Cooper & Hunter Olivia Hyper Heat 9,000 BTU Single Zone Wall Mount, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump | No Kit










Cooper & Hunter
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Important info
- R-410A is being phased down in favor of newer refrigerants; inventory is limited.
- Existing R-410A systems remain serviceable; parts and qualified service are widely available.
- Check local codes and rebates. Some incentives prioritize high-efficiency heat pumps (R-32/R-454B).
- We stock both R-410A and next-gen options—choose what fits your timeline and budget.
Browse: R-410A systems · R-32 · R-454B
Olivia Wall Mount
The Cooper&Hunter Olivia Unit mini splits AC blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit mini splits AC is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter mini splits AC products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s mini split AC Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units mini split AC feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase mini split AC, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
INDOOR MODELS HYPER
| Indoor Model | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
INDOOR MODELS REGULAR
| Indoor Model | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
OUTDOOR MODELS
| Outdoor Regular | CH-ES06-115V0 | CH-ES09-115VO | CH-ES12-115VO | CH-ES09-230V0 | CH-ES12-230V0 | CH-ES18-230V0 | CH-ES24-230V0 |
|---|---|---|---|---|---|---|---|
| Power Supply | 115V, 1Ph, 60Hz | 115V, 1Ph, 60Hz | 115V, 1Ph, 60Hz | 208/230V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 103.5~126.5 | 103.5~126.5 | 103.5~126.5 | 187~253 | 187~253 | 187~253 | 187~253 |
| Rated Capacity (range) Cooling (Btu/h) | 6,300 (3,900~13,200) | 9,000 (3,900~13,200) | 12,000 (3,900~13,800) | 9,000 (2,560~11,900) | 12,000 (3,080~13,300) | 18,000 (7,320~19,500) | 24,000 (9,200~25,000) |
| Rated Current Cooling (A) | 3.8 | 6.5 | 8.7 | 3.48 | 4.5 | 6.31 | 10.35 |
| EER2 (Btu/h) | 13.6 | 13.8 | 12.5 | 14.7 | 13 | 13.5 | 13 |
| SEER2 (Btu/h) | 23 | 23 | 22.7 | 24 | 23.1 | 24 | 21 |
| Rated Capacity (range) Heating (Btu/h) | 7,000 (5,000~12,680) | 10,000 (5,000~12,680) | 12,000 (5,000~12,680) | 10,000 (3,480~13,000) | 12,000 (4,260~13,560) | 18,000 (6,620~21,200) | 26,000 (10,350~26,410) |
| Rated current Heating (A) | 4.8 | 6.7 | 8.7 | 3.48 | 4.5 | 6.31 | 10.35 |
| Heating at 47°F COP (W/W) | 3.91 | 3.91 | 3.52 | 3.66 | 3.4 | 3.74 | 3.15 |
| HSPF4 | 9.8 | 9.8 | 10.4 | 11.6 | 10.8 | 10.5 | 8.5 |
| HSPF5 | 7.6 | 7.6 | 7.6 | 8.8 | 8 | 7.9 | 6.3 |
| Minimum Circuit Ampacity (A) | 19 | 19 | 19 | 13 | 13 | 19 | 23 |
| Max.Fuse (A) | 25 | 25 | 25 | 15 | 15 | 30 | 30 |
| Outdoor Air Flow (Max.) (CFM) | 794 | 794 | 794 | 1,294 | 1,294 | 2,058 | 2,235 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 54 | 54 | 54 | 53 | 54.5 | 53.8 | 62 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 35.04x15.48x28.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 39.17x15.67x29.13 | 42.91x19.69x34.64 |
| Net/Gross Weight (lbs.) | 66.80/72.31 | 66.80/72.31 | 66.80/72.31 | 63.71/69.00 | 63.71/69.00 | 94.36/100.97 | 124.78/134.92 |
| Refrigerant Type / Charge | R410A/38.81 | R410A/38.81 | R410A/38.81 | R410A/38.1 | R410A/38.1 | R410A/56.44 | R410A/82.89 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge For Each ft. (oz/ft.) | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
| Max. Pipe Length (ft.) | 82 | 82 | 82 | 82 | 82 | 98 | 164 |
| Max. Difference In Level (ft.) | 32.8 | 32.8 | 32.8 | 32.8 | 32.8 | 66 | 82 |
| Ambient Temp. Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temp. Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certifications UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Certifications AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Certifications Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Outdoor Hyper | CH-HPR06F9-230VO | CH-HPR09-230V0 | CH-HPR12-230V0 | CH-HPR18-230V0 | CH-HPR24-230V0 |
|---|---|---|---|---|---|
| Power Supply - Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Power Supply - Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling - Rated Capacity (range) (Btu/h) | 6,000 (2,500-11,800) | 9,000 (3,700~13,300) | 12,000 (3,700~13,300) | 18,000 (8,400~20,200) | 23,000 (4,650~26,600) |
