Cooper & Hunter Olivia 12,000 BTU Single Zone Wall Mount, 115V, R454B - Ductless Mini Split Air Conditioner Heat Pump | No Kit









Cooper & Hunter7-Yr Warranty
Product specifications
| Brand | |
|---|---|
| Voltage | |
| SEER | |
| WiFi | |
| Zone | |
| Type | |
| Freon | |
| Compressor |
Pickup available at 3550 Northwest 113th Court
Usually ready in 2-4 days
Why buy this mini split from MiniSplitsForLess
- Free Shipping over $300Ships free to the lower 48 states — flat rate, no surprises at checkout.
- USA-Based Expert SupportReal U.S. HVAC pros help with BTU sizing, refrigerant and install questions.
- Genuine Units & Full WarrantyBrand-new, authorized-dealer equipment backed by the full manufacturer warranty.
- Fast Nationwide ShippingIn stock and ready to ship from U.S. warehouses across all 48 states.
What Stands Out
Sleek Wall-Mount Design
A slim, quiet indoor head mounts high on the wall and delivers 12000 BTU of Olivia-series heating & cooling — modern looks with whisper-quiet operation.
Inverter Efficiency — SEER2 23.2
A variable-speed inverter compressor ramps to match the load instead of cycling on/off, holding SEER2 23.2 on 115V — steady comfort with noticeably lower energy bills.
Right-Sized Coverage
Engineered to heat & cool up to 300–500 sq ft — matched capacity so you never over- or under-size the space.
Olivia Wall Mount
The Cooper&Hunter Olivia Unit mini split AC blends contemporary design with high-performance heating and cooling. Its sleek, modern appearance complements any space while providing efficient climate control for year-round comfort.
Featuring quiet operation, energy-saving technology, and advanced air filtration, it enhances indoor air quality. The unit is ideal for residential and light commercial applications, offering easy installation, minimal maintenance, and reliable performance.
Whether you're looking to cool or heat your space, the Olivia Midnight delivers optimal comfort with style and efficiency, making it a perfect choice for those seeking both function and elegance in their climate control solutions.

Warranty and Tech Support Info
By selecting Cooper&Hunter products for your home or business, you’ll receive expert technical support from heating and cooling specialists, including product manuals, troubleshooting guides, and warranty information.
Warranty terms: The manufacturer provides a Limited Warranty of 7 years for the compressor and 5 years for parts.
Warranty terms
Energy Efficiency
Cooper&Hunter’s Inverter Technology maximizes efficiency and reduces energy costs by adjusting the compressor speed to your specific needs. Experience unparalleled comfort, quieter operation, and longer equipment lifespan. Choose Cooper&Hunter mini split AC for cutting-edge HVAC solutions that deliver optimal performance and reliability.

Main Features
Cooper&Hunter's Olivia Units mini split AC feature sleek, modern design with efficient heating and cooling capabilities. They offer quiet operation, energy-saving technology, and advanced air filtration for improved indoor air quality. Ideal for residential and light commercial use, these units provide easy installation, minimal maintenance, and reliable year-round comfort.

All Accessories Included
With your purchase mini split AC, you receive a comprehensive MiniSplit system. MiniSplits4Less ensures you have everything needed for a seamless installation. Your package includes an Indoor Unit, Outdoor Unit, Remote Control, Manuals, optional LineSet, and a Smartkit (WIFI). We've meticulously thought of every detail to provide you with all the essentials for your installation.

