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 31.69x12.99x21.81 | 31.69x12.99x21.81 | 35.04x13.46x26.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 36.02x14.57x24.21 | 36.02x14.57x24.21 | 39.17x15.67x29.13 | 42.91x19.66x34.84 |
| Net/Gross Weight (lbs.) | 62.17/67.68 | 72.75/78.70 | 72.75/78.70 | 98.87/107.80 | 130.29/141.31 |
| Refrigerant Type / Charge (oz.) | R4548/32.45 | R4548/35.27 | R4548/35.27 | R4548/55.38 | R4548/63.49 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" |
| Max. Pipe Length (ft.) | 82 | 82 | 82 | 98.4 | 164 |
| Max. Difference in Level (ft.) | 49.2 | 49.2 | 49.2 | 65.6 | 82 |
| Ambient Temperature | |||||
| Cooling (-*F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Heating (*F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Certifications | |||||
| ETL | ✓ | ✓ | ✓ | ✓ | ✓ |
| AHRI | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ |
| NEEP | ✓ | ✓ | ✓ | ✓ | ✓ |
| CH-RB090LVWM-115VI | CH-RB120LVWM-115VI | CH-RB09MOLVWM-230VI | CH-RB12MOLVWM-230VI | CH-RB18MOLVWM-230VI | CH-RB24MOLVWM-230VI | |
|---|---|---|---|---|---|---|
| Power Supply | 115,1, 60 | 115,1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| MCA | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | 370.8/306.1/235.4/188.4/141.3 | 370.8/306.1/235.4/188.4/141.3 | 382.6/294.3/194.2/153.0/ N/A | 382.6/294.3/194.2/153.0 / / | 759.3/500.3/441.4/ 370.8 / / | 759.3/588.6/459.1/382.6 / / |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | 44.0/40.5/35.0/26.5/17.5 | 44.0/40.5/35.0/26.5/17.5 | 45.5/42/36/21/19.5 | 46/43/37/20/19 | 54/45/40/26/20 | 54.0/48.5/43.5/27.5/20.5 |
| Dimension (WxDxH) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.60x9.21x13.27 |
| Packing (WxDxH) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.40x16.34 | 45.47x12.40x16.34 |
| Net/Gross Weight | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.96/24.25 | 30.42/39.68 | 30.86/40.56 |
| Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| CH-RES09-115VO | CH-RES12-115VO | CH-RES09-230VO | CH-RES12-230VO | CH-RES18-230VO | CH-RES24-230VO | |
|---|---|---|---|---|---|---|
| Power Supply | 115,1, 60 | 115,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Voltage Range | 103.5~126.5 | 103.5~126.5 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Capacity (Btu/h) | 2,600~13,000 | 3,100~10,900 | 2,600~13,000 | 2,600~13,700 | 3,600~20,000 | 9,700~27,000 |
| Rated Current (A) | 6.9 | 10.0 | 4.6 | 4.5 | 6.0 | 8.0 |
| Max. Fuse (A) | 15.0 | 15.0 | 15.0 | 15.0 | 20.0 | 25.0 |
| EER2 | 24.5 | 23.2 | 24.6 | 24.1 | 23.0 | 23.5 |
| SEER2 | 24.5 | 24.6 | 24.6 | 23.1 | 24.0 | 23.5 |
| Rated Capacity (Heating, Btu/h) | 4,500~12,800 | 4,500~12,800 | 4,200~14,200 | 4,100~14,400 | 7,600~22,000 | 11,300~32,700 |
| Rated Current (Heating, A) | 7.6 | 10.3 | 3.6 | 4.3 | 6.2 | 10.4 |
| COP (W/W) | 3.6 | 3.6 | 3.6 | 3.9 | 3.8 | 3.8 |
| HSPF4 | 8.2 | 7.6 | 9.5 | 8.5 | 8.3 | 7.7 |
| HSPF5 | 8,900 | 10,200 | 8,900 | 9,900 | 14,500 | 21,300 |
| Minimum Circuit Ampacity (A) | 18 | 18 | 12 | 12 | 18 | 24 |
| Max. Fuse (Outdoor Unit) (A) | 20 | 20 | 15 | 15 | 20 | 25 |
| Outdoor Air Flow (Max.) (CFM) | 1,235.3 | 1,235.3 | 1,235.3 | 1,235.3 | 1,764.7 | 2,235.3 |
| Outdoor Noise Level (dB(A)) | 53.0 | 53.0 | 52.5 | 54.0 | 59.0 | 60.0 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 35.04x13.46x26.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 39.17x15.67x29.13 | 42.91x19.69x34.84 |
| Net/Gross Weight (lbs.) | 64.59/70.11 | 64.59/70.11 | 62.17/67.68 | 62.17/67.68 | 92.59/100.31 | 122.13/132.28 |
| Refrigerant Type / Charge (oz.) | R454B/33.51 | R454B/33.51 | R454B/32.45 | R454B/32.45 | R454B/47.97 | R454B/70.55 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4\" / 3/8\" | 1/4\" / 3/8\" | 1/4\" / 3/8\" | 1/4\" / 3/8\" | 1/4\" / 1/2\" | 3/8\" / 5/8\" |
| Max. Pipe Length (ft.) | 82 | 82 | 82 | 82 | 98.4 | 164 |
| Max. Difference in Level (ft.) | 49.2 | 49.2 | 49.2 | 49.2 | 65.6 | 82 |
| Ambient Temp Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temp Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| ETL | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| AHRI | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Energy Star | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| NEEP | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
| Outdoor condenser | CH-RES12-230VO |
|---|---|
| Indoor unit | CH-RB12MOLVWM-230VI |
| Remote controller | RG10K-exclusive remote |
Installation kit is not included in the selected option — pick 16ft, 25ft or 50ft above to add one.
7-year compressor / 5-year parts
Cooper&Hunter’s Olivia Midnight Unit can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
For a room size of up to 550 sq ft, the Cooper & Hunter Olivia Midnight 12,000 BTU mini split is ideal. With its powerful 12k BTU output, it efficiently cools and heats spaces of this size.
While some experienced DIYers may attempt installation, it is recommended to hire a professional for the Cooper & Hunter Olivia Midnight system. Proper installation ensures optimal performance and efficiency, especially given its 23.1 SEER rating.
Yes, the Cooper & Hunter Olivia Midnight mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, making installation easier. This feature ensures that you have the necessary refrigerant for efficient operation right out of the box.
This mini split operates on a 230V electrical system, which is standard for many residential installations. Ensure your electrical setup is compatible to maximize performance and efficiency.
The Cooper & Hunter Olivia Midnight comes with a solid warranty: a 5-year parts warranty and a 7-year compressor warranty, provided you register the unit within 30 days of purchase. This coverage offers peace of mind for your investment.
A SEER rating of 23.1, like that of the Cooper & Hunter Olivia Midnight, is considered highly efficient and ideal for energy-saving cooling and heating. For maximum efficiency, look for systems with a SEER rating above 16, especially in warmer climates.
If you're thinking about turning your home into a smart home, you're not alone.
Rental property · ADU purchasing guide Mini Splits for Rental Units and ADUs: Per-Unit Cost and Tenant Metering Updated November...
Ductless HVAC Basics What Is a Mini Split? Parts, How It Works & 2026 Costs Pre-Purchase Guide 2026 Edition HVAC...
2026 Cost & Sizing Guide Whole House Mini Split Systems: 2026 Costs, Zone Counts & Sizing Multi-Zone Olivia & Olivia...
Pick a system type to get started.
Saved items (0)View list ›Not sure what size you need? Call (855) 775-4822 — we’ll help you choose.