| Cooling - Rated Current (A) | 4.75 | 4 | 4.25 | 9.2 | 11.38 |
| Cooling - EER2 (Btu/h) | 15 | 15.8 | 13 | 13 | 12.5 |
| Cooling - SEER2 (Btu/h) | 23.5 | 26.4 | 23.1 | 22 | 22.3 |
| Heating at 47°F - Rated Capacity (range) (Btu/h) | 7,000 (3,400-11,230) | 12,000 (5,100~14,300) | 12,000 (5,100~14,300) | 18,000 (6,000~23,000) | 26,000 (9.550~27,000) |
| Heating at 47°F - Rated current (A) | 3.76 | 4 | 4.25 | 9.2 | 11.38 |
| Heating at 47°F - COP (W/W) | 3.76 | 3.9 | 3.6 | 3.35 | 3 |
| Heating at 47°F - HSPF4 | 12 | 11.6 | 10.5 | 10.6 | 10.3 |
| Heating at 47°F - HSPF5 | 10 | 8.5 | 8 | 7.9 | 7.7 |
| Minimum Circuit Ampacity (A) | 13 | 15 | 15 | 20 | 25 |
| Max.Fuse (A) | 15 | 15 | 15 | 25 | 35 |
| Outdoor Air Flow (Max.) (CFM) | 1,294 | 1,324 | 1,324 | 1,765 | 2,235 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 53.5 | 55.5 | 56 | 58 | 62.5 |
| Dimension (WxDxH) (inch) | 30.12x11.93x21.85 | 31.69x12.99x21.81 | 31.69x12.99x21.81 | 35.04x13.46x26.50 | 37.24x16.14x31.89 |
| Packing (WxDxH) (inch) | 34.92x13.27x24.02 | 36.02x14.57x24.21 | 36.02x14.57x24.21 | 39.17x15.67x29.13 | 42.91x19.69x34.84 |
| Net/Gross Weight (lbs) | 63.71/69 | 74.07/80.25 | 73.63/79.37 | 100.97/108.03 | 134.48/144.40 |
| Refrigerant Type / Charge (oz.) | R410A/38.1 | R410A/41.62 | R410A/41.62 | R410A/65.2 | R410A/91.7 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping - Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
| Refrigerant Piping - Max. Pipe Length (ft.) | 82 | 82 | 82 | 98 | 164 |
| Refrigerant Piping - Max. Difference in Level (ft.) | 32.8 | 32.8 | 32.8 | 66 | 82 |
| Ambient Temperature - Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Ambient Temperature - Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Certifications - UL | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certifications - AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certifications - Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit mini split AC can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my room?
For a space up to 350 sq ft, the Cooper & Hunter Olivia Hyper Heat with 9,000 BTU is an ideal choice. This unit efficiently cools and heats smaller rooms, providing optimal comfort.
How much does a Cooper & Hunter mini split system cost?
The price of the Cooper & Hunter Olivia Hyper Heat system varies based on the installation kit chosen, but expect to invest in a unit that delivers 9,000 BTU and a high SEER rating of 26.4 for excellent efficiency.
Can I install a mini split myself?
While DIY installation is possible, it requires technical knowledge of HVAC systems. The Cooper & Hunter Olivia Hyper Heat comes with detailed instructions, but you must ensure correct installation, especially considering its 230V requirement.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia Hyper Heat unit is pre-charged with R410A refrigerant for up to 25 ft of line set, making the installation process more straightforward if you choose to install it yourself.
What kind of warranty does the Cooper & Hunter Olivia Hyper Heat offer?
The Cooper & Hunter Olivia Hyper Heat features a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase for full coverage.
What is the SEER rating of the Cooper & Hunter Olivia Hyper Heat?
The Cooper & Hunter Olivia Hyper Heat boasts an impressive SEER rating of 26.4, indicating high energy efficiency. This rating is essential for reducing energy costs while maintaining comfortable temperatures in your space.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins?
Buyer's Guide • Cooling Systems Wall AC Unit vs. Mini Split: Which Cooling System Actually Wins? You measured the...
How Much Square Footage Can a 24,000 BTU Mini Split Cool?
Complete Sizing Guide How Much Square Footage Can a 24,000 BTU Mini Split Cool? You’ve measured your great room. You’ve...
Dual Zone Mini Split Setups: Complete Guide and Cost Breakdown
Complete Guide (2026) Dual Zone Mini Split Setups: Complete Guide and Cost Breakdown Keeping two different rooms comfortable shouldn't mean...