Technical Specifications
Indoor and Outdoor Hyper
| Indoor Model | CH-R006MOLVWM-230VI | CH-R009MOLVWM-230VI | CH-R012MOLVWM-230VI | CH-R018MOLVWM-230VI | CH-R024MOLVWM-230VI | CH-R033HOLVWM-230VI |
|---|---|---|---|---|---|---|
| Power Supply Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 6,000 | 9,000 | 12,000 | 18,000 | 23,000 | 33,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 294.3/225.4/176.8/141.3/NA | 382.6/293.1/194.2/153.0/NA | 382.6/293.1/194.2/153.0/NA | 759.3/530.4/419.1/382.6/NA | 759.3/586.5/419.1/382.6/NA | 829.6/716.6/592.7/447.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 42.0/37.0/32.0/24.0/NA | 42.0/37.0/32.0/24.0/NA | 43.0/37.0/32.0/24.0/NA | 52.5/44.0/40.5/35.2/25.0 | 54.5/49.0/45.3/41.3/27.0 | 56.0/49.5/45.3/41.3/27.0 |
| Dimension (WxDxH) inch | 28.7x7.87x11.81 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.60x9.21x13.27 | 42.60x9.21x13.27 | 52.76x15.16x17.72 |
| Packing (WxDxH) inch | 31.10x10.63x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.40x16.34 | 45.47x12.40x16.34 | 52.76x15.16x17.72 |
| Net/Gross Weight lbs. | 17.64/23.15 | 18.96/24.25 | 18.96/24.25 | 30.42/39.68 | 30.86/40.56 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
| Outdoor Model | CH-RHP06F9-230VO | CH-RHP09-230VO | CH-RHP12-230VO | CH-RHP18-230VO | CH-RHP24-230VO | CH-RHP33-230VO |
|---|---|---|---|---|---|---|
| Power Supply Rated V, Ph, Hz | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range V | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Capacity Range Btu/h | 2,500~11,500 | 3,600~13,500 | 3,600~13,500 | 8,400~20,200 | 16,000~24,500 | 15,000~35,000 |
| Cooling EER2 Btu/h | 16.0 | 15.0 | 13.2 | 13.0 | 12.5 | 11.7 |
| SEER2 Btu/h | 25.3 | 26.0 | 24.0 | 21.7 | 22.3 | 19.5 |
| Rated current A | 3.1 | 4.0 | 4.1 | 9.0 | 8.4 | 14.1 |
| Heating at 47°F COP W/W | 3.80 | 3.63 | 3.63 | 3.54 | 3.05 | 3.22 |
| HSPF4 | 14.6 | 12.5 | 10.5 | 10.8 | 13.3 | 10.5 |
| HSPF5 | 11.2 | 10.1 | 8.0 | 8.8 | 9.6 | 8.3 |
| Heating at 17°F (AHRI) Rated capacity Btu/h | 8,600 | 12,800 | 12,800 | 19,800 | 24,400 | 30,200 |
| Minimum Circuit Ampacity A | 12 | 15 | 15 | 19 | 24.9 | 35 |
| Max.Fuse (Outdoor Unit) A | 15 | 15 | 15 | 20 | 25 | 40 |
| Outdoor Air Flow (Max.) CFM | 1,235.3 | 1,470.6 | 1,470.6 | 1,764.7 | 2,235.3 | 2,235.3 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 53.0 | 56.0 | 56.0 | 59.0 | 61.0 | 63.5 |
| Dimension (WxDxH) inch | 30.12x11.93x21.85 | 31.69x12.99x21.81 | 31.69x12.99x21.81 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.44x19.09x34.84 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 36.02x14.57x24.21 | 36.02x14.57x24.21 | 39.17x15.67x29.13 | 42.91x19.69x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 62.17/67.68 | 72.75/78.70 | 72.75/78.70 | 99.87/107.80 | 130.29/141.31 | 156.87/197.99 |
| Refrigerant Type / Charge oz. | R454B/32.45 | R454B/35.27 | R454B/35.27 | R454B/55.38 | R454B/63.49 | R454B/87.13 |
| Refrigerant Precharge Length # | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. oz/ft | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 | 0.32 |
| Design Pressure PSIG | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
| Max. Pipe Length ft. | 82 | 82 | 82 | 98.4 | 164 | 164 |
| Max. Difference in Level ft. | 49.2 | 49.2 | 49.2 | 65.6 | 82 | 82 |
| Ambient Temperature Cooling °F | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Heating °F | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| NEEP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Indoor and Outdoor Regular
| Indoor Model | CH-R060LVWM-115VI | CH-R09OLVWM-115VI | CH-R120LVWM-115VI | CH-RO9MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R30MELVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated | 115V, 1, 60 | 115V, 1, 60 | 115V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 370/340/265/174/- | 378/340/265/174/- | 378/340/265/174/- | 382/294/194/153/- | 382/294/194/153/- | 759/530/419/382/- | 759/586/419/382/- | 871/716/547/447/- | 871/716/547/447/- |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 44/40/35/26/- | 44/40/35/26/- | 44/40/35/26/- | 45/41/32/24/- | 45/41/32/24/- | 54/49/45/41/27 | 54/49/45/41/27 | 56/52/45/38/22 | 56/52/45/38/22 |
| Dimension (WxDxH) inch | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 45.47x12.01x16.34 | 45.47x12.01x16.34 | 49.57x11.14x14.25 | 49.57x11.14x14.25 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
| Outdoor Model | CH-RES06-115V0 | CH-RES09-115VO | CH-RES12-115VO | CH-RES09-230VO | CH-RES12-230VO | CH-RES18-230VO | CH-RES24-230VO | CH-REL30-230V0 | CH-REL36-230VO |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated V, Ph, Hz | 115, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range V | 103.5-126.5 | 103.5-126.5 | 103.5-126.5 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Rated Capacity Range Btu/h | 2,600~13,000 | 2,600~13,000 | 3,100~19,000 | 2,600~13,700 | 2,600~13,700 | 3,600~20,000 | 9,700~32,700 | 6,800~33,900 | 6,600~36,800 |
| Cooling EER2 Btu/h | 6.9 | 6.9 | 10.0 | 6.9 | 6.9 | 11.0 | 11.0 | 11.0 | 11.0 |
| SEER2 Btu/h | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 |
| Rated current A | 6.9 | 6.9 | 12.0 | 10.0 | 10.0 | 11.0 | 11.0 | 11.0 | 11.0 |
| Heating at 47°F COP W/W | 24.5 | 24.5 | 23.2 | 24.6 | 23.1 | 22.3 | 19.5 | 22.3 | 19.5 |
| HSPF4 | 4,500~12,800 | 4,500~12,800 | 45,00~12,800 | 4,200~14,200 | 4,100~14,400 | 7,600~22,000 | 11,300~32,700 | 11,300~32,100 | 11,400~44,000 |
| HSPF5 | 7.6 | 7.6 | 10.3 | 3.6 | 4.3 | 6.2 | 13.4 | 12.6 | 13.6 |
| Heating at 17°F (AHRI) Rated capacity Btu/h | 8.2 | 8.2 | 7.6 | 9.5 | 8.5 | 8.3 | 7.7 | 7.0 | 7.0 |
| Minimum Circuit Ampacity A | 8,600 | 8,900 | 10,200 | 8,900 | 9,900 | 14,500 | 21,300 | 21,500 | 25,600 |
| Max.Fuse (Outdoor Unit) A | 20 | 20 | 18 | 12 | 18 | 20 | 25 | 30 | 35 |
| Outdoor Air Flow (Max.) CFM | 1,235.3 | 1,235.3 | 1,235.3 | 1,235.3 | 1,235.3 | 1,794.7 | 2,235.3 | 2,235.3 | 2,205.0 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 53.0 | 53.0 | 53.0 | 53.0 | 53.0 | 54.0 | 60.0 | 60.0 | 60.0 |
| Dimension (WxDxH) inch | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 30.12x11.93x21.85 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.24x16.14x31.89 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 39.17x15.67x29.13 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 64.59/70.11 | 92.59/107.60 | 128.17/132.28 | 142.86/154.84 | 150.35/160.27 |
| Refrigerant Type / Charge oz. | R454B/33.51 | R454B/33.51 | R454B/33.51 | R454B/32.45 | R454B/32.45 | R454B/47.97 | R454B/70.55 | R454B/84.66 | R454B/112.88 |
| Refrigerant Precharge Length # | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. oz/ft | 0.16 | 0.16 | 0.16 | 0.16 | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure PSIG | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
| Max. Pipe Length ft. | 82 | 82 | 82 | 82 | 82 | 98.4 | 164 | 164 | 213.2 |
| Max. Difference in Level ft. | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 | 65.6 | 82 | 82 | 98.4 |
| Ambient Temperature Cooling °F | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Heating °F | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| UL | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| AHRI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy Star | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| NEEP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Multiple Control Methods
Cooper&Hunter’s Olivia Midnight Unit mini split AC can be managed with a user-friendly remote control or the Cooper&Hunter optional phone application. Both options offer precise temperature adjustments and optimal climate control for ultimate convenience.
Frequently Asked Questions
What size mini split do I need for my room?
For optimal performance, the Cooper & Hunter Olivia 12,000 BTU mini split is suitable for spaces up to 550 sq ft. This capacity ensures adequate heating and cooling for average-sized rooms.
Can I install a mini split myself?
While some homeowners may attempt DIY installation, it's recommended to hire a professional for the Cooper & Hunter Olivia system to ensure proper setup, especially since it involves refrigerant handling. However, the installation process is straightforward for those with HVAC experience.
Does the mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia mini split comes pre-charged with R454B refrigerant for up to 25 ft of line set, making installation easier. This allows for a quick setup without the need for additional refrigerant filling.
What voltage does a mini split require?
The Cooper & Hunter Olivia operates on a standard 115V electrical supply, which is common in residential settings. This voltage requirement makes it compatible with most home electrical setups.
What warranty does Cooper & Hunter Olivia offer?
The Cooper & Hunter Olivia mini split features a solid warranty that includes a 5-year parts warranty and a 7-year compressor warranty, provided registration occurs within 30 days of purchase. This warranty offers peace of mind for your investment.
What SEER rating do I need for energy efficiency?
The Cooper & Hunter Olivia boasts an impressive SEER rating of 23.2, which is above the minimum efficiency standards set for mini splits. This high efficiency not only reduces energy costs but also qualifies for certain energy rebates and incentives.
Latest News
If you're thinking about turning your home into a smart home, you're not alone.
Mini Split Sale & Clearance Deals: Discounted Heat Pumps
Sale & Clearance Mini Split Sale & Clearance Deals: Discounted Heat Pumps Live Markdowns Factory-Sealed Stock Fast Shipping Cooper&Hunter Olmo...
Small Mini Split Dimensions: Exact Wall Clearances for Tight Spaces
Measured Guide 2026 Small Mini Split Dimensions: Exact Wall Clearances for Tight Spaces When inches matter, Minisplitsforless.com delivers exact clearances...
The 60,000 BTU Reality Check: Installing a 5-Ton Mini Split in a 2,500 Sq Ft Home
Maximum Capacity Climate Control The 60,000 BTU Reality Check: Installing a 5-Ton Mini Split in a 2,500 Sq Ft Home...